Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 05, 2020 SAM #6855
SOURCES SOUGHT

X -- Hays VA Clinic New/Replacing Lease

Notice Date
9/3/2020 12:48:36 PM
 
Notice Type
Sources Sought
 
NAICS
531120 — Lessors of Nonresidential Buildings (except Miniwarehouses)
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25520R0132
 
Response Due
9/30/2020 2:30:00 PM
 
Archive Date
11/29/2020
 
Point of Contact
melissa.brau@va.gov, Melissa Brau, Phone: 913-684-0156
 
E-Mail Address
melissa.brau@va.gov
(melissa.brau@va.gov)
 
Awardee
null
 
Description
The U.S. Department of Veterans Affairs Seeks Expressions of Interest for 7,000 American National Standards Institute/Building Owners and Managers Association (ANSI/BOMA) Office Area (ABOA) Square Feet of Clinical Space in the area of Hays, Kansas. Notice: This advertisement is a notice of a potential opportunity. This advertisement is not a solicitation for offers, nor is it a request for proposals. The purpose of this advertisement is to identify potential sources and suitable locations, and is not intended to pre-qualify or disqualify any potential offers. The Government will not pay for any costs incurred as a result of this advertisement. The Government cannot provide any warranty, expressed or implied, as to the accuracy, reliability or completeness of contents of the furnished information found within this advertisement; Government is under no responsibility to respond to and is unable to answer any inquiries regarding this advertisement. Respondents are advised that the Government assumes no responsibility to award a lease based upon responses to this advertisement. Contracting Office Address: Melissa Brau at 913-946-1133 and Melissa.brau@va.gov , United States Department of Veterans Affairs (VA), Network 15 Contracting Office (NCO15), 3450 South 4th St, Leavenworth Kansas 66048 Description: VA seeks to lease approximately 7,000 ABOA Square Feet of space and 40 parking spaces for use by VA as a VA Clinic (Community Based Outpatient Clinic) in the delineated area explained below within Hays, Kansas. VA will only consider leased space located in an existing building for a build-out lease option. Lease Term: Up to 10 years, 5 year fixed firm and 5 year soft term with termination rights in the soft term. Delineated Area: To receive consideration, submitted properties must be located within the following area described below, which is bound by the following roads, or must front on any of the following boundary lines: Bounded on the North: West 55th Street Bounded on the South: Hwy 183 Bypass/Old Hwy 40/East 8th Street Bounded on the West: Hwy 183 Bypass Bounded on the East: 270th Avenue/Commerce Parkway The attached map of the delineated area is provided for further clarification of the boundaries of the delineated area. SITE CONSIDERATIONS: LOCATION: Facility must be highly visible and located in an area accessible to and from main thoroughfares. PARKING: Adequate, safe lighted parking on site for 13 regular vehicles and 2 handicap vehicle parking spaces shall be provided, with one designated van drop off/loading area. County or City requirements may supersede this specification. ACCESSIBLE PARKING: The accessible parking spaces must be immediately adjacent to the building, meeting local code but not exceeding a distance of 60 feet of entrance. Accessible spaces will be marked with signage by lessor. Entrance to the clinic must be handicap accessible in accordance with ABA. SITE TOPOGRAPHY: Site topography must not have pedestrian traffic grades exceeding 3% slope, 1 ft elevation change in 33 feet. EXTERIOR SIGNAGE: Lessor must provide, approved by the VA, an internally lighted sign with VA logo and words ""Hays Community Based Outpatient Clinic"" on sign a minimum of 4 ft by 8ft legible from main serving road. Sign shall be a minimum of 24 inches above finished grade. Lessor shall develop and provide a complete exterior signage plan to include identification, directional, informational, and regulatory signage. Signage must comply with local municipality s codes and specifications. Careful consideration of the location of monument signs shall be taken to avoid sight triangle encroachment. Lessor shall provide signage on the building/ door. SIGNAGE AND WAYFINDING: A ""wayfinding"" process needs to be designed into every project. Veteran clients, visitors, and staff need to know where they are, what their destination is, how to get there, and how to return to their origination point. Identification, personalization of occupied spaces, and orientation are all to be addressed in the design. Wayfinding is to be thought of broadly as building elements, color, texture, and pattern cues, as well as a coordinated set-up for separate contacted signage and artwork. Lessor shall provide interior signage for and 10 x 2 inch standard aluminum wall sign (holder) for slide in name plates. (VA will purchase name plates). SITE FLAGPOLE: A flagpole will be provided and installed by the Lessor at a location to be approved by the LCO. The flagpole will be 25 foot (minimum height). Flagpole shall include adequate lighting to illuminate flag between dusk and dawn. Flagpole shall be protected from vehicular traffic. Lighting shall be controlled by a photocell device. The flag will be provided by the Government. DRINKING FOUNTAIN: An accessible public, refrigerated, wall hung drinking fountain will be provided in the waiting room or adjacent to the waiting room but not in the corridor. SIDEWALKS: Accessible minimum 5 foot wide sidewalks must be available from parking to entrance. RAMPS: Ramps with over 3% rise, 1:33 slope, must have metal handicap style handrails on both sides. LANDSCAPING: If site topography permits, site will be equipped with bushes and trees. ARCHITECTURAL: FLOORS: Space shall be all on one level with direct parking lot access. Entrance shall be handicap accessible. WALL FINISHES: Painted walls shall be washable semi-gloss; ceilings shall be flat paint finish. All other painted surfaces shall be washable semi-gloss. Low VOC Paint shall be used. Wall coverings shall be washable vinyl or washable paint. Lessor shall repaint entire clinic on a 5-year cycle at no extra cost. Any vinyl covered walls to be refinished at a minimum of every 5 years at lessor s expense. VA to select colors. Vendor shall be responsible for moving and returning of furniture to allow painting and vinyl replacement. Painting/vinyl work shall be done after hours and must be odor free when clinic opens for business. Perimeters of rooms must have rubber or vinyl base cove. All walls shall be finished, no exposed ductwork, conduit or piping. Install chair rail to protect wall services. WALLS: The Lessor shall provide sound dampening insulation in all interior walls. FLOOR FINISH: Carpet tile shall be used. Carpet shall be replaced as necessary, but at a minimum of every 7 years at no cost to the VA. VA to select color. Carpet must have a pile weight of 28 ounces per square yard minimum, a face weight of 28 ounces per square yard and 68 ounces per square yard minimum total weight. Carpet must be continuous filament pile yarn with soil hiding nylon, acrylic/nylon combinations. Carpet must be a maximum 1/2 inch thick, padding is not permitted. Carpet must meet recommended fire/smoke requirements. Vendor responsible for moving and returning furniture during replacement of carpet. Carpet shall be replaced if torn to match existing carpets. All other rooms shall be vinyl tile. Restroom floors and wainscoting shall be ceramic tile. All other floor surfaces to be vinyl tile. Flooring materials shall be free of asbestos containing materials. CEILING FINISH: Ceilings may be sheetrock or lay in tile. Lessor to replace any wet, cut, or damaged ceiling tiles or sheetrock as damage occurs. INTERIOR DESIGN: Color/Finish proposals to be done by a professional interior design service. A minimum of 3 proposals will be provided to the VA each time new finishes are to be reviewed. ASBESTOS / ENVIRONMENTAL HAZARDS: Existing buildings must be asbestos, mold and lead free. ENERGY CONSERVATION: The windows must be double glazed and the walls and roofs must be insulated. Entire facility, including doors and windows must be weather tight. Building insulation and HVAC system must meet DOE recommendations for this region. All appliances shall meet ENERGY STAR® Eligibility Criteria. Building must have evening and weekend set back thermostats. Provide high water-efficient fixtures & appliances. The contractor shall install a weather-resistant barrier wrap, preventing rain from getting into the wall assembly while allowing water vapor to pass to the exterior. The wrap material shall reduce air infiltration into the building. All hot water piping shall be insulated. The building shall be designed to meet the following minimum requirements: under slab/foundation R-3.5, wall R-21, ceiling/roof R-39. Windows and doors shall be rated at the following minimum requirements: U-Factor 0.30, Solar Heat Gain Coefficient 0.31 and low E glass. Each room and hallway will have an occupancy sensor installed, excluding the waiting room. DOORS: Minimum door width is 36 inches. Doors shall be 1-3/4 solid core wood. Exterior entrance door shall be a minimum of 48 inches. Exterior doors and utility rooms to be equipped with automatic door closers. Automatic door openers are required at the main entrance of the clinic and waiting room bathrooms for handicap accessibility. Automatic doors are also required on doors leading from the waiting room to the clinic areas. Doors to the clinic area shall be push pad operated on the clinic side and numerical combination operated on the waiting room side. Exterior doors with removable hinge pins will be retained with set pins or spot welded. A locked door will be required from the main waiting room to access the clinic areas. VA will assign locations of doors after award of contract. DOOR HARDWARE: Doors shall have door handles or door pulls with heavyweight hinges. All doors shall have corresponding doorstops (wall or floor mounted) and silencers. All public use doors and toilet room doors shall be equipped with kick plates. Exterior doors and all common area doors shall have automatic door closers. All building exterior doors shall have locking devices and shall have panic type devices. All hardware shall provide unrestricted egress and be capable of restricting access from the exterior. Properly rated and labeled fire door assemblies shall be installed on all fire egress doors. Doors shall have door handles or door pulls with heavyweight hinges. The Lessor is encouraged to avoid the use of chrome-plated hardware. All doors shall have corresponding doorstops (wall- or floor-mounted) and silencers. Doors designated by the Government shall be equipped with 7-pin, tumbler cylinder locks and strike plates. All door entrances leading into the Government-demised area from public corridors and exterior doors shall have automatic door closers. All locks shall be master keyed. Furnish at least two master keys for each lock to the Government. Any exterior entrance shall have a high security lock, with appropriate key control procedures, as determined by Government specifications. Hinge pins and hasps shall be secured against unauthorized removal by using spot welds or peened mounting bolts. The exterior side of the door shall have a lock guard or astragal to prevent jimmying of the latch hardware. Doors used for egress only shall not have any operable exterior hardware. All security-locking arrangements on doors used for egress shall comply with requirements of NFPA 101. LOCKS: All doors must be equipped with cylinder lock locking hardware and master keyed to match existing VA Best brand, 7 pin locking system. Egress doors must be equipped with panic hardware and meet NFPA requirements for exit. Toilets to be equipped with privacy locks that can be unlocked in emergency with coin from outside. The Lessor will be responsible for providing and installing an automatic locking system with a buzzer to be used on the door from the waiting room to access the clinic area. The Lessor/Owner shall provide all hardware to include the interchangeable cores. The Lessor shall be responsible for the cost of the cores. The Lessor/Owner shall provide a door schedule submittal for VA approval. The key numbering convention will be agreed upon during the design phase. Three master keys will be provided to the government. An exception to the building entrance will be made when the VA is not sole building tenant. The entire space will be keyed the same with the exception of the following spaces: Electrical Closet, OI&T Closet SIGNAGE: Emergency egress signage meeting Life Safety code and The Joint Commission (TJC) is required. All rooms must be equipped with solid plastic identification signs with room function and room number. Unicore brand signage (or approved equal) required in order to match VA system signage-will be approved by COTR. Owner to provide overhead directional signage to restrooms. Emergency egress signage meeting NFPA Life Safety code and Joint Commission is required. All signage must be ABA compliant. For additional information regarding signage see http://www.cfm.va.gov/til/spec.asp PRIVACY: Aural privacy is required between rooms and between rooms and corridor so that private patient information may be discussed without being overheard. For sound privacy, walls of counselor offices and group/conference rooms must be constructed using one of the partition types below and be sound insulated with an approved acoustical insulation. All doors must be solid core and include mechanical door bottom seals where necessary. All doors must be solid core. There is to be a privacy door(s) between the clinic area and the reception/waiting area. Wall construction of STC50. See VHA Program Guide PG-18-3, Topic 11, Noise Transmission Control for further guidance. Partition type options: Option #1 Head Condition: Slab to deck partition extends up to the underside of the deck above, with continuous acoustical sealant. Option #1 Partition Assembly: ½ quiet rock or equal, 3 5/8 metal stud framing, 3 ½ acoustical insulation (roxul or equal), ½ gypsum wall board Option #2 Head Condition: partition extends 12"" above highest ceiling, both sides of wall. 6"" unfaced mineral fiber blanket insulation friction fit for sound deadening (ROXUL or equivalent approved acoustical insulation) Option #2 Partition Assembly: ½ quiet rock or equal, 3 5/8 metal stud framing, 3 ½ acoustical insulation (ROXUL or equal), ½ gypsum wall board Base Condition: Continuous Acoustical Sealant Doors: should be solid core with sound gaskets and sweeps. Door frames should be insulated. Outlet boxes: cover all sides of all tel. & elec. Outlets with 1/4"" thick acoustical sealant before applying gwb. Do not install outlets back to back. To maintain max spacing between outlets on opposite sides of partitions. WINDOW TREATMENT: Windows must be covered with vertical window blinds that utilize traverse rods provided by the Lessor. Blinds that utilize pull cords are not acceptable. Traverse rods shall draw from the center, right or left side. Horizontal blinds are acceptable only for enclosed integrated blinds. Draperies are not acceptable. BATHROOMS: Sinks shall be equipped with soap dispenser provided by the lessor. A shelf and mirror provided by the lessor shall be installed above each sink. Each commode shall have a toilet paper dispenser provided by the lessor installed within easy reach. A coat hook shall be installed on inside face of stall doors. A paper towel dispenser provided by the lessor shall be installed near the sink. All bathrooms shall be equipped with a baby changing station provided by the lessor. All bathrooms shall meet handicap accessibility codes and will include grab bars at commode. The men's toilet shall have a urinal in addition to a commode, if size of bathroom permits. All toilets shall meet handicap accessibility codes and will include grab bars at commode. Metal partitions required at urinals and metal partitions with doors at commodes unless otherwise noted. CORRIDORS: All corridors shall be a minimum of 6 feet wide and shall include VA approved handrails and VA approved lower wall protection. FIRE EXTINGUISHERS: Portable 10 lb. fire extinguishers will be provided, hung and maintained by the VA. Lessor is to install recessed fire extinguisher cabinets at appropriate locations to meet NFPA. COUNTERS: All counter tops shall be solid surface material (ex. Corian type) all exposed edges shall have a minimum ¾ radius (top, bottom, and corners). PATIENT TRAFFIC FLOW IN BUILDING: Building to be arranged such that patients enter immediately into vestibule, then enter waiting room to reception counter and finally enter clinical areas. CANOPIES: Entrance doors will be recessed 3 feet or a minimum of 3 ft by 3 ft rain canopies will be over each entrance door. Vestibule (air lock) must have 2 sets of doors separated by at least 8 feet. Both doors in each set must have an automatic door opener. VESTIBULE: Vestibule shall be ABA compliant. ACOUSTICAL REQUIREMENTS Reverberation Control. Ceilings in carpeted space shall have a noise reduction coefficient (NRC) of not less than 0.55 in accordance with ASTM C 423. Ceilings in offices, conference rooms, and corridors having resilient flooring shall have an NRC of not less than 0.65. Ambient Noise Control. Ambient noise from mechanical equipment shall not exceed noise criteria curve (NC) 35 in accordance with the ASHRAE Handbook of Fundamentals in offices and conference rooms; STC 50 in corridors, cafeterias, lobbies, and toilets; STC 50 in other spaces. Noise Isolation. Rooms separated from adjacent spaces by ceiling high partitions (not including doors) shall not be less than the following noise isolation class (NIC) standards when tested in accordance with ASTM E 336: Group Rooms STC 47-50 Counseling Offices STC 50 The sound resistant enclosures (partitions, doors, duct system) of the spaces listed below shall be designed to suppress generated noise and provide a satisfactory degree of acoustical isolation for adjacent occupied spaces. A minimum Sound Transmission Class (STC) rating of 50 shall be achieved. The required rating may be achieved through the use of construction such as a double layer of GWB on both sides or Quiet Rock product on both sides, slab/slab and/or ROXUL insulation for above ceiling. Alternatively, a gypsum board ceiling or gypsum board lay-in ceiling panels, both with sound attenuation blanket above the ceiling, shall be provided where ducts, pipes, etc., make it impractical to extend sound partitions to slabs or deck above. Where gypsum board ceilings with attenuation blankets are used, the double GWB partitions and sound attenuation blanket shall extend 6"" above the ceiling. Studs shall continue to the floor above. Special attention shall be given to prevent possible flanking paths for noise transmission. Use sound gasketing around doors and door sweeps. In the design of exterior building walls at sites near airports, freeways, or heavy city traffic, consideration shall be given for the control of noise transmission from external sources. UTILITIES: CABLE TV: Lessor shall provide empty 2x4 boxes for cable TV audio/video wall jack for connection to a VA furnished television in the Reception area. A 120 volt duplex electrical outlet will be located adjacent to the cable box outlet. The Lessor shall provide duplex outlet, empty cable box and cable route access. SINKS: The lessor shall provide and install wall-mounted soap dispenser and paper towel dispenser for each sink. EMERGENCY LIGHTING: Must have adequate power failure lighting in corridors and waiting room. Lessor responsible to maintain function of emergency lighting including bulbs, batteries and all other parts. Lights will be periodically tested by VA. Lights will have dual power source (normal power and battery back-up or generator) and automatic activation to illuminate egress route. SECURITY: Security will be provided in compliance with the VA Physical Security Design Manual for a Life Safety type facility. For specific areas in the facility (IT Closet, Medicine room) the requirements of VA Handbook 0730/4 apply. Overall security shall also include deterring loitering or disruptive acts in and around the space during duty hours. Tenant shall have security within the tenant space, separate from that of the general building security. Keys/cipher locks OR key fob/card reader capability for employee access. No public access to the offices will be allowed. Security Alarm Intrusion Detection System Provide a security system, to alarm upon illegal entry or loitering in the leased space and to prevent unauthorized entry 24 hours per day, 7 days per week that alarms locally at the site and to a remote monitoring location. CCTV Monitoring/Surveillance Install twenty-four hour Closed Circuit Television (CCTV) coverage and recording operated internally, and maintained by the Lessor. The Building Security Assessment of the building will determine the exact number of cameras and locations. Time-lapse video recordings (digital storage) are also required and need to have at least 180 days of storage capacity. The DVR for the time-lapse video recordings will be housed in the telecommunications space and be compatible with the current security CCTV system at the main facility. The camera system will be integrated with the intrusion detection system. Interior: The following areas are required to be under camera surveillance: The general waiting area, IT Data Room, Entrance to the Mechanical Room, hallways, common areas, all exits/egress doors for the facility and building perimeter (i.e., parking lots, rear of the building and all applicable areas). Exterior: The following areas are required to be under camera surveillance: Patient and employee parking and all entrances. LIGHTING: Lessor to replace lamps on interior lights. Lessor to provide and replace lamps on exterior lights. Lighting to provide a minimum of 70 foot candles in work areas and 30 foot candles in non-work areas. Building entrances and parking lot to be lighted with high efficiency exterior lighting. HVAC: The heating, air conditioning and ventilating systems shall meet city, state and national codes and be designed to meet ASHRAE minimum recommendations. The repair and maintenance of the HVAC system including replacement/cleaning of filters according to manufacturer recommendations shall be maintained by the lessor. At a minimum, equipment shall be serviced two times per year, once in the fall prior to the heating season and once in the spring prior to the cooling season. Failure of the HVAC system shall be treated as an emergency with response within 3 hours. Equipment must maintain temperature ranges between 70-76 degrees regardless of weather conditions. Bathrooms, housekeeping closet and multipurpose exam room will all include exhaust venting to the outside to create a negative pressure in these rooms. Data room shall have extra cooling supplied, sufficient to keep the room at 70-75 degrees controlled by its own thermostat. Rooms shall have a minimum of 6 air changes per hour. The building will be provided with enough thermostats and controls to adequately control the space. HVAC shall be a certified system and Lessor will provide a room by room listing of supply and return CFM. **The data closet will be provided a separate, thermostatically controlled cooling unit capable of maintaining 70 degrees F with computer equipment producing a 12,000 btu heat load. ELECTRIC: Electric panels must be circuit breaker type with 25% excess capacity. Circuit breakers must be identified as to area served. Bathrooms and other wet locations must be equipped with GFCI outlets. All items must be U.L. approved. Rooms must be equipped with at least one duplex outlet on each of four walls of rooms and an additional outlet for walls longer than 12 feet. Smaller rooms must have at least two outlets. No more than 8 outlets per circuit. Data closet to have at least 4 120V duplex outlets on 2 circuits. Lessor to provide one 120 V duplex in the center of the group clinic rooms, above the ceiling for future projector mounting provided and installed by the VA. Corridors will have outlets at least every 25 feet. All outlets in all rooms to be set ground plug up. All electrical systems shall meet and be in compliance with the National Electric Code (NFPA 70). Standard size ¾ conduit or above shall be used throughout entire space leased by the VA. Flexible whips are permitted only for lighting of type MC Cable and shall be used in accordance with NFPA 70. Outlet placement will be indicated by the VA during design review. CHANGES: As part of the lease the Lessor will provide the VA with a cost per electrical outlet for the Lessor to install electrical outlet additions to the facility beyond the previously listed requirements. FIRE ALARM: Building to be equipped with fire alarm system that meets city, state and NFPA code requirements and remote annunciation to local fire department or monitoring service. Fire alarm testing required by NFPA is the responsibility of the Lessor. Complete testing will be done at least once per year. Copies of all test reports will be sent to the VA COR. At a minimum, there will be pull stations at each exit and smoke detectors in waiting areas, corridors, furnace/HVAC rooms and storage rooms. Strobes/audible devices will be installed as to be visible in all directions and in conference/multipurpose rooms. Fire sprinklers will have tamper and flow alarms and be tested in accordance with NFPA standards. WET AUTOMATIC FIRE SPRINKLER: Building will have an NFPA compliant wet automatic sprinkler system. Building shall be fully sprinklered and contain all necessary fire alarm features. Lessor will be responsible for performing all NFPA required testing and maintenance on the system. UTILITIES: Availability of utilities is the responsibility of the Lessor. The Lessor is responsible for the cost of utility usage (electricity, gas, water, trash and sewage) based on consumption. If the VA area is co-joined to space leased to others, then the Lessor will provide separate metering to measure government usage. The Lessor is required to pay any deposits and hook-up fees relative to utilities. DATA CLOSET REQUIREMENTS: DISTRIBUTION FACILITY: (communications/data closet): The room shall be a minimum of 80 sq. ft. room. The Lessor shall install a 4 foot by 8 foot ¾ inch thick fire retardant plywood board on the wall of the telephone closet for the mounting of equipment. The plywood board should be placed so that stenciling is facing away from the wall to clearly display it. (Ortronics Series or equal). All DMARC equipment should terminate in this room from the exterior point of presence. Fiber should be terminated to ST type connectors. FIBER: All fiber-optic cables, equipment and terminations shall comply with ANSI/EIA/TIA specifications and with specifications in the below table: DATA WIRE: Cable shall be as indicated in the table below. Terminate cable on RJ-45 high density modular 110 patch panels. Each patch panel shall have a channel identification system that allows numbering or labeling of the jacks (A,B= phone; C,D= data). Provide and run the 25 pair cable. Install a minimum 25 pair phone and 4 pair fiber optic cable from the primary Point of Presence (data closet) to all other closets in a multi-level or multi closet system JACKS: Jacks shall be quad with a 4 position faceplate, Category 6A compliant, eight position RJ-45 jack designed for Voice/Data (jacks wired for 568B Category 6A standards), Ortronics Series. Furnish and install two quad jacks for each room, except where site drawings specify otherwise. Locations and number of drops will be determined by the site service drawing provided by the VA. SECURITY: Construct walls deck to deck with no opening to prevent up and over access. The barricade must be with a suitable partition in the interstitial space. Ventilation grills on doors and air circulation ducts which exceed 0/06 m2 (100 square inches) must be reinforced to prevent their removal from outside the room. Other possible access means such as dumbwaiter shafts, roof or wall ventilator housings, etc. must be secured by an appropriate means. Door Construction: Doors are to be of 45mm (1-3/4 in.) solid core hardwood or hollow steel construction. Dutch or half doors are unacceptable. Removable hinge pins on door exteriors must be retained with set pins or spot welded, preventing their removal. Mechanical locking systems. Where mechanical lock systems are used, installed lock sets must allow for a single motion egress. The installation of a high security exit device meeting NFPA Life Safety Code standards is required. If a door is not set in a steel frame, one of the two locks must be a jimmy proof rim dead lock. Doors set in steel frames must be fitted with a mortise lock with a deadlock pin feature. The day lock on the main door must be automatically locking, with a minimum 19mm (3/4 in.) dead bolt and inside thumb latch. Combinations or keys to day locks will be restricted to VA OI & T personnel. Hinges either on inside of closets or if exterior are welded or pinned to prevent removal of hinge bolt. Data closets may not be shared space with any other services such as housekeeping, storage, electrical panels, alarm systems, etc. UTILITIES: Install five 120 volt 20 AMP 4 gang grounded electrical outlets (NEMA 5-20R) in each data closet. Minimum 8 x 10 = 80 square feet. 2 or 4 bulb Fluorescent Electrical light with light switch mounted on inside of the room. HVAC or ventilation sufficient to cool and control humidity for equipment. (If the existing system cannot be zoned to supply individual room control then a separate AC system will be required). Temperature should be maintained between 68-75 degrees with humidity between 20%-60%. OTHER: No water lines may run through or over closet. Room must be protected from weather No windows in door or wall.  (See ISO for possible exceptions) Power equipment for the information system needs to be protected from tampering, damage, and destruction. The breaker box that controls power to the facility including the telecommunications closet is required to be secured. Wire ladder trayswill be located in each hallway and run the entire length of the hallway. All outside of the building wiring will be secured in 2 PVC pipe. The use of J hooks is prohibited. Conduit from the jack to above the firewall shall be a minimum of ¾ . The data closet shall have a ceiling that is hard (fixed) or walls that go from true floor to roof deck to prevent over wall access. Access to the closet will be restricted to include only those persons specifically authorized by the VA-OIT, including facility lessors. MAINTENANCE: JANITORIAL SERVICES AND SUPPLIES: The Lessor shall provide full service janitorial services for the space during business hours for maintaining a clean and orderly space. The Lessor shall maintain the leased premises, including outside areas in a clean condition and shall perform all work and provide supplies and equipment. The Lessor is responsible for interior and exterior cleaning and trash pickup from grounds. The Lessor is responsible for exterior cleaning and maintenance. All janitorial service providers shall undergo a security background check. PEST CONTROL: The Lessor is responsible to exterminate insects, rodents and other pests monthly and when pests are detected in the leased property. Pest spraying must be done so as not to interfere with VA work. Due to sensitive nature of patients, spraying must be odorless and non-irritating. Mechanisms used for pest control are at the approval of the VA in coordination with the COTR. MAINTENANCE: Building equipment and maintenance requirements, interior and exterior, shall be met by the Lessor. The Lessor must have a building superintendent or local designated representative to promptly correct deficiencies or attempt to correct safety deficiencies within 4 hours. Lessor s representative shall be available via pager or cell phone for emergencies. Cosmetic and non-emergent deficiencies must be corrected within two weeks. If no attempt is made to correct the deficiency within the required time frame, the c...
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/9b00fa19940f4f6eb060b7c9063b4dcc/view)
 
Record
SN05787298-F 20200905/200903230204 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.