54 -- Al Jaber Grounds Fuels Tank Support

Notice Date
9/6/2020 8:10:26 AM
 
Notice Type
Solicitation
 
NAICS
332420 — Metal Tank (Heavy Gauge) Manufacturing
 
Contracting Office
FA5703 386 ECONS LGC APO AE 09855 USA
 
ZIP Code
09855
 
Solicitation Number
FA570320Q0044
 
Response Due
9/13/2020 4:00:00 AM
 
Archive Date
09/28/2020
 
Point of Contact
Yeongsoo Jeon, Phone: 3184426913
 
E-Mail Address
yeongsoo.jeon@asab.afcent.af.mil
(yeongsoo.jeon@asab.afcent.af.mil)
 
Description
Self-Contained Aboveground Tanks Statement of Work (SOW) This Statement of Work (SOW) defines the scope for building and delivering a government owned vehicle (GOV) service station Al Jaber Air Base, Kuwait.� As used throughout this SOW, the term �Contractor� refers to the prime contractor to whom this Purchase Order is awarded. WARRANTY: Upon completion and acceptance of the project, the Contractor shall warranty work against defects in workmanship for a period of one year from date of final acceptance. SPECIFICATIONS The Contractor shall build and deliver Four (4) Self Contained Aboveground Tanks with Fuel Dispensers and Account Data Collection System (Fuels Master�a Syntech Systems Product) to Al Jaber Air Base, Kuwait. Each of the four (4) Self Contained Aboveground Tanks will be Fireguard 12,000 gallon double wall tanks on saddles with new single-hose commercially available dispensers, including the following functionality / features at minimum (all components, features, and tank will come prefabricated ready to be fully operational upon delivery with minimal connections [i.e. power and fuel hoses]): Two (2) tanks will be required for automotive gasoline and two (2) for diesel fuel; The dispensers and all components shall be constructed of marine grade and quality materials capable of withstanding high humidity and heat environment of Kuwait; Non-self-contained electric motors and pumping units; Individual meters for each dispensing hose; Lockout capability at each dispensing hose; Inline filtration system capable of sediment removal to 10 mg/l or less; Breakaway device on each hose, designed to retain liquid on both sides of the breakaway point; Sized for passenger vehicle fuel servicing (10 gallons per minute issue flow rate).� For proposal costing purposes, assume that all dispensers will be for passenger vehicles; 208-220 single phase 10 amp per tank; Weather overhang covering Fuels Master and fuels dispenser; 3� Stack Vent (12� above grade); 2� 918 Clock Gauge (read in inches to nearest 1/8 inch) with alarm & standard float for accurate fuel level reading; UL (Underwriters Laboratories) listed fill box for secondary containment; 1� Automatic Shutoff Nozzle, Swivel, and Breakaway ; 18� x 1� Hose and 12� Jumper Hose; 3/4 Horsepower Pump Assembly; Dispenser Single Hose/Single Product with 100:1 Pulsar; Interstitial Leak Gauge and audible alarm; Emergency Shutoff Valve (Shear Valve); Overfill Prevention Valve w/ test mechanism; 4� Ground Level Fill camlock connection; 18� Manway for easy inner tank accessibility; Ladder with Safety Shield and hand rails for fill box; UL 2085 Labeled & Listed; Steel Thickness 1/4� Shell & 5/16� Head; Touch-up paint, Tank Decal Kit, & Owner�s Manual; Provided certified strapping charts (in gallons) to the nearest 1/8 inch intervals; As the service station is unmanned, each dispenser shall be equipped with an inventory control system, following the requirements of UFC 3 460 01 and DLA Energy-P-5.� The current system is equipped with a Syn-Tech FuelMaster Unit (FMU) system enabled with Vehicle Identification Link (VIL) keys and manually connected via an Ethernet cable for downloading and uploading data;� Ensure that all electrical work, including electrical equipment, motors, and wiring, are in accordance with all requirements of NFPA 70, UFC 3-460-01, 3-460-03, and UFGS 26 20 00, as applicable; Delivery to Al Jaber Air Base, Kuwait with access to the base in accordance with local installation access guidance. SPECIFICATIONS AND CODES In addition to the specifications, codes and standards listed the Contractor shall comply with [the most recent edition at the time of this solicitation] all applicable Local, State, and Federal building and life/health/safety codes, to include, but not limited to the following: Unified Facilities Criteria (UFC) Unified Facilities Guide Specifications (UFGS) EM 385-1-1: Safety and Health Requirements Manual 29 CFR 1910, Occupational Safety and Health Administration (OSHA) National Electrical Code (NEC) National Fire Protection Association (NFPA) Steel Tank Institute (STI) SP001: Standard for the Inspection of Aboveground Storage Tanks UL 142: Standard for Steel Aboveground Tanks for Flammable and Combustible Liquids NFPA 30: Flammable and Combustible Liquids Code NFPA 30A: Code for Motor Fuel Dispensing Facilities and Repair Garages NFPA 101: Life Safety Code NFPA 780: Lightning Protection UFC 3-460-01: Petroleum Fuel Facilities ASME IX: Welding and Brazing Qualifications UFGS 33 08 55: Commissioning of Fuel Facility Systems UFGS 33.52.90.00.20:� Welding for POL Service PipingEnd of Statement of Work Please fill the attached amendment�form for the submission of the quote. Also, please send me�specifications, drawings or pictures, and�technical capbility statements of tanks. If you have concerns or questions, please e-mail to yeongsoo.jeon@asab.afcent.af.mil.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/491a8e35c2bf4688be8a077d461c0aef/view)
 
Place of Performance
Address: KWT
Country: KWT
 
Record
SN05788637-F 20200908/200906230133 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.