SOURCES SOUGHT
J -- Sources Sought Fire Suppression Repair
- Notice Date
- 9/16/2020 4:30:15 AM
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
- ZIP Code
- 04330
- Solicitation Number
- 36C24120Q0631
- Response Due
- 9/23/2020 10:00:00 AM
- Archive Date
- 12/22/2020
- Point of Contact
- Joshua.Gallien@va.gov, Josh Gallien, Phone: 413-584-4040 X6460
- E-Mail Address
-
Joshua.Gallien@va.gov
(Joshua.Gallien@va.gov)
- Awardee
- null
- Description
- Department of Veterans Affairs Veterans Health Administration (VHA) Sources Sought Notice Fire Suppression System Repairs This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of your company s offered services and capabilities. The Government will not pay any costs for responses submitted in response to this Source Sought Notice. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the service requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of a capability response that addresses the specific requirement identified in this Sources Sought (please indicate your company DUNS on your capability statement). The Veterans Health Administration (VHA) is seeking a qualified vendor to provide Fire Suppression System Repairs at the VA West Haven Connecticut facility. The standard of services shall be of quality; meeting or exceeding those outlined in the general requirements section as described below. Refer to the General Requirements section below for the requested service description. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. General Requirements: The purpose of this requirement is to repair the Fire Suppression System Identified Deficiencies. Scope The Contractor shall make all required Fire Suppression System deficiency repairs at the VA Connecticut s Healthcare System s West Haven campus identified during the annual inspection. The repairs shall be made in accordance with NFPA codes 13,20,25, and 72. Location of Services: Location of Facility West Haven VAMC 950 Campbell Ave West Haven, CT 06516 Repairs Requested VET Center replace water gong and 4-inch OS & Y valve in main control valve Building 8.5 replace water gong Building 24 repair water gong Building 1 tamper switch needs replacement on 4-inch OS & Y valve, riser #10 Building 1, room SG160 tamper switch needs replacement on 6-inch OS & Y valve Building 1, room SG160 tamper switch needs replacement on 2 ½ inch OS & Y valve Building 1, SPD replace 6-inch flow switch on riser #8 Building 36A tamper switch needed on PIV Building 35 Annex tamper switch needed on PIV Building 2 Entrance and Building 1 West Spring Street Entrance install caps on fire department connections Building 22 Replace 2 ½ inch butterfly valve on anti-freeze loop before the backflow Fire Hydrant near Building 36 replace hydrant, has a broken rod
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/fd00fd70ab8e4587a0ffba591dc71d03/view)
- Place of Performance
- Address: See Sources Sought for details
- Record
- SN05800672-F 20200918/200916230207 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |