SOURCES SOUGHT
Z -- Hills Creek Dam Electrical Reliability Upgrades
- Notice Date
- 10/27/2020 10:52:47 AM
- Notice Type
- Sources Sought
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- US ARMY ENGINEER DISTRICT PORTLAND PORTLAND OR 97204-3495 USA
- ZIP Code
- 97204-3495
- Solicitation Number
- W9127N20R0032
- Response Due
- 11/13/2020 2:00:00 PM
- Archive Date
- 11/28/2020
- Point of Contact
- John Housewright, Phone: 5038084614, Kristina K. Morrow, Phone: 5038084628
- E-Mail Address
-
John.D.Housewright@usace.army.mil, Kristina.K.Morrow@usace.army.mil
(John.D.Housewright@usace.army.mil, Kristina.K.Morrow@usace.army.mil)
- Description
- HILLS CREEK ELECTRICAL RELIABILITY UPGRADES U.S. ARMY CORPS OF ENGINEERS, PORTLAND DISTRICT ISSUED: October 27, 2020 RESPONSES DUE: November 13, 2020 at 2:00 PM PDT THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. This notice does not constitute a commitment by the Government.� All information submitted in response to this announcement is voluntary, and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The proposed NAICS code for this procurement is 238210, Electrical Contractors and Other Wiring Installation Contractors The size standard: $16.5M Federal Service Code: Z2KA, Repair or Alteration of Dams Location of project: Hills Creek Dam, Hills Creek Lake, Oakridge, OR The U. S. Army Corps of Engineers (USACE), Portland District, requires a contractor to replace the existing 4160 V switchgear (including the original air blast main unit breakers with vacuum breakers); replace the existing 480 V double ended-switchgear (including new station service transformers); new powerhouse motor control centers; replacement of powerhouse 480 V CQ panels; the DC system (including new station battery); preferred AC equipment; related protection and controls; new wiring for power, protection, controls, annunciation and ancillaries.� Scope includes a new replacement emergency diesel engine generator intended to support emergency loads to the powerhouse as well as the spillway and respective ventilation and structural modifications and improvements. The anticipated magnitude for this project will be between $5,000,000 and $10,000,000. NO AWARD WILL MADE FROM THIS INITIAL NOTICE. THIS IS NOT AN INVITATION FOR BIDS OR REQUEST FOR PROPOSALS. Submission Instructions: Please send responses with the subject heading �Hills Creek Electrical Reliability Upgrade Sources Sought� to John Housewright, email address: John.D.Housewright@usace.army.mil. CAPABILITY STATEMENT TO SHOW INTEREST AND INTENT: Respondents interested in performing the proposed project as a prime contractor should submit a capability statement for consideration that include the following: A. Offerors' name, address, points of contact with telephone numbers and e-mail addresses. B. DUNS number and CAGE code. C. Firm's small business category and Business Size: Small Business (SB), Small Disadvantaged (SDB), including 8(a) firms, Historically Underutilized Business Zones (HUBZone), Women-Owned Small Business (WOSB), including Economically Disadvantaged Women-Owned Small Business (EDWOSB), and Service-Disabled Veteran-Owned Small business (SDVOSB). D. A Statement of Capability (SOC) stating your skills, experience, and knowledge required to perform the specified type of work as described above. This SOC should be a brief description of your company's capabilities. The potential offerors should provide the magnitude and brief references of relevant work they have performed.� Include a statement detailing any special qualifications and certifications, applicable to the scope of this project, held by your firm and/or in-house personnel including the following; The extent to which the offeror�s statement of capability demonstrates experience working with medium voltage switchgear; and The extent to which the offeror�s statement of capability demonstrates experience working with diesel generators; and The extent to which the offeror�s statement of capability demonstrates experience in vertical construction. E. Indicate whether your company will perform the work directly or intends to subcontract the work. If subcontracting, identify the percentage of work to be subcontracted. Identify the percentage of work your firm may be capable of directly performing. F. Any other information that would assist in determining your company's capability in performing the described construction work. Responses to the Sources Sought will not be returned. Responders are solely responsible for all expenses associated with responding to this Sources Sought. USACE Portland District will not pay for information received in response to this Sources Sought. Do not submit pricing information in response to this Sources Sought. All responses must be submitted in either Microsoft Word or Adobe PDF format no later than 2:00 PM Pacific Time on Friday, November 13, 2020. Do not include proprietary information in your response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Point of Contact for small business questions or assistance is the Portland District Deputy for Small Business, Carol McIntyre at 503-808-4602 or Carol.A.Mcintyre@usace.army.mil.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/c1eb950be0b14f439562cbaf06798a16/view)
- Place of Performance
- Address: Oakridge, OR 97463, USA
- Zip Code: 97463
- Country: USA
- Zip Code: 97463
- Record
- SN05839274-F 20201029/201027230148 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |