MODIFICATION
J -- J�MAINTENANCE, REPAIR, AND REBUILDING OF EQUIPMENT � FIRE FIGHTING, RESCUE, AND SAFETY, FLEET READINESS CENTER EAST, MARINE CORPS AIR STATION CHERRY POINT, NORTH CAROLINA
- Notice Date
- 11/19/2020 3:28:07 PM
- Notice Type
- Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- NAVAL FAC ENGINEERING CMD MID LANT NORFOLK VA 23511-0395 USA
- ZIP Code
- 23511-0395
- Solicitation Number
- N4008521R2504
- Response Due
- 12/21/2020 11:00:00 AM
- Archive Date
- 05/21/2021
- Point of Contact
- ERIC E OVERFELT, Phone: 252-466-2622, Ericka J. Bishop, Phone: 2524664750
- E-Mail Address
-
eric.e.overfelt@navy.mil, ericka.j.bishop@navy.mil
(eric.e.overfelt@navy.mil, ericka.j.bishop@navy.mil)
- Small Business Set-Aside
- 8A 8(a) Set-Aside (FAR 19.8)
- Description
- NAVFAC MIDLANT FEAD Cherry Point North Carolina Request for Proposals (RFP) for: Facility Management, Maintenance, Repair, Alteration, Demolition and Minor Construction on the Fire Protection Systems at the Fleet Readiness Center East (FRCE) aboard Marine Corps Air Station Cherry Point, North Carolina. The work includes, but is not limited to Facility Management to specify the requirements for facility planning and asset management services including, but not limited to, work control, service call reception, Condition Based Maintenance Management (CBMM) / Infrastructure Condition Assessment Program (ICAP) support, Special and MILCON project documentation preparation, Regional Shore Installation Plan (RSIP) support, Basic Facility Requirements (BFR) determination, space management planning, real property records maintenance, real estate management support, and technical library operation. The inventory of equipment includes 157 each Wet Sprinkler Systems, 23 each dry sprinkler systems, 44 each various fire detection and alarm systems, 2 each dry chemical systems, 4 each CO2 systems, 3 each fire pump systems,� 1 each AFFF system, 40 each deluge systems, 12 each dry pipe fire suppression air compressors, and 34 each fire rated doors with fusible links. The current, subject to change fire alarm panel inventory includes 2 each AES 7788 Wireless, 5 each Bosch D7024, 1 each Edwards EST Quick Start, 1 each FCI Zone Panel FC-72, 1 each GameWall Flex 410, 1 each Honeywell Silent Knight 5208, 1 each Honeywell Silent Knight IFP-1000, I each JCI IFC 3030, 7 each Johnson control 640, 1 each Johnson Controls, 1 each Johnson Controls & Transponder 640/XP Series, 1 each Johnson Controls 3030, 1 each Johnson Controls IFC-640, 1 each Johnson Controls JCI IFC-320, 2 each Notifier 320, 2 each Notifier 640, 1 each Notifier AFP-200, 1 each Notifier NFS-320, 1 each Notifier System 5000, 1 each Notifier System 5000s, 1 each Simplex 4001 Zone, 6 each Simplex 4002, 1 each Simplex 4005 Zone, 3 each Simplex 4100ES. The work shall require, at a minimum, the contractor to provide either in-house or contracted staff with the following: � NICET Level III certification in Fire Alarm Systems � NICET Level IV certification in Special Hazards Suppression Systems � NICET Level III certification in Water-Based Fire Protection Systems Layout � NICET Level III certification in Inspection and Testing of Water-Based Systems � Registered Fire Protection Engineer as defined in UFC 3-600-01 A complete list of specifications is included in the solicitation.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/e0a343ac5b904cdcb0981a23e8abef24/view)
- Place of Performance
- Address: Cherry Point, NC 28533, USA
- Zip Code: 28533
- Country: USA
- Zip Code: 28533
- Record
- SN05856655-F 20201121/201119230222 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |