Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 21, 2020 SAM #6932
SOURCES SOUGHT

99 -- Getinge Sterilizers and Associated Maintenance

Notice Date
11/19/2020 11:43:01 AM
 
Notice Type
Sources Sought
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
W40M RHCO-ATLANTIC USAHCA FORT BELVOIR VA 22060-5580 USA
 
ZIP Code
22060-5580
 
Solicitation Number
W91YTZ-21-R-0014
 
Response Due
11/25/2020 11:00:00 AM
 
Archive Date
12/10/2020
 
Point of Contact
Eric G. Jones, Phone: 7325138687, Byron W. Bracey
 
E-Mail Address
eric.g.jones28.civ@mail.mil, Byron.w.bracey.civ@mail.mil
(eric.g.jones28.civ@mail.mil, Byron.w.bracey.civ@mail.mil)
 
Description
1. SCOPE OF WORK: � 1.1 The contractor will provide the purchase and installation of the following types of equipment. � Model������������� Description���������������������������� ����������� ����������� QTY��� ����������� Location SRB400���������� RO System Custom, Poly Filter�������������������� 2��������� ����������� Kimbrough ACC SRB400���������� RO System Custom, Poly Filter�������������������� 2��������� ����������� Rader DC 46-4���������������� Clean/Disnf, Vaxjo���������������������������������������� 1��������� ����������� Rader DC 533HC-E�������� Sterlization, 17� SM�������������������������������������� 1��������� ����������� Rader DC SRB400���������� RO System Custom, Poly Filter�������������������� 1��������� ����������� Site-R 46-4���������������� Clean/Disnf Vaxjo����������������������������������������� 1��������� ����������� Site-R 1.2 The contractor will also provide inspection, preventive maintenance of the following Getinge products: Kimbrough Ambulatory Care Center, BLDG 2480 Llewellyn AveFort Meade, MD 20755 Model������������������������� ����������� Description���������������������������������������� Serial Number 2460RD���������������������� ����������� Clean/Disinfect, Sonic����������� ����������� KRL10136 2460UW�������������������� ����������� Clean/Disinfect, Sonic����������� ����������� KSB11798 433HC������������ ����������������������� Sterilization 17� SM�������������� ����������� URA011921 433HC������������ ����������������������� Sterilization 17� SM�������������� ����������� URA011922 5624��������������������������� ����������� Warming Cabinet, SZ5���������� ����������� URA011957 5624��������������������������� ����������� Warming Cabinet, SZ5���������� ����������� URA011958 733HC������������ ����������������������� Sterilization, 61� DD������������� ����������� URA010164 733HC������������ ����������������������� Sterilization, 61� DD������������� ����������� URA010165 733HC������������ ����������������������� Sterilization, 61� DD������������� ����������� URA010166 8666��������������������������� ����������� Clean/Disinfect, Vaxjo���������� ����������� W50021460 8666��������������������������� ����������� Clean/Disinfect, Vaxjo���������� ����������� W50021461 9027��������������������������� ����������� Clean/Disinfect 9100 HC������ ����������� W50024258 9027��������������������������� ����������� Clean/Disinfect 9100 HC������ ����������� W50024259 CAS-30C������������������� ����������� Boiler������������������������������������������������� GC-3316-P12 CAS-30C������������������� ����������� Boiler������������������������������������������������� GC-3317-P12 HS-333����������������������� ����������� RO Watts RO Mod���������������� ����������� 12333368 HS-333����������������������� ����������� RO Watts RO Mod���������������� ����������� 12333369 SRB400���������������������������������� RO System Custom, Poly Filter�������� TBD Rader Army Health Clinic, Fort Myer, VA Model������������������������� ����������� Description���������������������������������������� Serial Number 570303����������������������������������� HS-333 RO System��������������� ����������� 1133345 46-4���������������������������������������� Clean/Disnf,. Vaxjo��������������� ����������� W50028246 SRB400���������������������������������� RO System Custom, Poly Filter�������� TBD 46-4���������������������������������������� Clean/Disnf, Vaxjo���������������������������� TBD 533HC-E�������������������������������� Sterlization, 17� SM�������������������������� TBD ����������� Kirk Army Health Clinic, 2501 Oakington St. Aberdeen Proving Ground, MD 21005 Model������������������������� ����������� Description���������������������������������������� Serial Number 501645����������������������� ����������� WHMS-450-PT Wall������������ ����������� 11-10441 433HC������������ ����������������������� Sterilization 17� SM�������������� ����������� URA011448 46-4���������������� ����������� ����������� Clean/Disinfect, Vaxjo���������� ����������� W50029860 Site-R, 450 Harbourgh Valley Rd. Fairfield, PA 17320 Model������������� ����������� ����������� Description���������������������������������������� Serial Number 422HC������������ ����������������������� Sterilizer�������������������������������� ����������� 03H04124 SRB400���������� ����������� ����������� Watts RO������������������������������� ����������� G140160 46-4���������������������������������������� Clean/Disnf, Vaxjo���������������������������� TBD SRB400���������������������������������� MOD�������������������������������������������������� TBD 2. GENERAL REQUIREMENT: for full service agreement on the Getinge Sterilizer. This Agreement includes Parts, Labor, and Travel. 2.1. For On-site Repairs: (a) Contracted services are to be performed during the time period of 01 October and - 30 September. Contractor is required to respond within one hour and be on site within 24 hours during normal duty hours, 7:30AM through 4:30PM. ������� ������� (b) Contractor's service representative shall report in person or telephonically notify the maintenance manager, Building No. 2480, Telephone No. 301-677-8407 or 8056, prior to commencing services during normal duty operating hours, 7:30AM through 4:30PM. During other than normal operating hours, the contractor's representative shall report to the Administrative Officer of the Day (AOD) for the specific location. ������������� (1) The government and the contractor�s service representative will exchange hazard communication information before the commencement of any repair."" ������������� ������������� (2) When required, the contractor�s service representative will comply with the Office of Safety and Health Administration (OSHA) lockout/tag-out standards while performing maintenance on equipment."" ������������� (3) ""Upon completion of services by the contractor�s service representative, a written service report shall be provided to the maintenance manager or the AOD. The service report shall provide detailed information regarding the cause of the equipment malfunction and corrective action taken. Include, at a minimum, the time required to complete the work, price of labor (hourly rate), and a list of parts replaced with part numbers and prices for each part."" ������������� (4) ""In the event all information is not available to the contractor's service representative when services are performed, the initial service report shall include all available information. The contractor shall provide the balance of the required information to the maintenance manager no later than 10 days after services are completed."" ������������� (5) Contractor�s service representative will be factory trained and have a minimum of two years of experience working on the contracted equipment."" ������������� (6) Contractor must furnish all software upgrades issued by the equipment manufacturer."" ������������� (7) Contractor shall have access to all necessary diagnostic software (if applicable). ������������� (8) Contractor shall use only new or OEM refurbished repair parts."" ������������� ������������� (9) ""Required forms and extracts from pertinent directives will be furnished to the contractor�s service representative by the government."" 2.2 Vendor Must: Be Steris authorized dealer or Steris factory trained hospital Bio-Med Engineer to provide service for any Steris products. Bio-Med Engineers must possess the ability and expertise to maintain Steris equipment through preventive maintenance agreements assuring that Steris manufactured equipment continues to operate in compliance with Original Equipment Manufacturer (OEM) specifications. Possess Steris designed, developed and manufactured software. These are proprietary products. Possess replacement parts that are manufactured or marketed by Steris Corporation and are compliant with original equipment manufacturer specifications. These parts are not available from other sources. 3. REMOVAL OF EQUIPMENT: The contractor shall not remove any equipment from the Government work site without prior written approval of the COR or his/her designated representative. 4. UTILITIES: The government will furnish the contractor all reasonable amounts of electrical power and other utilities necessary to perform the above services called for under this contract. 5. SPECIAL WORKING CONDITIONS: All equipment, parts, materials, and services supplied by the contractor shall conform to the applicable Safety and Health Standards as indicated in the current code off Federal Regulations, Title 29, Chapter XVII, and paragraph 1910, Occupational Safety Health Act of 1970.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/449a120739004675a6be8443179712db/view)
 
Place of Performance
Address: Fort George G Meade, MD 20755, USA
Zip Code: 20755
Country: USA
 
Record
SN05857501-F 20201121/201119230228 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.