Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 12, 2021 SAM #7015
SOLICITATION NOTICE

Z -- Saginaw Primary Care AHU Upgrade - 655-20-505: replace failing equipment and upgrade control components on the existing air handling system that serves the Primary Care area of Building 1.

Notice Date
2/10/2021 7:47:53 AM
 
Notice Type
Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25020R0235
 
Response Due
2/26/2021 11:00:00 AM
 
Archive Date
03/13/2021
 
Point of Contact
Bruce Frierson, Phone: 19893214491, Richmond L McCloud, Phone: 7348453802
 
E-Mail Address
bruce.frierson@va.gov, Richmond.McCloud@va.gov
(bruce.frierson@va.gov, Richmond.McCloud@va.gov)
 
Small Business Set-Aside
SDVOSBS Service-Disabled Veteran-Owned Small Business (SDVOSB) Sole Source (FAR 19.14)
 
Description
This project is at the Aleda E. Lutz VA Medical Center located at 1500 Weiss Street in Saginaw, Michigan and is to replace failing equipment and upgrade control components on the existing air handling system that serves the Primary Care area of Building 1. The air handling unit is a Trane model made up of six (6) modular sections consisting of the mixing box with filter section, internal face and bypass section, heating coil section, access section, cooling coil section, and supply fan section. The return air is ducted to the air handling unit by a Trane 7.5 hp centrifugal belt driven return fan with 27� wheel. There is also outside air ducted to the air handler and exhaust air ductwork attached to the return ductwork. The cooling coil is direct expansion (DX) supplied by a Trane 30 ton air cooled condensing unit and the heating coil is supplied from the heating hot water system. The condensing unit, cooling coil, heating coil, return fan, and return air, outside air, and face and bypass dampers have had issues due to age and are needing replacement. Damper actuators and the heating hot water control valve are pneumatic and need upgrading to electronic.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/529b911205db4e04bbb5a281110d0bff/view)
 
Place of Performance
Address: Saginaw, MI 48602-5251, USA
Zip Code: 48602-5251
Country: USA
 
Record
SN05913358-F 20210212/210210230114 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.