Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 28, 2021 SAM #7088
SOLICITATION NOTICE

54 -- GMUG National Forest Prefabricated Glue Laminated Bridge Deck

Notice Date
4/26/2021 1:03:36 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
321992 — Prefabricated Wood Building Manufacturing
 
Contracting Office
USDA FOREST SERVICE COEUR D ALENE ID 83815 USA
 
ZIP Code
83815
 
Solicitation Number
1240LQ21Q0040
 
Response Due
5/18/2021 4:00:00 PM
 
Archive Date
05/28/2021
 
Point of Contact
Richard Maxted, Michael Lucas
 
E-Mail Address
richard.maxted@usda.gov, michael.j.lucas@usda.gov
(richard.maxted@usda.gov, michael.j.lucas@usda.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
General Description Furnish all bridge components for longitudinal glued?laminated, treated timber slab bridges using structural lumber and timber of the required stress and grade. The furnished structure shall meet the following requirements: Design Load HS20?44 with allowable deflection of L/425. Useable Width 10�?0� Minimum (inside curb face to inside curb face) Span Length 19�?0� Centerline Bearing to Centerline Bearing 1. The superstructure shall consist of six (6), longitudinal, glued laminated panel components. 2. The structure shall be furnished with glued laminated timber sills capable of supporting the superstructure on native or minimally improved ground. Sills shall be designed to support the structure and loads with a maximum soil bearing pressure of 3000 psf. Sills shall be a minimum of 6in. depth by 12in. wide and 12ft. long. 3. All angles and hardware necessary for slab to sill connection shall be provided by supplier. 4. Glulam curb and curb blocks shall be a total of 22in. from the top of the curb to the top of the glulam deck. The curbs (2) should be 10 � in. x 6in. (T) x 20ft. (L) and the curb blocks (8) should be 10 � in. x 16in. (T) x 2ft. 4in. (L). 5. Panel stiffeners shall be designed by the manufacturer. 6. All glued laminated timber components shall be pre?cut and pre?bored.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/4ac92965566241db962d04c2d98dcc44/view)
 
Place of Performance
Address: Telluride, CO 81435, USA
Zip Code: 81435
Country: USA
 
Record
SN05983109-F 20210428/210426230112 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.