47 -- Insulated Duct 8""

Notice Date
8/25/2021 8:47:56 AM
 
Notice Type
Solicitation
 
NAICS
332919 — Other Metal Valve and Pipe Fitting Manufacturing
 
Contracting Office
DLA MARITIME - NORFOLK PORTSMOUTH VA 23709-5000 USA
 
ZIP Code
23709-5000
 
Solicitation Number
SPMYM121Q0102
 
Response Due
9/1/2021 9:00:00 AM
 
Archive Date
09/16/2021
 
Point of Contact
Liz Jackson
 
E-Mail Address
melba.jackson@dla.mil
(melba.jackson@dla.mil)
 
Description
DUCT, INSULATED, 8"". 1: ALL INSULATED DUCT SHALL BE PROVIDED IN TWENTY FIVE FOOT LENGTHS. 2: ALL INSULATED DUCT SHALL BE PROVIDED WITH CUFFED ENDS THAT ARE A MINIMUM OF (THREE) 3"" AND A MAXIMUM OF (SIX) 6"". 3: THE COLOR OF THE INSULATED DUCT MAY BE BLACK, BLUE, SILVER, OR GRAY. THE INSULATED DUCT WILL NOT BE YELLOW, MAGENTA, RED, OR CONTAIN ANY OF THESE COLORS. 4: THE INSULATED DUCT SHALL BE CAPABLE OF WITHSTANDING TEMPERATURES RANGING FROM THIRTY-TWO (32) DEGREES FAHRENHEIT TO TWO HUNDRED FIFTY (250) DEGREES FAHRENHEIT. 5: THE INSULATED DUCT SHALL BE REINFORCED WITH A STEEL HELIX WOUND WIRE. 6: THE INSULATED DUCT SHALL MEET OR EXCEED UL-94-0 FOR FIRE RETARDANCY. 7: THE INSULATED DUCT SHALL BE FIRE RETARDANT PER FEDERAL TEST METHOD AND THE RESULTS SHALL MEET OR EXCEED THE CRITERION GIVEN IN PARAGRAPH 3.3.9.3 OF MIL-H-18158E. (NOTE: REMAINDER OF MIL-H-18158E IS NOT APPLICABLE.) 8: THE INSULATED DUCT SHALL BE NEOPRENE COATED COTTON OR POLYESTER FABRIC, INTERIOR AND EXTERIOR AND MUST BE WEATHERPROOF IN ORDER TO PREVENT THE SATURATION OF THE INSULATING MATERIAL. 9: THS INSULATED DUCT SHALL HAVE A ""R"" FACTOR RATING OF 0.7 MINIMUM AND 1.4 MAXIMUM. 10: POUNDS OF FORCE REQUIRED TO CRUSH ONE FOOT OF DUCT TO 1/2 OF ITS DIAMETER SHALL BE 20 OR GREATER. 11: a) THE MANUFACTURERS NAME AND DATE OF MANUFACTURE SHALL BE PRINTED ON EACH LENGTH OF INSULATED DUCT. b) DUCTS SHALL BE MAKED �FR� OR FIRE RESISTANT BY THE MANUFACTURER. MARKS SHALL BE PLACED AT EACH END AND AT LEAST IN TWO OTHER PLACE EQUALLY SPACED ALONG THE LENGHT OF THE DUCT. c) MARKINGS SHALL BE IN CONTRASTING PERMANENT INK, IN LETTERS AND NUMBERS THREE-QUARTERS (3/4"") TO ONE (1"") INCH IN HEIGHT. 12: REQUIRED PRODUCT FROM FLEXAUST (2 98683) ARTIC DUCT VII 8� x 25�. ANY OTHER MANUFACTOR BRANDED PRODUCT WILL NEED TO PROVIDE A TWO (2) FOOT SAMPLE OF INSULATED DUCT WITH EACH BID PROPOSAL. THIS REQUIREMENT MAY BE WAIVED IF THE CONTRACTOR HAS PROVIDED AN APPROVED SAMPLE PREVIOUSLY.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/7dbb072f4b5c4900812d386a4dc4563d/view)
 
Place of Performance
Address: Portsmouth, VA 23709, USA
Zip Code: 23709
Country: USA
 
Record
SN06110999-F 20210827/210825230132 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.