SOURCES SOUGHT

65 -- Supplies - Defibrillators - Cincinnati

Notice Date
1/26/2022 9:14:38 AM
 
Notice Type
Sources Sought
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25022Q0254
 
Response Due
1/28/2022 9:00:00 AM
 
Archive Date
05/07/2022
 
Point of Contact
Kellie Konopinski, Contracting Officer, Phone: 734-222-4330
 
E-Mail Address
Kellie.Konopinski@va.gov
(Kellie.Konopinski@va.gov)
 
Awardee
null
 
Description
UPDATED Defibrillator Requirements FDA 510(k) approval Biphasic defibrillation Heart rate alarm If device has wireless capability it must meet the appropriate Federal Information Processing Standard (FIPS), FIPS 140-2, to ensure compliance to Federal encryption, algorithm, and risk management requirements. Provide certification number with response if applicable. Ability to have step sequence for shocks. Unit displays shocked joule levels and will advance as required Low battery indicator Ability to toggle between manual and automatic external defibrillator (AED) modes for non ACLS trained staff Provides audible alerts for users Pacing capabilities should include fixed and demand Demand pacing mode should be able to recognize intrinsic heart rhythm Pacing rate should range from 40 to at least 170 pulses per minute Parameters to display and monitor: End tidal carbon dioxide (EtCO2) / capnography Pulse oximetry Non-invasive blood pressure Output current for transcutaneous pacing must range between 0 and at least 140 milliamps Printer for code summary should have the ability include but not limited to: ECG waveform Annotated events, like medication administration or defibrillation Time and date Lead configuration must include: I II III aVR aVF aVL Device must have the ability to convert to pediatric Capable of defibrillation completion in less than 2 minutes, including pediatric defibrillation Device must have the ability to alert staff of compression quality to include depth, rate and chest recoil if this is done through an add-on product, please include add-on product in quote. Accessories to be included in purchase: Disposable Pads Paddles Adaptors Non-invasive blood pressure cuff Ability to use Philips bedside monitors accessories, like ECG leads, blood pressure cuff, pulse oximetry and invasive cable monitoring Ability to filter artifact to display underlying rhythm of patient SERVER (if applicable): Must be compatible with Windows 2016 or newer Ability to be virtualized if Cincinnati VAMC chooses to virtualize server Must have RAM provided for optimal performance Must provide anti-virus and malware software
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/cbc289325b7840118c0519d77a5343ad/view)
 
Place of Performance
Address: Department of Veterans Affairs Cincinnati VA Medical Center 3200 Vine St., Cincinnati, OH 45220, USA
Zip Code: 45220
Country: USA
 
Record
SN06225824-F 20220128/220126230110 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.