SAMDAILY.US - ISSUE OF MARCH 09, 2022 SAM #7404
SOLICITATION NOTICE

12 -- W25G1V22Q0074 Sprinkler System Upgrade

Notice Date
3/7/2022 6:42:25 AM
 
Notice Type
Solicitation
 
NAICS
333999 — All Other Miscellaneous General Purpose Machinery Manufacturing
 
Contracting Office
U S ARMY DEPOT TOBYHANNA TOBYHANNA PA 18466-5079 USA
 
ZIP Code
18466-5079
 
Solicitation Number
W25G1V22Q0074
 
Response Due
3/25/2022 11:00:00 AM
 
Archive Date
04/09/2022
 
Point of Contact
Brian Dionysius, Phone: 5702366530, Robert J Dombroski, Phone: 570-615-6442
 
E-Mail Address
Brian.K.Dionysius.civ@army.mil, robert.j.dombroski.civ@army.mil
(Brian.K.Dionysius.civ@army.mil, robert.j.dombroski.civ@army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
PLEASE REFER TO SOW FOR A DETAILED DESCRIPTION 1. GENERAL 1.1 Overview: Provide all Plant, Labor, Materials, Licenses, Permits, Equipment, Supervision and Management to complete the design and construction services associated with the Building 221 (Teen CDC) sprinkler upgrade. Any and all exceptions shall be in writing and labeled as such. Design services shall include site evaluations, design concept meetings and concept drawing reviews, preparation of construction specifications, construction drawings, and requests for information and construction cost estimates. Area specific details are included on the provided building drawing. Dimensions and depictions on drawing are to be field verified by potential bidders as Tobyhanna Army Depot is not responsible for accuracy of provided drawings. The sprinkler system will be designed in conformance with the latest edition of Unified Facilities Criteria (UFC) 3-600-01, National Fire Protection Association (NFPA) 13 and American Society of Sanitary Engineering (ASSE) 1015. All installed equipment shall be labeled by Underwriters Laboratories (UL) or another U.S. recognized testing agency. The equipment will be acceptance tested per UFC. The fire suppression system shall be Water-Based Dry-Piped throughout the entire structure. The building consists of a basement, living quarters, and attic (three (3) floors). A full analysis shall be conducted to determine the sprinkler main is adequately sized to allow the sprinkler system to provide full guaranteed coverage throughout the building. Mechanical rooms, electrical rooms and fire sprinkler riser rooms shall be classified as �HC-2�. A hydrant flow test will be required. UFC requires schedule 40 steel pipe, 12 pounds per square inch (psi) loss through the back flow and 500 Gallons per minute (GPM) hose stream, which all increase the overall system hydraulic demand. 1.2 Site Visit: In order to gain an understanding of the Bldg. 221 sprinkler project, we suggest that potential bidders attend a scheduled site visit. 1.3 Key Elements: It is the Contractor�s responsibility to relocate any and all items that may interfere with the construction of the new sprinkler system. Example; conduits, gas piping. � Amendment 0001 was added to the attachments with the following change: The reason for this amendment is to change the site visit date from Tuesday, March 15th, 2021 to Tuesday, March 15th 2022.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/ecede1712fe04dbda4b0bbff03eeeedc/view)
 
Place of Performance
Address: Tobyhanna, PA 18466, USA
Zip Code: 18466
Country: USA
 
Record
SN06259031-F 20220309/220307230055 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)