SOLICITATION NOTICE
12 -- W25G1V22Q0074 Sprinkler System Upgrade
- Notice Date
- 3/7/2022 6:42:25 AM
- Notice Type
- Solicitation
- NAICS
- 333999
— All Other Miscellaneous General Purpose Machinery Manufacturing
- Contracting Office
- U S ARMY DEPOT TOBYHANNA TOBYHANNA PA 18466-5079 USA
- ZIP Code
- 18466-5079
- Solicitation Number
- W25G1V22Q0074
- Response Due
- 3/25/2022 11:00:00 AM
- Archive Date
- 04/09/2022
- Point of Contact
- Brian Dionysius, Phone: 5702366530, Robert J Dombroski, Phone: 570-615-6442
- E-Mail Address
-
Brian.K.Dionysius.civ@army.mil, robert.j.dombroski.civ@army.mil
(Brian.K.Dionysius.civ@army.mil, robert.j.dombroski.civ@army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- PLEASE REFER TO SOW FOR A DETAILED DESCRIPTION 1. GENERAL 1.1 Overview: Provide all Plant, Labor, Materials, Licenses, Permits, Equipment, Supervision and Management to complete the design and construction services associated with the Building 221 (Teen CDC) sprinkler upgrade. Any and all exceptions shall be in writing and labeled as such. Design services shall include site evaluations, design concept meetings and concept drawing reviews, preparation of construction specifications, construction drawings, and requests for information and construction cost estimates. Area specific details are included on the provided building drawing. Dimensions and depictions on drawing are to be field verified by potential bidders as Tobyhanna Army Depot is not responsible for accuracy of provided drawings. The sprinkler system will be designed in conformance with the latest edition of Unified Facilities Criteria (UFC) 3-600-01, National Fire Protection Association (NFPA) 13 and American Society of Sanitary Engineering (ASSE) 1015. All installed equipment shall be labeled by Underwriters Laboratories (UL) or another U.S. recognized testing agency. The equipment will be acceptance tested per UFC. The fire suppression system shall be Water-Based Dry-Piped throughout the entire structure. The building consists of a basement, living quarters, and attic (three (3) floors). A full analysis shall be conducted to determine the sprinkler main is adequately sized to allow the sprinkler system to provide full guaranteed coverage throughout the building. Mechanical rooms, electrical rooms and fire sprinkler riser rooms shall be classified as �HC-2�. A hydrant flow test will be required. UFC requires schedule 40 steel pipe, 12 pounds per square inch (psi) loss through the back flow and 500 Gallons per minute (GPM) hose stream, which all increase the overall system hydraulic demand. 1.2 Site Visit: In order to gain an understanding of the Bldg. 221 sprinkler project, we suggest that potential bidders attend a scheduled site visit. 1.3 Key Elements: It is the Contractor�s responsibility to relocate any and all items that may interfere with the construction of the new sprinkler system. Example; conduits, gas piping. � Amendment 0001 was added to the attachments with the following change: The reason for this amendment is to change the site visit date from Tuesday, March 15th, 2021 to Tuesday, March 15th 2022.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/ecede1712fe04dbda4b0bbff03eeeedc/view)
- Place of Performance
- Address: Tobyhanna, PA 18466, USA
- Zip Code: 18466
- Country: USA
- Zip Code: 18466
- Record
- SN06259031-F 20220309/220307230055 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |