Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 29, 2022 SAM #7455
SOLICITATION NOTICE

65 -- Diode Laser System

Notice Date
4/27/2022 2:04:50 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
W40M USA HLTH CONTRACTING ACT JBSA FT SAM HOUSTON TX 78234-0000 USA
 
ZIP Code
78234-0000
 
Solicitation Number
W81K00-22-Q-0085
 
Response Due
5/4/2022 11:00:00 AM
 
Archive Date
05/19/2022
 
Point of Contact
Kimberly Macias, Emerita Torres
 
E-Mail Address
kimberly.r.macias.civ@mail.mil, emerita.torres.civ@mail.mil
(kimberly.r.macias.civ@mail.mil, emerita.torres.civ@mail.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6 and FAR Part 13 Simplified Acquisition Procedures, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The solicitation number is W81K00-22-Q-0085 and is issued as a Request for Quote (RFQ).� This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2022-045 and Defense Federal Acquisition Regulation Supplement Publication Notice (DPN) 20220318. � This solicitation is for a VenaCure Pro Laser System and accessories for William Beaumont Medical Center, Fort Bliss, TX.� The delivery date is 20 June 2022. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 with a size standard of 1,250 employees.� This procurement is being conducted as a Small Business Set Aside.� All eligible businesses may submit an offer, which will be considered. Offers are due by 4 May 2022, at 1:00 PM, Central Standard Time.� The point of contact is Ms. Kimberly Macias at (210) 221-6365 or kimberly.r.macias.civ@mail.mil. Offers shall be submitted via e-mail.� Questions shall be submitted via e-mail not later than 29 April 2022.� No questions will be entertained after this date. This is a ""brand name or equal"" solicitation.� The brand name description of the products are based on VenaCure 1470 Pro Laser System with Dispenser or Equal.� The salient characteristics are as follows: Salient Characteristics ������������������������������������� VenaCure 1470 Pro Laser System or Equal ����� Quantity: 1 each This equipment is used to treat venous insufficiency. This equipment is the power generator required to treat venous insufficiency. The generator attaches to disposable fiber-optic catheters. This equipment is a water- specific laser which targets water as the chromophore to absorb the laser energy which efficiently heats the vein endothelial cells with little chance of collateral damage. It is the standard of care for treating venous insufficiency for vascular applications. Required characteristics: Must be FDA approved Voltage 120 Mobile and can be used in different settings Must provide 2 each of operator manuals and service manuals Technical Specifications Characteristics: General Specifications Product category - Laser for vascular applications Power Supply - 100-240 Vac; 50/60Hz; 350VA Type of protection against electric shock - Class I Degree of liquid ingress protection - IP 20 (Not protected) Degree of electric shock protection Type CF Continuous Mode of operation Dimensions 196 mm(H) x 378mm(W) x 379 mm(D) Weight between 22-25 lbs (10 -11kg max) Operating temperature 50� - 104� F (10� - 30� C) Storage/transport temperature Min. 32� F / max. 130� F (+ 5� C / max. 40� C) Humidity - 30% - 85% non-condensing Pressure from 800 hPa to 1060 hPa Cooling system - Air cooled Max noise (dB) 60 dB Fuse 2 x T4AH 250V Laser Safety Goggles - 3 pair total Laser characteristics Type of Laser - Diode laser Wavelength - 1470 nm � 20nm Maximum Power 15W Operating mode CW, pulsed Pulse duration Up to 10000 ms Pulse pause Up to 2500 ms Repetition Rate Up to 2000 Hz Beam divergence 220 mrad Beam transmission - Optical Fiber Aiming Beam 635 nm, <4mW, class 3R MPE (W/m2) 1000 NOHD (m) 0,31 OD 1 Exposure Time (s) 100 Training: Training for William Beaumont nursing/technical staff not to exceed 50 personnel Training for two William Beaumont clinical engineers Delivery Requirements: Seller must notify Property Warehouse and/or Contracting Officer Representative 3-business days before delivery of equipment Contract number must be clearly displayed on all shipping labels and displayed on outside of package Seller must provide delivery/tracking information. Signature required for delivery NOTE: NO Grayed or refurbished items NO partial orders allowed. Vendor is responsible for shipping to delivery address listed in contract.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/9ee39466723e4090b0a5d72099c9f577/view)
 
Place of Performance
Address: Fort Bliss, TX 79918, USA
Zip Code: 79918
Country: USA
 
Record
SN06310127-F 20220429/220427230102 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.