Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 12, 2022 SAM #7468
SOLICITATION NOTICE

65 -- CROMA Advanced Energy Generator and Accessories

Notice Date
5/10/2022 8:55:31 PM
 
Notice Type
Presolicitation
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
261-NETWORK CONTRACT OFFICE 21 (36C261) MATHER CA 95655 USA
 
ZIP Code
95655
 
Solicitation Number
36C26122Q0593
 
Response Due
5/18/2022 5:00:00 PM
 
Archive Date
06/02/2022
 
Point of Contact
Dennis Salmonsen, Contract Specialist, Phone: 916-923-4928
 
E-Mail Address
dennis.salmonsen@va.gov
(dennis.salmonsen@va.gov)
 
Awardee
null
 
Description
This Notice of Intent is provided to advise that the Government intends to solicit and negotiate a Sole Source, Firm-Fixed-Priced, Purchase Order, with only one (1) source, Creo Medical Inc. The procurement is for the a CROMA Advanced Energy Generator and accessories. This contract action is for supplies for which the Government intends to solicit and negotiate with only one (1) source under the authority of FAR 13.501(a)(1)(ii) and 41 USC §1901, only one (1) will meet the Government s needs. Only one (1) source is capable of responding due to the unique or specialized nature of the supplies and/or services. Interested persons may identify their interest and capability to respond to the requirement. The applicable NAICS Code is 339113 and the size standard is 750 employees. 1. SCHEDULE OF PROPOSED CLIN. *****all line-items are considered Brand Name or provide your Equal substitute for the purpose of market research.****** ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 1.00 EA __________________ __________________ 7-EMR-050 - CROMA Advanced Energy Generator LOCAL STOCK NUMBER: 7-EMR-050 0002 1.00 EA __________________ __________________ 2-PG1-132 - CROMA Generator Foot Switch LOCAL STOCK NUMBER: 2-PG1-132 0003 1.00 EA __________________ __________________ 7-RS2-030 - Speedboat Inject LOCAL STOCK NUMBER: 7-RS2-030 0004 5.00 EA __________________ __________________ 7-RS2-210 - CROMA Interface Cable LOCAL STOCK NUMBER: 7-RS2-210 GRAND TOTAL ________________ Salient Characteristics Brand Name Item: CREO Medical CROMA Advanced Energy Generator Essential/significant physical, functional, or performance characteristics. Compatibility The product is compatible with National VA standards for electrosurgical generators Dimensions Height 165 mm ± 5 mm Width 400 mm ± 5 mm Depth 458 mm ± 5 mm Weight 35 lb / 16 kg Industry Standard The industry standard should include the following characteristics for electrosurgical generators: Medical grade electrical system Adaptive bipolar radiofrequency for smooth cutting without changing settings and providing clear margins Microwave energy for coagulation with controlled spread and depth of penetration Injection needle for on-demand submucosal lift without constant device changes All in one ability to cut, inject, and coagulate Purpose To cut, inject, and coagulate during electrosurgical dissections in endoscopic procedures Governing Body or Organization N/A Complete generic identification Generic cautery unit identification: Electrosurgical unit Ability to use devices that can work through an endoscope Provides microwave coagulation Provider s electrocautery Integrated injection needle Novel 1:1 rotation of instruments Bipolar Cutting of mucosal and submucosal tissue Instruments can provide all in one injection, cautery, and coagulation Applicable model/make/catalog number CROMA Advanced Energy Generator 7-EMR-050 Manufacturer name Creo Medical 2. DELIVERY OF ITEMS The address is with FOB Destination shipping: VA Palo Alto Healthcare System 3801 Miranda Ave. Palo Alto, CA 94304 This notice of intent is not a request for competitive quotes and no solicitation will be made available. Any responses received will only be considered for the purposes of determining whether to conduct a competitive procurement in lieu of sole source contract described in this notice, and such determination shall be made at the sole discretion of the Government. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the requirement. If no responses are received, the government will proceed with the Sole Source acquisition. Your response should include a STATEMENT OF CAPABLILITY, GSA SCHEDULE INFORMATION, UNIQUE ENTITY I.D.#, BUSINESS SIZE, AND SOCIO-ECONOMIC STATUS. The Government will not pay for information submitted. All quotations/responses should be emailed to Dennis Salmonsen at dennis.salmonsen@va.gov by 5:00 P.M. PST. Thursday May 18, 2022. No telephone requests will be accepted.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/9b8976049c7440b1b2fdfe8375b4b6c2/view)
 
Place of Performance
Address: Department of Veterans Affairs Palo Alto Health Care System 3801 Miranda Ave., Palo Alto 94304, USA
Zip Code: 94304
Country: USA
 
Record
SN06323012-F 20220512/220510230057 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.