SOURCES SOUGHT
65 -- Hemodialysis Machine
- Notice Date
- 5/12/2022 8:32:02 AM
- Notice Type
- Sources Sought
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- W40M USA HLTH CONTRACTING ACT JBSA FT SAM HOUSTON TX 78234-0000 USA
- ZIP Code
- 78234-0000
- Solicitation Number
- PANHCA-22-P-0000-003018
- Response Due
- 5/19/2022 11:00:00 AM
- Point of Contact
- Kimberly Macias, Emerita Torres
- E-Mail Address
-
kimberly.r.macias.civ@mail.mil, emerita.torres.civ@mail.mil
(kimberly.r.macias.civ@mail.mil, emerita.torres.civ@mail.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- This is a Sources Sought Notice announcement; market survey for information only, to be used for preliminary planning purposes. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. Any requests for a solicitation in response to this notice will not be honored. The Region Health Contract Office-C, Fort Bliss, TX, has an upcoming requirement to solicit for and award a contract to provide a Dialog Plus Evolution Machine - Brand Name or Equal for William Beaumont Army Medical Center, Fort Bliss, TX, 79918. Basic requirement details are listed below. This request is anticipated to result in a Firm Fixed-Priced contract. The type of solicitation to issue will be based upon the responses to this synopsis. Contact with Government Personnel, other than the Contract Specialist identified at the bottom of this notice, by any potential offeror, or their employees�, regarding this requirement is strictly prohibited. � The purpose of this synopsis is to gain knowledge of interest, capabilities and qualifications of various members of the Small Business Community to include Section 8(a), Historically Underutilized Business Zones (HUB-Zone), Women-Owned Small Business, and Service-Disabled Veteran-Owned Small Business (SDVOSB), as well as the interest, capabilities and qualifications of various members of the Large Business community, to compete and perform a Firm Fixed Price Contract for these supplies. The type of solicitation to issue will depend upon the responses to this sources sought synopsis. The Government must ensure there is adequate competition among the potential pool of responsive contractors. The North American Classification System (NAICS) code for this requirement is 334510� �Electromedical and Electrotherapeutic Apparatus Manufacturing� The Small Business Size Standard in millions of dollars is 1,250 number of employees.�� ������������������������������������������������������������������������������������� �������������������������������������� Responses to this Sources Sought Notice should demonstrate the firm�s ability, capability, and responsibility to provide and deliver the products listed below. In response to this notice, interested parties shall submit a written Statement of Capability limited up to 5 pages and shall include the following information: �Offeror�s name, address, point of contact, phone number, and e-mail address. �Offeror�s interest in providing a proposal/quote on the solicitation when it is issued. �Offeror�s capability to provide the products being requested. �For reference the proposed offeror must be able to provide the following items: Dialog Plus Evolution Machine - Brand Name or Equal Offeror�s capability to perform a contract of this magnitude and complexity (include offeror�s capability to provide Dialog Plus Evolution Machine - Brand Name or Equal for William Beaumont Army Medical Center, Fort Bliss, TX, 79918, �in support of the Optometry Clinic. �Documentation of appropriate products must be presented in sufficient detail for the Government to determine that your company possesses the necessary means to compete for this acquisition. Offeror�s type of small business and Business Size (Whether 8(a), HUB Zone, Women-Owned Small Business, Service Disabled Veteran Owned Small Business, etc.), or Large Business Status, should be documented in the Statement of Capability. Interested parties are responsible for marking information that is proprietary in nature. No reimbursement will be made for any costs associated with providing information in response to this notice or any follow up information requests. The Government is not obligated to, nor will it, pay for or reimburse any costs associated with responding to this sources sought notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.� No subcontracting opportunity is anticipated. A determination by the Government to not compete this proposed contract action based on the responses to this notice is solely within the discretion of the Government. Interested Offeror shall respond to this Sources Sought Notice no later than 19 May 2022 at 1:00 P.M Central Standard Time. All interested businesses must be registered in the System for Award Management (SAM) at www.sam.gov to be eligible for award of Government contracts. Email your response to Kimberly Macias at email: kimberly.r.macias.civ@mail.mil or Emerita Torres at emerita.torres.civ@mail.mil. Telephonic inquiries will NOT be honored. EMAIL IS THE PREFERRED METHOD. HEMODIALYSIS EQUIPMENT � Dialog Plus Evolution Machine or Equal SALIENT CHARACTERISTICS Dialog Plus Evolution Machine or Equal (Quantity 3 ea.) Required Characteristics Must be FDA approved Must be compatible/interoperable with current system: Dialog+ Model# 7100200L Must have high resolution with true color and fundus photography Must be able to program to automatically turn on/off, run disinfection and start preparation Must have an Event Timer to set reminder alarm for individualized events Must have Patient Card Reader to store patient settings and Adimea data for a quick, accurate setup Must have 23 pre-programmed UF profile capabilities Must have rotating touch screen monitor with LCD Display, 15� color, LED Backlight, Wireless Interface, USB Port and HDF Online Must have Standby Mode Weight between 80-85 lbs Must have Blood Circuit ranges: Arterial pressure (-400 to +400 mm Hg); Venous pressure (+20 to +390 mm Hg); Blood Pump range (0-600 mL/min) and Heparin pump range (0.1-10 profiling, mL/hr) Must have Dialysate pressure displayed parameters Manufacturer Disclosure Statement for Medical Device Security (MDS2) Must provide 2 Operator/User Manuals Training: Training for nursing staff not to exceed 10 personnel Training for two clinical engineers Upon completion of training, vendor must provide a sign in roster of clinical staff that attended training Installation: Vendor install to include uncrating, inside delivery to clinic, set up and certifying equipment, removal/disposal of all packaging material Vendor must provide all tools/equipment needed for offload, inside delivery/installation Delivery Requirements: Seller must notify Property Warehouse and/or Contracting Officer Representative 3-business days before delivery of equipment Contract number must be clearly displayed on all shipping labels and is displayed on outside of package Seller must provide delivery/tracking information. Signature required for delivery NOTE: NO Grayed or refurbished items NO partial orders allowed. Vendor is responsible for shipping to delivery address listed in contract Loading dock is available at location
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/b35fccd9ac864fb1af8d065bfaa8baef/view)
- Place of Performance
- Address: Fort Bliss, TX 79918, USA
- Zip Code: 79918
- Country: USA
- Zip Code: 79918
- Record
- SN06326197-F 20220514/220512230110 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |