Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 25, 2022 SAM #7481
SPECIAL NOTICE

Z -- Building 652/654 and 785 Building Renovations

Notice Date
5/23/2022 9:53:24 AM
 
Notice Type
Special Notice
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
W2SD ENDIST NEW YORK NEW YORK NY 10278-0004 USA
 
ZIP Code
10278-0004
 
Solicitation Number
W912DS22S0038
 
Response Due
6/7/2022 11:00:00 AM
 
Point of Contact
Michael McCue
 
E-Mail Address
michael.l.mccue@usace.army.mil
(michael.l.mccue@usace.army.mil)
 
Description
1. � � � � The New York District plans to solicit and award an Invitation for bid construction� project for subject project in FY22. 2. � � � � This notification serves three (3) purposes: A. �To notify potential bidders of the Government�s intent to solicit a brand name(s) only� component for this project. B. � �To identify potential sources that can provide an equivalent to the brand name only item(s). C. �Notification of the Army�s intent to solicit brand name components as described below. 3. � � � � The �items �described �below, �under �summary �of �requirements, �are �embedded �in �the� construction project. � The contract will be issued as a competitive Invitation for Bid� solicitation. Only the components described below will be sole source, if no other sources are� identified that can provide an equivalent system. �In the event no equivalent sources are found,� the brand name only justification will be issued pursuant to FAR Part 6.302-1, Only One Responsible� Source. �A subsequent market survey will not be published in support of a Justification and� Approval for sole sourcing. Supplies of the brand name component will be provided directly to the� Contractor(s) and not to the Government. 4. � � � � Summary of Requirements: A. �Shark 200 meter Due to post wide compatibility issues and based on the capabilities described below of the Shark� 200 meter, all new construction and renovation projects at the USMA, West Point are now featuring� the latest version of the Shark 200 meter. All incoming electrical services shall be metered at the main distribution switchboard, on the line� side of the service disconnect switch. Meters shall be revenue grade with advanced I/O and power�quality. Meter shall be sole sourced to Shark 200 as manufactured by Electo Industries/GaugeTech.�No substitutions will be permitted, as it�s an approved meter that can be etwork. Any other meter cannot be connected to the West Point�s Metering Network. Shark 200 meter shall be equipped with V2 of higher V-Switch technology. Meter shall be provided with INP100S and PO1S I/O boards for communication. Pulse output cable from each utility meters to the Shark meter in a 3/4"" conduit and terminate it� into the PO1S I/O board (min of 4 connections required). Run a Cat6E cable from the shark meter's� INP100S I/O board to the NEC IT room to connect meter into West Point's Metering Network. B. Complete Monaco Fire Alarm System Due to post wide compatibility issues and based on the capabilities described below of a Monaco� Fire Alarm system, all new construction and renovation projects at the USMA, West Point are now� featuring the latest version of the Monaco Fire Alarm Control Panel. The MAAP Plus Analog� Addressable Integrated Radio Transceiver and Fire Alarm Control Panel is capable of point reporting� up to 1584 addressable device points via proprietary UHF radio signal to the Monaco D-21 Enhanced� Central Radio Control Alarm receiving system at West Point Fire Department Dispatch. New Fire Alarm� installations include Mass Notification Systems (MNS) in accordance with DoD Unified Facilities� Criteria (UFC) 4-021-01. The existing RF infrastructure provided by Monaco supports the UFC� requirements for primary MNS communications. The Monaco Fire Alarm and integrated MNS system has� the capability to remotely activate the in- building MNS messaging system and provide live-voice� announcements directly from the D-21 Central Station at West Point Fire Dispatch. Each Fire Alarm System (FAS) and Mass Notification System (MNS) shall be a complete, supervised,� non-coded, analog-addressable system, installed in class A configuration per NFPA 72. The FAS/MNS� shall provide point reporting to the Fire Alarm Control Panel (FACP). The FACP shall in turn� provide point reporting to the Monaco D-21 Central Receiving Station at USMA West Point Fire� Department Dispatch. Point reporting, also known as point-to- point reporting, is the capability to� relay the status of each addressable device and certain system components such as Signaling Line� Circuits (SLC) to the D-21 Central Receiving Station in real time. The FAS/MNS shall be tested and� perform as a critical life-safety system. The FAS/MNS shall be compatible with and shall� communicate seamlessly with the D-21 Central Receiving Station, without impairing operational� function or reliability of any existing FAS or MNS. Use of interfacing relays between the FACP and� communications transceiver to provide point or zonal alarm trouble status shall not be permitted. All devices must comply with the Aug 1997 Federal Wireless communication commissions office of� engineering and technology Bulletin 65, Evaluating Compliance with the FCC Guideline�s for Human� Exposure to RF Electromagnetic Fields. C. Best Hardware Lock Cylinders & Cores (Non-Electronic) Due to compatibility and consistency issues with keying at the USMA, Best lock is the are. �This� applies to locks that are not electronic. Hardware locksets shall accommodate Best lock cylinders and cores. D. Voice DAS C Squared is West Point�s contracted maintenance contractor for the existing Voice cell system. They currently do all the design, installation, configuration and provide maintenance support at West Point. Anther supplier will have no familiarity with the West Point environment which would result in issues connecting to the existing network. E. CAC Hirsch Card Access Systems by Embrace Technologies: Redtop Company is the only registered and certified contractor to perform all the card access work at USMA. Redtop Company uses the Hirsch / Embrace Altronix Card Access Systems that are also certified DoD security systems and used by USMA. 5. Any vendor that wishes to provide an alternate source to the brand names above that is compatible with the above must provide a response with data supporting the claim within 15 business days of this announcement to New York District Corps of Engineering, Contracting Division. 6. This is a market survey and notification of intent only. This is not a request to respond to a solicitation. This requirement will be solicited at a future date.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/6c631a462acd4aaa9dda86be8582ca7b/view)
 
Place of Performance
Address: West Point, NY 10996, USA
Zip Code: 10996
Country: USA
 
Record
SN06334751-F 20220525/220523230056 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.