SOURCES SOUGHT

65 -- Ellex Absolu S Ultrasound with A-Std Probe or equal

Notice Date
7/22/2022 11:54:43 AM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
PCAC HEALTH INFORMATION (36C776) INDEPENDENCE OH 44131 USA
 
ZIP Code
44131
 
Solicitation Number
36C77622Q0423
 
Response Due
7/29/2022 3:00:00 PM
 
Archive Date
08/13/2022
 
Point of Contact
Shaunte Chandler, Contract Specialist, Phone: VHACLEPCACSTL1@va.gov
 
E-Mail Address
shaunte.chandler@va.gov
(shaunte.chandler@va.gov)
 
Awardee
null
 
Description
This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products and/or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to otherwise pay for the information submitted in response to this Sources Sought Notice. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this Sources Sought Notice in accordance with (IAW) FAR Part 15.201(e). The purpose of this Sources Sought Notice announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the products and/or services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) Company Name; (b) Address; (c) Point of Contact; (d) Phone, Fax, and Email; (e) UEI Number; (f) Cage Code; (g) Tax ID Number; (h) Type of Small Business, e.g., Services Disabled Veteran Owned Small Business, Veteran Owned Small business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, or Small Business HUBZone business, etc.; (i) State if your business has an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed below and provide the contract number; and (j) Must provide a response containing a written statement, confirming you can comply with the government needs. All responders to this Sources Sought Notice understand, by submitting this written statement, they are certifying they can meet ALL criteria. Requirement: Ellex Absolu S Ultrasound with A-Std Probe or equal. Please see Statement of Requirement for more specifics and details. The North American Industry Classification System Code (NAICS Code) is 339112 (Surgical and Medical Instrument Manufacturing), size standard 1,000 Employees. Important Information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service-Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open may be used. Responses to this notice shall be submitted via email to Shaunté Chandler at VHACLEPCACSTL1@va.gov and shaunte.chandler@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, July 29, 2022, at 5:00 PM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Statement of Requirement Specifications/Characteristics: Minimum technical specs must be provided to meet the requirements of the GCVHCS/JACC: Absolu S Ultrasound with A-STD Probe or equal (2-year warranty) 15 MHz B Probe 20 MHz Annular B Probe kit 50 MHz Linear High-Resolution Probe (Only compatible with Absolu systems) Wireless 9 Function Footswitch for Absolu/Absolu S Height adjustable Absolu Cart with keyboard tray Technical Specifications: BIOMETRY Adjustable gain: 20 to 110 dBAdjustable Time Gain Control (TGC): 0 to 30 dB11 MHz Probe Transducer frequency: 11 MHzTip diameter: 7 mm (0.28 )Electronic resolution: 0.04 mm (0.0016 )Depth of exploration: 40/80 mm (1.57 /2.36 ) on 2048 points Aiming beam: LED or laser beam ProBeamTMContact and immersion techniques compatibleAxial length measurements Ultrasound propagation velocity adjustable per segment (anterior chamber, lens, vitreous) and IOL and vitreous material Built-in pattern recognition: Phakic, Dense/Long, Aphakic, PMMA, Acrylic and silicon for pseudo-phakic eyesAcquisition modes: Automatic, Auto+save, manual Automatic detection of scleral spikeAutomatic calculation of standard deviation and average total length (series of 10 measurements) IOL calculation SRK-T, SRK 2, HOLLADAY, BINKHORST-II, HOFFER-Q, HAIGIS Post-op refractive calculation: - Pre-op and Post-op refraction, Pre-op and Post-op keratometry - 6 different methods for keratometric correction and implant calculation: History derived, refraction derived, contact lens method, Rosa regression, Shammas regression, Double K/SRK-T (Dr. Aramberri s formula) 9 values bracketed for desired ametropia for each IOL (IOL increment steps: 0.25D or 0.50D) Simultaneous display of 4 different IOL calculations DATA MANAGEMENT Built-in physician and patient databaseExportation of still images and video sequences Customizable digital and printed reportsDICOM* and/or EMR compatible Compatible with PC, USB video and DICOM printersStorage capacity: no restriction of number of exams per patient *in options GENERAL INFORMATION Connection 5 USB ports (1 on the base 4 on the bottom of the screen)HDMI and Ethernet outletsWindows 10 embedded exploitation systemHDD 1TB - SSD128 Gb RAM 16 GbNo restriction of storage in patient fileElectrical requirements Power supply: 80-264 VacFrequency: 47/63 Hz Power: 60 VA maxFeaturesOverall dimensions: Height 445 mm (17.51 ) - Depth 285 mm (11.22 ) - Width 545 mm (21.46 ) (W/O probe holders) and 840 mm (33.07 ) with all probesScreen dimensions: 21 inch HD (1920*1080p)Weight: 10.6 kg (23.37 lbs) (w/o probes) B SCAN MODES Grey levels: 256Adjustable gain: 20 to 110 dBAdjustable Time Gain Control (TGC): 0 to 30 dBAdjustable dynamic range: adjustment from 25 to 90 dB (for 15 and 50 MHz - 80 dB for 20 MHz 5A) Image post-processing tools: filters (algorithm and colors), calipers, areas, angles, markers, commentsGlaucoma quantifying semi-automated tools: AOD 500 & 750, TIA, IT 750 & 2000, ARA 500 & 750, TISA 500 & 750, LVCineloop in B mode: up to 400 images POSTERIOR POLE EXAMINATION Magnetic 15 MHz probe Transducer frequency: 15 MHzAngle of exploration: 50°Depth of exploration: 60 mm (2.36 )Focus: 24 mm (0.94 )Depth of field: 12 mm (0.47 )Axial resolution: 115 m Lateral resolution: 400 mFrame rate acquisition: up to 16 HzAccelerometer for probe localizationMagnetic Annular 5 rings 20 MHz probe Transducer frequency: 20 MHz Annular 5 ringsAngle of exploration: 50°Depth of exploration: 60 mm (2.36 )Focus: 22 mm (0.87 )Depth of field: 20 mm (0.79 )Axial resolution: 80 mLateral resolution: 200 mFrame rate acquisition: up to 16 HzAccelerometer for probe localization UBM & ANTERIOR SEGMENT EXAMINATION Magnetic 50 MHz UBM probe with linear scanningTransducer frequency: 50 MHzLinear transducer movement: 16 mm (0.63 )Focus: 10 mm (0.39 )Axial resolution: 35 mLateral resolution: 60 m Accelerometer for probe localization STANDARDIZED A MODEDigitally programmed S-shaped amplifier characteristics and comprehensive design criteria for standardized echography and tissue differentiation according to Karl C. Ossoinig MD. Automatic tissue sensitivity determination with specific gain value recorded.Diagnosis functions featuring: Lesion Q1, Retina A1, Retina Q2, muscular profile with Optic nerve measurementsProbe Frequency: 8 MHz parallel beamCineloop in A mode: up to 400 imagesDepth: orbit 80 s, eye 40 s, zoom 20 sDistance measurement between 2 gates with adjustable velocity Specifications are subject to change without notice. ©2019. Quantel Medical, ABSolu is a registered trademark of Quantel Medical. Delivery: GCVHCS 400 Veterans Ave, Bldg. 26 Warehouse Biloxi, MS 39531
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/27762006ee7d4d7ebd25d811a99df434/view)
 
Place of Performance
Address: 400 Veterans Ave. Bldg. 26 Warehouse, Biloxi, MS 39531, USA
Zip Code: 39531
Country: USA
 
Record
SN06399667-F 20220724/220722230116 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.