SOURCES SOUGHT

65 -- 5 Wound Vacuums for Wound Therapy -Jackson MS VA Medical Center

Notice Date
8/9/2022 5:30:42 PM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
256-NETWORK CONTRACT OFFICE 16 (36C256) RIDGELAND MS 39157 USA
 
ZIP Code
39157
 
Solicitation Number
36C25622Q1129
 
Response Due
8/16/2022 9:00:00 AM
 
Archive Date
09/15/2022
 
Point of Contact
LaTonya Mack, Contract Specialist, Phone: 601-206-6964
 
E-Mail Address
latonya.mack@va.gov
(latonya.mack@va.gov)
 
Awardee
null
 
Description
Department of Veterans Affairs Network Contracting Office (NCO) 16 Request For Information (RFI) DISCLAIMER: THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS SYNOPSIS IS NOT A REQUEST FOR QUOTE, PROPOSAL, OR BID. This notice is not a solicitation as defined by FAR 2.101, therefore it shall not be construed as a commitment by the Government to enter into a contract, nor does it restrict the Government to an acquisition approach. All information contained in this Request for Information (RFI) is preliminary as well as subject to amendment and is in no way binding on the Government. Information submitted in response to this notice is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The Government is requesting that restrictive or proprietary markings not be used in response to this notice. If a solicitation is released, it will be synopsized in the Federal Contract Opportunities website or GSA. It is the responsibility of the interested parties to monitor these sites for additional information pertaining to this RFI 1. Title: 5 Wound Vacuums for Wound Therapy -Jackson MS VA Medical Center 2. Purpose: The purpose of this RFI is to identify potential sources which will aid in defining the procurement strategy (e.g., set-aside, sole source, unrestricted) for a solicitation the VA intends on issuing shortly for the following: Model / Part Number Item /Description of Supplies/Equipment Qty CAPULTDEV01/US.S V.A.C.ULTA THERAPY UNIT with V.A.C. Veraflow Therapy physical specs: 22cm x 26cm x 19cm 5 VACEXTWAR/1 YR. S Extended Warranty - 1 year 5 The anticipated Small Business Administration (SBA) size standard for the North American Industry Classification System (NAICS) code __339112__ is __1,000 employees_. STATEMENT OF WORK (SOW) 2. Contract Title: 5 Wound Vacuums for Wound Therapy 3. Background: The nursing services department is 5 Therapy Units as a technology addition for Veteran wound treatment at the GVSM. The Therapy unit must be an integrated wound management system that provides negative pressure wound therapy with an instillation option. Negative pressure wound therapy in the absence of instillation is intended to create an environment that promotes wound healing by secondary or tertiary (delayed primary) intention by preparing the wound bed for closure, reducing edema, promoting granulation tissue formation and perfusion, and by removing exudate and infectious material. The instillation option is indicated for patients who would benefit from vacuum-assisted drainage and controlled delivery of topical wound treatment solutions and suspensions over the wound bed. 4. Scope. The Nursing Service department currently utilizes similar equipment under a lease agreement for wound treatment. This procurement will serve to take the place of the rental agreement. 5. Specifications/Characteristics: Minimum Abilities of the equipment. Large Interface Screen: Intuitive, easy to use menu for simplified therapy programming. Volumetric Delivery: Therapy Unit provides volumetric fluid delivery utilizing a pump for reliable fluid delivery. Dynamic Pressure Control Therapy: It maintains a low level of negative pressure at the wound site between cycles. It helps prevent leaks and fluid accumulation that can occur when there is no negative pressure at the wound site. Dressing Soak: Tool allows the user to soak the dressing in the wound with instillation solution in preparation for a dressing change to facilitate dressing removal, potentially improving patient comfort. Test Cycle: This tool is used to perform an abbreviated Therapy instillation cycle. Each phase of the cycle will be tested to ensure system is set up and functioning as intended. Fill Assist: Fill Assist allows the user to monitor initial wound fill by manually starting and stopping instillation to determine correct instill volume after dressing is applied. Once determined, this volume will be the set point for each subsequent instill phase of therapy. Cassette: Disposable component connects the Therapy Unit to the solution bag / bottle and dressing tubing. It provides convenient solution storage and delivery. Touch Screen User Interface: The touch screen user interface allows for easy navigation through operational and help menus. A screen guard is available to help prevent unintentional changes. A settings lock is available to prevent patient access to therapy settings. Adjustable Negative Pressure Settings and Therapy Modes: Settings can be selected from a range of 25 mmHg to 200 mmHg in increments of 25 mmHg. In addition, the Therapy mode can be set for continuous negative pressure or Dynamic Pressure Control Therapy. Seal Check Leak Detector: This tool assists the user in finding negative pressure leaks in the system through the use of audible tones and on-screen visual aids during the troubleshooting process. History Reports: The Therapy System provides three possible reports: 1. Alarm History, 2. Therapy History, and 3. Patient History. These chronologically logged reports include the date and times for therapy starts / stops, therapy settings, alarm occurrences, and disposable component changes. They can be reviewed on-screen or transferred electronically from the Therapy Unit via a non-powered USB flash memory stick or SD memory card. Monitors and maintains target pressure at the wound site, helping to deliver consistent therapy. This system includes therapy unit hardware and software, wound exudate collection canister, canister detection method, multi-lumen tubing, connector and Pad. In-Line Tubing Connectors: The system incorporates an in-line dressing connector and tubing clamps to conveniently allow the wound dressing to be temporarily disconnected from the therapy unit. Canisters: The Therapy Unit is optimized for use with 500 mL or 1000 mL canisters. These are the same canisters used with Therapy Unit. Canisters are single use, latex free, sterile components. Canister Release Button: The canister release button is illuminated and will flash when the canister is full. Intensity Setting: Intensity is related to the time it takes to reach the target negative pressure therapy level after the initiation of therapy. The lower the intensity setting, the longer it will take to reach the target negative pressure. Wound Image Analysis: Digital wound images can be uploaded from a digital camera into the Therapy Unit. When the wound perimeter is traced on-screen with the provided stylus, wound image surface area and volume can be calculated and trended by the therapy unit. A chronological graphical history of the wound (with wound image area trend chart) can be viewed on-screen or this information can be transferred from the Therapy Unit electronically. This information is intended to be used by the treating clinician as a mechanism for providing a record of wound healing progress; it is not intended for use in the diagnosis and treatment of wounds. Hanger Mechanism: The therapy unit can be securely mounted to an I.V. pole, a bed footboard, or a wheelchair. Battery Operation: To facilitate patient transfer, battery operation is available with the Therapy Unit. During typical usage, the battery may provide up to six hours of operation before needing to be recharged Technical Specifications: Classification - Equipment must not be suitable for use in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide. Dimensions........................................... 217mm X 260mm X 191mm (8.55in X 10.25in X 7.5in) Weight.................................................................................................................... 3.35kg (7.4 lbs) Electrical Data (Power Supply) Voltage..................................................................................................................... 100 - 240 VAC Frequency..................................................................................................................... 50Hz - 60Hz Power..........................................................................................................................................60W Alarm Volume - Minimum of 72 dBA at 1 meter in maximum volume orientation. Environmental Conditions Transport and Storage Temperature Range - -20 °C to 60 °C (-4°F to 140°F) Operational Temperature Range....................................................... 10 °C to 30 °C (50°F to 86°F) Relative Humidity Range .................................................................. 10% to 85% non-condensing Barometric Pressure Range..............................................................................700 hPa to 1060 hPa Instill Pump Volumetric Accuracy 6 - 10 ml ± 2 ml 12 - 50 ml ± 20% 55 - 500 ml ± 15% Accuracy Testing performed under the following conditions Room Temperature ...............................................................................22.5°C ± 2°C Solution.......................................................................................................... 1000 mL bag of 0.9% saline fluid located on solution container hanger arm Downstream pressure .......................................................................... 0 psi with discharge height at pump rotor centerline Testing Duration............................................................................................... usage up to 72 hour General specifications Must be applicable for following wounds: chronic acute traumatic subacute and dehisced wounds partial-thickness burns ulcers (such as diabetic, pressure and venous insufficiency) flaps and grafts 6. Delivery. G.V. Sonny Montgomery VAMC Warehouse 1500 E Woodrow Wilson Drive Jackson, MS 39216 3. Responses Requested: The following questions must be answered in response to this RFI. Answers that are not provided shall be considered non-responsive to the RFI: a. Where are the requested items/equipment manufactured? Vendor must attach documentation of this information to be viewed by the government to be considered as part of the Market Research and responsiveness to this Sources Sought notice b. Are the requested items/equipment manufactured by a Small or Large business? Is the potential vendor in compliance with the Non-Manufacturer Rule (NMR)? Vendor must attach documentation of this to be viewed by the government to be considered as part of the Market Research and responsiveness to this Sources Sought notice c. Is the Vendor an authorized distributor with access to Original Equipment Manufacturer (OEM) parts which may be required in performance of this requirement? The VA does not accept grey market items and therefore the Vendor must attach evidence of this access (Authorized Distributor letter) to be viewed by the government to be considered as part of the Market Research and responsiveness to this Sources Sought notice. d. Name of potential Contractor that possess the capability to fulfill this requirement. Contractors shall also provide the following: Point(s) of contact name: _______________________________________________ Address: ___________________________________________________ Telephone number: ___________________________________________ Email address: _______________________________________________ Company's business size: ________________________________________________ Data Universal Numbering System (DUNS) #: _______________________________ e. Is your company considered a small business concern, SB, SDVOSB, VOSB, HUBZone, or 8A concern, with the requisite __________________ NAICS code? Please provide proof of qualifications. f. Is your company available under any Government Wide Agency Contract (GWAC), General Services Administration (GSA) Schedule, Indefinite Delivery Indefinite Quantity (IDIQ), and/or Blanket Purchase Agreement (BPA)? If so, please identify the contract number for the Government to review as part of this Market Research. 4. Opportunity/Market Pricing: The Jackson VA Medical Center is seeking information from potential vendors on their ability to provide the required items/equipment. THIS IS A SOURCES SOUGHT REQUEST FOR INFORMATION (RFI) ONLY. Small Business Concerns are encouraged to provide responses to this RFI in order to assist the Jackson VAMC in determining potential levels of competition and general market pricing available in the industry. Therefore, vendors are requested to submit estimated market research pricing along with their responses to the above. The estimated pricing will be considered when determining the procurement strategy for the forthcoming solicitation. 5. Instructions and Response Guidelines: Questions regarding this RFI shall be submitted no later than 1:00pm (CST), Friday August 12, 2022 via email to latonya.mack@va.gov RFI responses are due by 11:00am (CST), August 16, 2022; size is limited to 8.5 x 11 inches, 12-point font, with 1-inch margins in Microsoft Word format via email to latonya.mack@va.gov. The subject line shall read: 5 Wound Vacuums for Wound Therapy. NO SOLICITATION EXISTS AT THIS TIME. There is no page limitation on subparagraphs 3(a) - 3(f). Please provide the information you deem relevant in order to respond to the specific inquiries of the RFI. Information provided will be used solely by Jackson VAMC as Market Research and will not be released outside of the Network Contracting Office (NCO) 16. 7. Contact Information: LaTonya G Mack LaTonya.Mack@va.gov Your response to this notice is greatly appreciated!
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/aaf253a8ed4d4fc1ac1cc486072903bf/view)
 
Place of Performance
Address: Department of Veteran Affairs G.V. Sonny Montgomery VAMC Deliver To: Warehouse 1500 E Woodrow Wilson, Jackson 39216
Zip Code: 39216
 
Record
SN06420282-F 20220811/220809230124 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.