Z -- Repair Test Cell Doors, Bldgs. 175 & 176, NAS Lemoore, CA

Notice Date
8/11/2022 7:59:44 PM
 
Notice Type
Award Notice
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
NAVFAC SOUTHWEST SAN DIEGO CA 92132-5000 USA
 
ZIP Code
92132-5000
 
Solicitation Number
N62473-22-R-J501
 
Archive Date
08/26/2022
 
Point of Contact
Nathalie Zielinski, Phone: 5599983892, Antonio B. Harley, Phone: 5599982086
 
E-Mail Address
nathalie.m.zielinski.civ@us.navy.mil, Antonio.b.harley1@navy.mil
(nathalie.m.zielinski.civ@us.navy.mil, Antonio.b.harley1@navy.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Award Number
N62473-20-D-1104
 
Award Date
08/11/2022
 
Awardee
MACRO-Z-TECHNOLOGY COMPANY CA 92701-3878 USA
 
Award Amount
294000.00
 
Description
At Buildings 175 and 176 the main Test Cell doors are not fully operable. Both buildings need fully functioning doors and guide vane systems repaired back to original installed condition. Contractor shall provide the following: all labor, materials, equipment, incidental engineering, transportation necessary and supervision to ensure a complete and finished product as described in general in the scope of work or shown on any attached drawings. All work shall be performed during regular working hours. Contractor is only able to work on one building at a time. Government will not guarantee contractor is able to work on both buildings at the same time. The main blast doors do not need to be removed, nor do the dents need to be fixed, UNLESS the dents are preventing operations of the door systems. � Building 175 a. Test and repair all related components related to the main Test Cell door to include but not limited to: (hydraulic systems, locks, hinges and wheels). b. Remove and replace entire guide vane mechanical system, to include but not limited to: motors, chains and sprockets. Building 176 a. Test and repair all related components related to the main Test Cell door to include but not limited to: (hydraulic system, locks, hinges and wheels). b. Remove and replace entire guide vane mechanical system, to include but not limited to: motors, chains and sprockets. c. Repair turning vanes to allow operations without any friction between stationary and movable vanes. d. Remove and replace the locking cylinders for the turning vane. Adjust limit switches as needed to allow proper locking.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/530127b7ef2242aea5e22f00e8122cc8/view)
 
Place of Performance
Address: Lemoore, CA 93246, USA
Zip Code: 93246
Country: USA
 
Record
SN06422397-F 20220813/220811230115 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.