SAMDAILY.US - ISSUE OF AUGUST 21, 2022 SAM #7569
SOURCES SOUGHT

Z -- Hydrogen Inflation Safety System, Preventative Maintenance, Grand Junction, CO

Notice Date
8/19/2022 11:30:35 AM
 
Notice Type
Sources Sought
 
NAICS
541350 — Building Inspection Services
 
Contracting Office
DEPT OF COMMERCE NOAA KANSAS CITY MO 64106 USA
 
ZIP Code
64106
 
Solicitation Number
NW-WR9476-22-00274
 
Response Due
8/25/2022 7:00:00 AM
 
Point of Contact
MARION SMITH, Phone: 8162683104
 
E-Mail Address
MARION.SMITH@NOAA.GOV
(MARION.SMITH@NOAA.GOV)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This is not a request for a quote.� This announcement is considered market research in accordance to FAR Part 10.� The purpose of this posting is to seek out qualified vendors capable of performance of annual maintenance, calibration, testing and certification warranty of the Hydrogen Inflation Safety System (HISS) at Upper Air site located in Grand Junction, CO. The vendor must have expert knowledge on how the entire gas storage and delivery system works for proper annual calibration and warranty of the equipment. Hydrogen is the main gas and Helium is used as a backup gas to fill balloons.� All responsible sources are invited to respond. Submit a brief capabilities statement that clearly demonstrates the ability to provide the services indicated below. At a minimum: Company name, address, telephone number, point of contact, email and fax information. Unique Entity Identification, CAGE code, business size and socio-economic classification.� Description or past performance specifically related to the requirement. Work: The contractor shall perform maintenance, calibration, and testing to be completed to ensure optimum operation.� Item/Activity Regulator (NWS part) Visual inspection of gauges and condition. Set for proper nozzle discharge pressure (<15 psig). Gas tubing and valves Visual inspection of valve and tubing components for damage. Check valve operation. Replace any damaged handles or valve components Confirm all valves mounted securely. Repair/replace as needed. Signage Visual Inspection � damaged or missing.� Valve labels, NFPA 704 placards, hydrogen warning signs, tubing labels, operational signs. Repair replace as needed. Leak check of all hydrogen tubing and fittings With lines pressurized (HISS in RUN with all HY valves open) spray �SNOOP� leak detection solution on each fitting. Repair any leaks noted. Mass Flow Meter calibration Remove MFM and replace with calibrated unit with updated calibration sticker. Annual calibration required. MFM functional test Confirm that gas flow shuts off after flowing ~ 100 cu. ft. of gas into a balloon.� . Fan functional test Lift power supply to fan and confirm system shuts down after ~ 10 sec. Apply simulated load to fan circuit and confirm fan shuts down after ~ 10 sec. Check E Stop function Activate E stop at 4 button switch. Confirm system shut down. Hydrogen Solenoid Valve Confirm stoppage of gas flow upon valve closure. Component Enclosures Inspect for sealing, operation and no damage. Repair replace as needed. Bleed valve Confirm functionality The government will provide the following: Access to the site. Provide the contractor with any known system damages prior to the site visit. Provide Hydrogen at least one full 6 pack of Hydrogen. Extended Warranty Services: Repair or replacement of any HISS component that exhibits failure, whether during the inspection or any other time throughout the year, shall be completed within 15 working days of notification.� The following parts shall be covered due to failure from normal operations: 1. Mass Flow Meter, 2. HISS controller, switches, pushbuttons and all interior components, 3. Solenoid valve, 4. Fans, 5. All valves associated with the Hydrogen and Helium gas systems, 6. All stainless-steel tubing and convoluted flexible lines, 7. Gauges, 8. Component enclosures, 9. Gas cages. Conclusion: The contractor shall provide an inspection report documenting the results of the annual service.� The report shall be given to the local office and to the GCP. The sources sought request is for information only. Please respond via email to marion.smith@noaa.gov.� Responses are not considered offers and cannot be accepted by the Government as a binding agreement.� The Government will not reimburse respondents for any cost associated with the submission of a capability statement in connection with this market survey.�� Any information provided is voluntary.�
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/7fed45adb0f846128a18312d2836d849/view)
 
Place of Performance
Address: Grand Junction, CO 81506, USA
Zip Code: 81506
Country: USA
 
Record
SN06434847-F 20220821/220819230117 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.