SOURCES SOUGHT
41 -- Portable Air Units
- Notice Date
- 9/14/2022 11:06:29 AM
- Notice Type
- Sources Sought
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- 244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
- ZIP Code
- 15215
- Solicitation Number
- 36C24422Q1287
- Response Due
- 9/19/2022 9:00:00 AM
- Archive Date
- 11/18/2022
- Point of Contact
- Ron Kline, Contracting Officer, Phone: 412-822-3755
- E-Mail Address
-
ronald.kline@va.gov
(ronald.kline@va.gov)
- Awardee
- null
- Description
- Purpose and Objectives: The intent of this Sources Sought Notice is to identify potential businesses, especially any Small Businesses, Service Disabled Veteran Owned Small Businesses (SDVOSB) or Veteran Owned Small Businesses (VOSB) capable of providing Brand Name or equal Portable Air Conditioning Units as per below salient features for the VA Medical Center, Wilmington, DE. Statement of Need 1. Scope: The successful Contractor shall deliver to the Wilmington VAMC the following items per salient features; A. Air Conditioning Units, 5 each Programmable Control Panel Cooling Capacity Rating Conditions: 95°F @ 60% RH 13,200 Btu/h Electrical Characteristics: Voltage Requirement (60 Hz) 1 Phase, 115V Total Power Consumption 1.3kW Current Consumption 11.5 amps Recommended Fuse Size 15 amps NEMA Plug Configuration 5-15P Min.-Max Voltage 104-127V Fans - Motor Output 0.23 kW Evaporator: Fan Type Centrifugal Max. Air Flow - High/Mid/Low 440/410/385 CFM Max. External Static Pressure 0.31 IWG Condenser: Fan Type Centrifugal Max. Air Flow - High/Mid/Low 830/770/720 CFM Max. External Static Pressure 0.19 IWG Compressor: Type Hermetic Rotary Output 0.75kW Refrigerant Type R-410A Dimensions: 22w x 29d x 48h in. Net Weight/Shipping Weight: 165/205 lbs. Power Cord: 14-gauge AWG (3-core) Length 10 ft Condensate Tank Capacity: 5 gal Operating Conditions: Min. - Max. @ 50% - RH 70° - 113°F Maximum Duct Length: Cold Duct Hose - 30 ft Hot Duct Hose - 60 ft Maximum Sound Level: With Condenser Duct - High/Mid/Low - 57/56/55 dB(A) Without Condenser Duct - High/Mid/Low 60/59/58 dB(A) B. Warm Air Flex Ducts, LAY45771-0060, 5 each C. Ceiling Tile, LA146373-8280, 5 each D. Flange, FLG01158, 5 each NAICS Code 333415 Product Service Code: 4140 Responses to this Sources Sought Notice should demonstrate the firm's ability, capability and responsibility to provide the principal components of supplies listed above. Responses should include the following information: Business name, address, Point of Contact, Service-Disabled Veteran Owned Small Business info and if they are a manufacturer of the items. All information is to be submitted via e-mail at ronald.kline@va.gov. Information provided will not be returned. All responses shall be in the English Language. Responses are due by 12:00 pm (EST) on Monday, September 19, 2022. No submissions will be accepted after this date and time. Questions can be submitted electronically to ronald.kline@va.gov. This is a Sources Sought Notice and submissions will be used for informational and planning purposes only. This notice does not constitute a formal Request for Quote (RFQ), nor is the government obligated to issue an RFQ. In addition, the Government does not intend to pay for any information provided under this notice. The Government is not obligated to notify respondents of the results of this survey either.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/03014d53ae6b4c6e8eb638f92411343c/view)
- Place of Performance
- Address: VA Medical Center Wilmington 1601 Kirkland Hwy., Wilmington, DE 19805, USA
- Zip Code: 19805
- Country: USA
- Zip Code: 19805
- Record
- SN06465806-F 20220916/220914230139 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |