Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 22, 2022 SAM #7601
SOLICITATION NOTICE

61 -- 117 CES Transformers

Notice Date
9/20/2022 1:44:20 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
W7MT USPFO ACTIVITY ALANG 117 BIRMINGHAM AL 35217-3595 USA
 
ZIP Code
35217-3595
 
Solicitation Number
F6E3CE2249AW01
 
Response Due
9/27/2022 8:00:00 AM
 
Archive Date
10/12/2022
 
Point of Contact
Jeffrey A. Farmer, Phone: 2057142347, Wade R. Edwards, Phone: 2057142275, Fax: 2057142472
 
E-Mail Address
jeffrey.farmer.2@us.af.mil, wade.edwards@us.af.mil
(jeffrey.farmer.2@us.af.mil, wade.edwards@us.af.mil)
 
Description
1. This is a combination synopsis/solicitation for commercial products in accordance with FAR Subpart 12.6, as supplemented with additional information included in this notice.� The Government intends to award a Firm Fixed Price contract without discussion.� This announcement constitutes the only solicitation; proposals are being requested herein and a written solicitation will not be issued 2.� This solicitation is issued as a request for quotation (RFQ). Quotes shall be valid until 1 October 2022. 3. Description of Requirement: �See full specifications in section 14.� This is an equipment only solicitation.� Installation of the transformers is NOT a part of this solicitation. 4. Delivery:� ������������������ 180 days after contract award 5. Delivery Location: ���� 117 CES, 5401 East Lake Blvd, Birmingham, Al 35217 Line Item Structure:� � CLIN 0001 - Provide 225 KVA Pad Mount Transformer - 13200V Delta Primary, 208Y/120 Wye-N Secondary - Copper, ONAN/Bell Green -Mineral Oil for Building 202. CLIN 0002 - Provide 300 KVA Pad Mount Transformer - 13200V Delta Primary, 208Y/120 Wye-N Secondary - Copper, ONAN/Bell Green -Mineral Oil for building 151 CLIN 0003 - Provide 300 KVA Pad Mount Transformer - 13200V Delta Primary, 480Y/277 Wye-N Secondary - Copper, ONAN/Bell Green -Mineral Oil for building 149 CLIN 0004 � Delivery charges (see address above) 7. This requirement solicitation is UNRESTRICTED under NAICS code 335311.� 8. Contract Clauses/Provisions: �The incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2022-03.� See attached document titled Clause/Provision Listing for a complete listing of applicable clauses and provisions.� All can be found in full text at www.acquisition.gov/. The provision at 52.212-1, Instructions to Offerors-Commercial Products and Commercial Services, applies. The provision at 52.212-2, Evaluation-Commercial Products and Commercial Services applies.� Evaluation will be based on Price and Past Performance.� FAR Part 13.106-2 procedures will be used for the evaluation for award. The provision at 52.212-3, Offeror Representations and Certifications-Commercial Products and Commercial Services, applies.� The clause at 52.212-4, Contract Terms and Conditions-Commercial Products and Commercial Services, applies. The clause at 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Products and Commercial Services, applies. 9. Quote Documents required:� In order to be considered for award, offerors shall provide (1) a quote on company letterhead including the company CAGE Code, UEI Number, and price breakout by CLIN.� Delivery charges will be listed under CLIN 0004. 10. Rejection of Quotation: Failure to demonstrate compliance with all required documentation will be cause to reject the quote without further discussion.� 11. Quote Due Date and Time: Submit quotes via email to jeffrey.farmer.2@us.af.mil, no later than 10:00 AM CST on 26 September 2022.� Late quotes cannot be accepted.�� 12. Any amendment and documents related to this procurement will be available electronically at the website: www.sam.gov. Potential Offerors will be responsible for downloading their own copy of all documents related to this procurement.�Terms remain unchanged unless the solicitation is amended in writing. 13. Attachments: Transformer Specifications 14. Specifications ����������� TRANSFORMER REQUIREMENTS 1)�������� Provide 225 KVA Pad Mount Transformer - 13200V Delta Primary, 208Y/120 Wye-N Secondary - Copper, ONAN/Bell Green -Mineral Oil for Building 202. 3PH Pad Mount Transformer Ratings Transformer Type: Pad Mounted, Compartmental-Type Meets/Exceeds DOE 2016 Efficiency Ratings Transformer Configuration: Liquid Filled Pad Mounted Complies with ANSI / IEEE C57.12.00 Transformer Feed Type: Loop Feed Complies with ANSI / IEEE C57 12.28 Phase: Three Phase Complies with ANSI / IEEE C57 12.34 Capacity: 225 KVA Complies with ANSI / IEEE C57.12.70 Vector Group: - Complies with ASTM D3487 Primary Voltage: 13200V Pentahead Entry Assembly Primary Voltage Class: 15 kV Class High-Fire Point Natural Ester Insulating Fluid Primary Phasor: Delta Non-PCB Insulating Fluid Primary BIL: 95 KV Tamper Proof Housing Secondary Voltage: 208Y/120 Hinged Front Compartment Doors, Pad Lockable Secondary Voltage Class: 1.2 kV Class Secondary Phasor: Wye-N Secondary BIL: 30 KV Note: Losses offered are typical only, not guaranteed Frequency: 60 Hz Temperature Rise: 65�C Cooling Class: ONAN; Self-Cooled Forced Air (Fans): None Tap Changer: 5-position Tap Changer Tap Qty: (2) FCAN Above Taps, (2) FCBN Below Taps Tap %: 2.5% Tap Changer Switch Location: High Voltage (HV) Front Compartment Impedance (Typical): 1.2-6.0% Typical Primary Connection Type: Dead Front Primary Termination: Well Bushings, 200A Primary Connection Qty: (6) Primary Surge Arrestors: High Voltage Elbow Surge Arrestors, Included Primary Surge Arrestor Voltage Rating: 18 kV Class Primary Surge Arrestor MCOV Rating: 15.3 kVrms Primary Over Current Protection (OCP): Bayonet Fuses, Partial-Range Current-Limiting Fuses Primary Over Current Protection Method: Fused Primary Over Current Protection Holder: Bayonet Fuse Holder w/ Drip Shield Secondary Connection Type: Live Font Secondary Connections: NEMA Spade Terminals, Externally Clamped Secondary Connection Qty: (4) Secondary Over Current Protection (OCP): N/A Grounding Provisions: (1) Grounding lug Metering Current Transformer (CT): N/A Metering Panel: N/A Auxilary Control Panel : N/A Load Break Switch: 4-Position Load Break Switch Load Break Switch Qty: (1) Load Break Switch Location: High Voltage (HV) Front Compartment Efficiency Standard(s): Meets DOE 2016 Standards, Meets ANSI/IEEE Standards K-Factor Rating (Harmonic Mitigation): K-0 (Standard) Pulse Drive Rating: N/A Insulation Fluid: Mineral Oil - Non PCB Fluid Fluid Capacity: 140 Gallons Liquid Level Indicator: Analog Dial Gauge Temperature Indicator: Analog Dial Gauge Pressure/Vacuum Indicator: Analog Dial Gauge Pressure Relief Device: Included, Automatic Action Fill Valve: Removable Bolt Fill Valve Location: Front Compartment Drain Valve: Included, w/ Sampler Drain Valve Location: Front Compartment Winding Material: Copper Ambient Temperature Rating: 40�C Sound Level: 55 dBA Elevation Rating: 3300ft (1000 meters) Above Sea Level Core Material: Iron Tank Material: Coated Steel Cabinet Material: Coated Steel Base Platform Material: Coated Steel Housing Type: Compartmental Cabinet w/ Doors, HV Compartment Left, LV Compartment Right Paint Type: Weatherproof and UV Resistant Epoxy Coating and Undercoating Special Orders - Requirements Finish Color: Munsell� 7.0 GY 3.29/1.5 Bell Green Contact us for special requirements Mounting: Pad Mounted Toll Free: 1-800-369-6671 Conduit Opening: Bottom Feed Underground Entry/Exit Load Breaker Switch: The transformer must be equipped with a load break switch. This switch has four positions: A side on + transformer on, B side on + transformer on, A and B sides + transformer on, and A and B sides + transformer off. 2)�������� Provide 300 KVA Pad Mount Transformer - 13200V Delta Primary, 208Y/120 Wye-N Secondary - Copper, ONAN/Bell Green -Mineral Oil for building 151 Transformer Ratings Transformer Type: Pad Mounted, Compartmental-Type Meets/Exceeds DOE 2016 Efficiency Ratings Transformer Configuration: Liquid Filled Pad Mounted Complies with ANSI / IEEE C57.12.00 Transformer Feed Type: Loop Feed Complies with ANSI / IEEE C57 12.28 Phase: Three Phase Complies with ANSI / IEEE C57 12.34 Capacity: 300 KVA Complies with ANSI / IEEE C57.12.70 Vector Group: - Complies with ASTM D3487 Primary Voltage: 13200V Pentahead Entry Assembly Primary Voltage Class: 15 kV Class High-Fire Point Natural Ester Insulating Fluid Primary Phasor: Delta Non-PCB Insulating Fluid Primary BIL: 95 KV Tamper Proof Housing Secondary Voltage: 480Y/277 Hinged Front Compartment Doors, Pad Lockable Secondary Voltage Class: 1.2 kV Class Secondary Phasor: Wye-N Secondary BIL: 30 KV Note: Losses offered are typical only, not guaranteed Frequency: 60 Hz Temperature Rise: 65�C Cooling Class: ONAN; Self-Cooled Forced Air (Fans): None Tap Changer: 5-position Tap Changer Tap Qty: (2) FCAN Above Taps, (2) FCBN Below Taps Tap %: 2.5% Tap Changer Switch Location: High Voltage (HV) Front Compartment Impedance (Typical): 1.2-6.0% Typical Primary Connection Type: Dead Front Primary Termination: Well Bushings, 200A Primary Connection Qty: (6) Primary Surge Arrestors: High Voltage Elbow Surge Arrestors, Included Primary Surge Arrestor Voltage Rating: 18 kV Class Primary Surge Arrestor MCOV Rating: 15.3 kVrms Primary Over Current Protection (OCP): Bayonet Fuses, Partial-Range Current-Limiting Fuses Primary Over Current Protection Method: Fused Primary Over Current Protection Holder: Bayonet Fuse Holder w/ Drip Shield Secondary Connection Type: Live Font Secondary Connections: NEMA Spade Terminals, Externally Clamped Secondary Connection Qty: (4) Secondary Over Current Protection (OCP): N/A Grounding Provisions: (1) Grounding lug Metering Current Transformer (CT): N/A Metering Panel: N/A Auxilary Control Panel : N/A Load Break Switch: 4-Position Load Break Switch Load Break Switch Qty: (1) Load Break Switch Location: High Voltage (HV) Front Compartment Efficiency Standard(s): Meets DOE 2016 Standards, Meets ANSI/IEEE Standards K-Factor Rating (Harmonic Mitigation): K-0 (Standard) Pulse Drive Rating: N/A Insulation Fluid: Mineral Oil - Non PCB Fluid Fluid Capacity: 160 Gallons Liquid Level Indicator: Analog Dial Gauge Temperature Indicator: Analog Dial Gauge Pressure/Vacuum Indicator: Analog Dial Gauge Pressure Relief Device: Included, Automatic Action Fill Valve: Removable Bolt Fill Valve Location: Front Compartment Drain Valve: Included, w/ Sampler Drain Valve Location: Front Compartment Winding Material: Copper Ambient Temperature Rating: 40�C Sound Level: 55 dBA Elevation Rating: 3300ft (1000 meters) Above Sea Level Core Material: Iron Tank Material: Coated Steel Cabinet Material: Coated Steel Base Platform Material: Coated Steel Housing Type: Compartmental Cabinet w/ Doors, HV Compartment Left, LV Compartment Right Paint Type: Weatherproof and UV Resistant Epoxy Coating and Undercoating Special Orders - Requirements Finish Color: Munsell� 7.0 GY 3.29/1.5 Bell Green Contact us for special requirements Mounting: Pad Mounted Toll Free: 1-800-369-6671 Conduit Opening: Bottom Feed Underground Entry/Exit Load Breaker Switch: The transformer must be equipped with a load break switch. This switch has four positions: A side on + transformer on, B side on + transformer on, A and B sides + transformer on, and A and B sides + transformer off. 3)�������� Provide 300 KVA Pad Mount Transformer - 13200V Delta Primary, 480Y/277 Wye-N Secondary - Copper, ONAN/Bell Green -Mineral Oil for building 149 Transformer Type: Pad Mounted, Compartmental-Type Meets/Exceeds DOE 2016 Efficiency Ratings Transformer Configuration: Liquid Filled Pad Mounted Complies with ANSI / IEEE C57.12.00 Transformer Feed Type: Loop Feed Complies with ANSI / IEEE C57 12.28 Phase: Three Phase Complies with ANSI / IEEE C57 12.34 Capacity: 300 KVA Complies with ANSI / IEEE C57.12.70 Vector Group: - Complies with ASTM D3487 Primary Voltage: 13200V Pentahead Entry Assembly Primary Voltage Class: 15 kV Class High-Fire Point Natural Ester Insulating Fluid Primary Phasor: Delta Non-PCB Insulating Fluid Primary BIL: 95 KV Tamper Proof Housing Secondary Voltage: 208Y/120 Hinged Front Compartment Doors, Pad Lockable Secondary Voltage Class: 1.2 kV Class Secondary Phasor: Wye-N Secondary BIL: 30 KV Note: Losses offered are typical only, not guaranteed Frequency: 60 Hz Temperature Rise: 65�C Cooling Class: ONAN; Self-Cooled Forced Air (Fans): None Tap Changer: 5-position Tap Changer Tap Qty: (2) FCAN Above Taps, (2) FCBN Below Taps Tap %: 2.5% Tap Changer Switch Location: High Voltage (HV) Front Compartment Impedance (Typical): 1.2-6.0% Typical Primary Connection Type: Dead Front Primary Termination: Well Bushings, 200A Primary Connection Qty: (6) Primary Surge Arrestors: High Voltage Elbow Surge Arrestors, Included Primary Surge Arrestor Voltage Rating: 18 kV Class Primary Surge Arrestor MCOV Rating: 15.3 kVrms Primary Over Current Protection (OCP): Bayonet Fuses, Partial-Range Current-Limiting Fuses Primary Over Current Protection Method: Fused Primary Over Current Protection Holder: Bayonet Fuse Holder w/ Drip Shield Secondary Connection Type: Live Font Secondary Connections: NEMA Spade Terminals, Externally Clamped Secondary Connection Qty: (4) Secondary Over Current Protection (OCP): N/A Grounding Provisions: (1) Grounding lug Metering Current Transformer (CT): N/A Metering Panel: N/A Auxilary Control Panel : N/A Load Break Switch: 4-Position Load Break Switch Load Break Switch Qty: (1) Load Break Switch Location: High Voltage (HV) Front Compartment Efficiency Standard(s): Meets DOE 2016 Standards, Meets ANSI/IEEE Standards K-Factor Rating (Harmonic Mitigation): K-0 (Standard) Pulse Drive Rating: N/A Insulation Fluid: Mineral Oil - Non PCB Fluid Fluid Capacity: 160 Gallons Liquid Level Indicator: Analog Dial Gauge Temperature Indicator: Analog Dial Gauge Pressure/Vacuum Indicator: Analog Dial Gauge Pressure Relief Device: Included, Automatic Action Fill Valve: Removable Bolt Fill Valve Location: Front Compartment Drain Valve: Included, w/ Sampler Drain Valve Location: Front Compartment Winding Material: Copper Ambient Temperature Rating: 40�C Sound Level: 55 dBA Elevation Rating: 3300ft (1000 meters) Above Sea Level Core Material: Iron Tank Material: Coated Steel Cabinet Material: Coated Steel Base Platform Material: Coated Steel Housing Type: Compartmental Cabinet w/ Doors, HV Compartment Left, LV Compartment Right Paint Type: Weatherproof and UV Resistant Epoxy Coating and Undercoating Special Orders - Requirements Finish Color: Munsell� 7.0 GY 3.29/1.5 Bell Green Contact us for special requirements Mounting: Pad Mounted Toll Free: 1-800-369-6671 Conduit Opening: Bottom Feed Underground Entry/Exit Dimensions: 72''-W x 51''-D x 50''-H Load Breaker Switch: The transformer must be equipped with a load break switch. This switch has four positions: A side on + transformer on, B side on + transformer on, A and B sides + transformer on, and A and B sides + transformer off.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/b8a2ef5f244e4c4e8f08264e1b634123/view)
 
Place of Performance
Address: Birmingham, AL 35217, USA
Zip Code: 35217
Country: USA
 
Record
SN06472588-F 20220922/220920230124 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.