Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 07, 2022 SAM #7616
SOURCES SOUGHT

66 -- 646-23-1-3470-0002 | Functional Near Infra-red Spectroscopy (fNIRS)

Notice Date
10/5/2022 11:07:52 AM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
 
ZIP Code
15215
 
Solicitation Number
36C24423Q0023
 
Response Due
10/7/2022 1:00:00 PM
 
Archive Date
10/17/2022
 
Point of Contact
Sarah Chrostowski, Contract Specialist, Phone: 814-860-2010
 
E-Mail Address
sarah.chrostowski@va.gov
(sarah.chrostowski@va.gov)
 
Awardee
null
 
Description
Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 6 DESCRIPTION THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of a solicitation. The Department of Veterans Affairs (VA), VISN 4, Network Contracting Office 4 (NCO 4), Pittsburgh is seeking information and potential qualified sources capable of meeting the following minimum requirements and salient characteristics below for Brand Name Functional Near Infa-red Spectroscopy (fNIRS). Background: VA Pittsburgh Medical Center Research Department is in need of peripheral equipment for their existing fNIRS device that was purchased in 2019. The goal of the research is to evaluate the validity of functional near-infrared spectroscopy (fNIRS) for measuring brain activity in people who have language disorders after a stroke. A fNIRS device will be used to monitor brain activity in those with and without a history of stroke and then we ll see how those measurements compare to measurements from functional MRI and how stable they are over time. 1. S-NX-120-1238 Active Source Bundle Qty: 2 8-source active source bundle for fiberless optical illumination with dual tip for NIRSport2; 240cm long Includes 1x replacement LED., 1x tree-style cable organizer 2. NX-120-2238 Photodiode Qty: 2 Bundle of 8x silicon photodiode (SiPD) active sensors for fiberless optical detection with NIRSport2; dual tip; 240cm long Includes 1x tree-style cable organizer (TREE-STD) 3. S-NX-120-2118 Detector Qty: 1 Bundle set of 8x short-channel detectors with specialized ring grommets that fit to spring-loaded and low-profile grommets. Includes interface for standard, blunt and dual tipped probes to work with NIRx, NIRScout or NIRSport 4. S-FMC-130-12-54 Cap Qty: 1 Landmark cap - 130-Positions with finished edges, Caucasian Cut, High Precision Fabric, Black, Montage: Layout according to M15_as_MARKSnNAMES montage, Size 54cm 5. S-FMC-130-12-56 Cap Qty 1 Landmark cap - 130-Positions with finished edges, Caucasian Cut, High Precision Fabric, Black, Montage: Layout according to M15_as_MARKSnNAMES montage, Size 56cm 6. S-FMC-130-12-58 Cap Qty 1 Landmark cap - 130-Positions with finished edges, Caucasian Cut, High Precision Fabric, Black, Montage: Layout according to M15_as_MARKSnNAMES montage, Size 58cm 7. S-FMC-130-12-60 Cap Qty 1 Landmark cap - 130-Positions with finished edges, Caucasian Cut, High Precision Fabric, Black, Montage: Layout according to M15_as_MARKSnNAMES montage, Size 60cm 8. S-FMC-130-12-62 Cap Qty 1 Landmark cap - 130-Positions with finished edges, Caucasian Cut, High Precision Fabric, Black, Montage: Layout according to M15_as_MARKSnNAMES montage, Size 62cm 9. ACH-H-BK Holder Qty 15 ActiCap holder (black) Top and bottom part 10. NX-410-1001 Base Qty 175 Retrofit grommet base - fits with spring-loaded grommet top 11. NX-410-1003 Grommet Qty 18 Set strength grommet tops with near zero-tension light foam pad to secure standard, dual, and blunt-tipped probes for max comfort (secures to retrofit grommet base and MRI/TMS-compatible low-profile base). Tension = 0/3 12. NX-410-1004 Grommet Qty: 18 Set strength grommet tops with low-tension spring to secure standard, dual, and blunt-tipped probes for improved comfort (secures to retrofit grommet base and MRI/TMS-compatible low-profile base). Tension = 1/3. 13. NX-410-1005 Grommet Qty 35 Set strength grommet tops with 35 medium-tension spring to secure standard, dual, and blunt-tipped probes for improved data quality (secures to retrofit grommet base and MRI/TMS-compatible low-profile base). Tension = 2/3. 14. NX-410-1006 Grommet Qty 18 Set strength grommet tops with high-tension spring to secure standard, dual, and blunt-tipped probes for maximum data quality (secures to retrofit grommet base and MRI/TMS-compatible low-profile base). Tension = 3/3. 15. ACH-LS 32R Labels Qty 5 Set of colored number labels 1-32 for actiCap holder (Red) 16. ACH-LS 32B Labels Qty 5 Set of colored number labels 1-32 for actiCap holder (Blue) 17. NX-500-1019 Stabilizers Qty 5 50x Optode Stabilizers - guarantees 3 cm maximum spacing between optode grommet positions in NIRScaps Instructions: The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above. Responses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339112 (size standard of 1000 employees). Please answer the following questions: (1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? If not, Can you provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers. Does your company exceed 500 employees Primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice; Obtained an individual or class waiver? (4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If you re a small business and you are an authorized distributor/reseller provide an authorized distributor letter for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job. (7) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. (8) If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (9) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (10) Please submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes? (11) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A (12) Please provide your DUNS number. This RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received via e-mail to sarah.chrostowski@va.gov no later than, 4:00 PM Eastern Standard Time (EST) on October 7, 2022. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist Sarah Chrostowski at sarah.chrostowski@va.gov Questions or Responses will include the Source Sought number 36C24423Q0023 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award. If a solicitation is issued, information will be posted on the beta.sam web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at sarah.chrostowski@va.gov. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/33638ecb922a4187a57318e6b81886a2/view)
 
Place of Performance
Address: Pittsburgh VA Medical Center University Drive C Pittsburgh PA 15240
Zip Code: 15240
 
Record
SN06487937-F 20221007/221005230116 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers