Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 19, 2022 SAM #7628
SOLICITATION NOTICE

H -- Triennial Electrical System Inspection and Maintenance

Notice Date
10/17/2022 12:43:22 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25023Q0050
 
Response Due
10/19/2022 1:00:00 PM
 
Archive Date
12/18/2022
 
Point of Contact
Mary Jane Crim, Contracting Officer, Phone: 937-268-6511
 
E-Mail Address
maryjane.crim@va.gov
(maryjane.crim@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
The purpose of this solicitation amendment is to provide answers to vendor questions. Please see below. On the walkthrough, it was identified that the responsibility of coordinating any service disconnect via the utility falls on the awarded contractor. Considering contractor s normally don t handle service disconnection for an the end-user, will you please provide the process for how this will need to be executed? Additionally, will you please identify any costs (if any) for service disconnection since this will be taking place off normal business hours, or on Fri/Sat? A onetime initial utility disconnect and reconnect must be coordinated with AEP and paid by the contractor. VA will approve this service.  After the initial disconnect and reconnect for preventive maintenance (PM) on the Digitrip and Disconnect Gear at the main feed, VA Engineering staff can perform shut downs without any charge to the contractor. Please confirm whether or not 480v single phase power will be provided for primary injection testing. 480V, 1Ø will be provided for primary injection testing. Transformer of 500KVA or larger shall be cleaned interiorly, inspected for sign of overheating with an infrared thermal detecting equipment and inspected for any damages to the housing, connection points, or insulation. THIS IS ONLY REQUESTING CLEANING AND INFRARED OF TRANSFORMERS NO TESTING? - SEE ATTACHMENT #2, All testing will follow ANSI/NETA MTS-2019 SECTION 7.0 THRU 8.0 Dry type transformers must be thoroughly cleaned, both interior and exterior, and inspected for overheating with infrared thermal detecting equipment. THIS IS ONLY REQUESTING CLEANING AND INFRARED OF TRANSFORMERS NO TESTING? - SEE ATTACHMENT #2, All testing will follow ANSI/NETA MTS-2019 SECTION 7.0 THRU 8.0 Electrical equipment (including, but not limited to Automatic Transfer Switches (ATS) switchgears, switchboards, distribution panels, motor control centers, and all related components) are required to be inspected, tested, maintained, and/or calibrated as follows: INSPECTED, TESTED, MAINTAINED, AND/OR CALIBRATED AS FOLLOWS BUT NO TESTING IS SPELLED OUT BELOW BESIDES GROUND FAULT DEVICES? - SEE ATTACHMENT #2, All testing will follow ANSI/NETA MTS-2019 SECTION 7.0 THRU 8.0 Calibrate and maintain adjustable protective relays. HOW MANY AND WHAT TYPE ARE THEY? - 1- MV main Eaton relay energy center MV Schweitzer relays all others 480 volt and under are square-d and Eaton/ cutter-hammer. As well this is covered under attachment #2, also please see equipment list document in original solicitation. Full testing shall be performed for all breakers rated above 200 Amps throughout the facility. FULL TESTING WOULD ASSUME PRIMARY INJECTION TESTING ON DRAW OUT BREAKERS AND SECONDARY INJECTION TESTING OF BOLT IN BREAKERS AS A VA STANDARD? MEDIUM VOLTAGE BREAKERS, SWITCHES, ATS UNITS HAVE NO DEFINED TESTING STANDARD. INFRARED AND CLEANING WOULD BE ASSUMED UNDER THIS SCOPE? DIGITAL RELAYS WOULD NOT BE PART OF THIS SCOPE. WE RECOMMEND INJECTING VOLTAGE/CURRENT AND OPERATING OUTPUTS AS A MINIMUM FOR MICROPROCESSOR BASED RELAYS - SEE ATTACHMENT #2 All testing will follow ANSI/NETA MTS-2019 SECTION 7.0 THRU 8.0 All breakers 400 amp and above will be primary injection weather bolt in or draw out type. Mary Jane Crim Contracting Officer maryjane.crim@va.gov
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/446e126349124b97849f1a09a7f2570b/view)
 
Place of Performance
Address: Chalmers P. Wyllie VA Ambulatory Center 420 North James Road, Columbus 43219
Zip Code: 43219
 
Record
SN06494759-F 20221019/221017230049 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.