SOLICITATION NOTICE
A -- Rosemount 3051SFC Compact Orifice FlowMeter - Transmitter
- Notice Date
- 10/31/2022 12:20:33 PM
- Notice Type
- Solicitation
- NAICS
- 334513
— Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
- Contracting Office
- SLAC Natl Accel Lab -DOE Contractor Menlo Park CA 94025 USA
- ZIP Code
- 94025
- Solicitation Number
- 332818
- Response Due
- 11/14/2022 4:30:00 PM
- Archive Date
- 11/29/2022
- Point of Contact
- Barbara Garcia, Phone: 6509263549
- E-Mail Address
-
barbarag@slac.stanford.edu
(barbarag@slac.stanford.edu)
- Description
- SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions. SLAC has a requirement for a U.S. domestic end item source of the following product: 3051SFC1CS060N050T33JA1������������������������������������������������������������� Qty - 1 A3Q4M5T1 Description Rosemount 3051SFC Compact Orifice Flow Meter SELECTED OPTIONS: Transmitter Feature Board Measurement Type: MultiVariable (Compensated Mass & Energy Flow); Differential/Static & Temp Primary Element Technology: Conditioning Orifice Plate Line Size: 6-in. (150 mm) Primary Element Type: 0.5 Beta Ratio (_) Temperature Measurement: Integral RTD Transmitter Connection Platform: Direct-mount Differential Pressure Range: 0 to 1000 in H2O (0 to 2.5 bar) Static Pressure Range: Gage -14.2 to 800 psig (-0.979 to 55.2 bar) Output Protocol: 4-20 mA with digital signal based on HART protocol Transmitter Housing Style: PlantWeb housing / Aluminum / 1/2-14 NPT conduit entry Transmitter Performance Class: Ultra for Flow: 0.75% flow rate accuracy, 14:1 turndown, 10-yr stability Installation Accessories: Without Remote Adapters: Without High Temperature Applications: Without Flow Calibration: Without Pressure Testing: Without Special Cleaning: Without Special Inspection: Without Transmitter Calibration Certification: Calibration data certificate for transmitter Safety Certificate: Without Material Traceability Certification: Without Code Conformance: Without Materials Conformance: Without Country Certification: Without Product Certification: Without Shipboard Approvals: Without Alternate Transmitter Material of Construction: Without Digital Display: PlantWeb LCD Display Terminal Blocks: Transient terminal block Manifold for Remote Mount Option: Without PlantWeb Control Functionality: Without PlantWeb Diagnostic Functionality: Without Special Configuration (Software): Without Special Configuration (Hardware): Without Conduit Plug: Without Conduit Electrical Connector: Without 3051TG3A2B21AS5Q4M5������������������������������������������������������������������� Qty - 2 0306RT22BA11 214CRWSMA1S3E0057SLXAXW Description Special Configuration (Software): Without Special Configuration (Hardware): Without Conduit Plug: Without Conduit Electrical Connector: Without Rosemount 3051T Pressure Transmitter SELECTED OPTIONS: Pressure Type: Gauge Pressure Range: -14.7 to 800 psig Output: 4-20mA with digital signal based on HART protocol Process Connection: 1/2-14 NPT Female Isolating Diaphragm: 316L SST (316L SST process connection) Fill Fluid: Silicone Housing Material: Polyurethane covered aluminum Conduit Entry Size: 1/2-14 NPT Warranty: 1-year PlantWeb Functionality: None Assembly Option: Assemble to Model 306 Integral Manifold Mounting Brackets: None Hazardous Location Certification: Not included Custody Transfer: Not included Shipboard Approvals: Not included Calibration Certification: Included Material Traceability Certification: Not included Quality Certification for Safety: Not included Wireless Sensor Module Material: N/A Configuration Buttons: None Display: LCD Conduit Plug: Carbon steel Transient Protection: Not included Software Configuration: Standard Alarm Levels: None Hydrostatic Pressure Test: Not included Process Area Cleaning: Not included External Ground Screw Assembly: Not included NSF Drinking Water Approval: Not included NACE Certificate: Not included Seal System Report: Only available when assembled to remote seal Conduit Electrical Connector: Not included HART Configuration: Revision 5 0306RT22BA11 ������������������������������������������������������������������������������������ Qty - 2 Rosemount 0306 Inline Manifold������������������������ SELECTED OPTIONS: Manifold Type: 2 Valve Process Connection: 1/2-14 Female NPT for inline transmitter Packing Material: PTFE Warranty: 1-year 306RT Options: None Material Recommendations for NACE: None 214CRWSMA1S3E0057SLXAXW �������������������������������������������������������� Qty - 2 Rosemount 214C RTD������������������������� SELECTED OPTIONS: Sensor Type: Wire wound PT100, -321 to 572�F (-196 to 300�C) Sensor Accuracy: Class A per IEC 60751 Number of Elements: Single, 3-Wire Dimension Units: English / US Sensor Immersion Length: 5.75 inches Sensor Mounting Style: Spring loaded adapter Extended Product Warranty: Standard warranty only Product Certifications: None Connection Head: None Conduit Entry: Only available with connection head Conduit Cable Glands: Only available with connection head Extension: None Extension Length: Extension not selected Lead Wire Extension: Wire Length: None Lead Wire Extension: Wire Type: None Lead Wire Extension: Armor Type: None Lead Wire Extension: Cable Glands: None Lead Wire Extension: Termination Style: None Calibration: None Calibration Certificate: Not included Ground Screw: None Cover Chain: None Terminal Block: None Low Temperature Housing: None Materials Options: None Transmitter Assembled To Sensor: Process ready assembly Thermowell Assembled To Sensor: Process ready assembly 114CE0030TAA2SC027AQ85X������������������������������������������� ��������������� Qty - 2 WRosemount 114C Thermowells SELECTED OPTIONS: Length Units: Inches Immersion Length: 3 inches Mounting Style: Threaded Process Connection: 1/2-14 NPT tapered threads Stem Style: Tapered stem Thermowell Material: 316/316L dual rated Head Length: 2.75 inches Instrument Connection Threads: 1/2in-14 NPT Van Stone Flange Material: Only applicable with Van Stone flanges Bore Diameter: 0.256in (6.5mm) Surface Finish Certification: Not included Canadian Registration Number: Not included NACE Approval: Not included External Pressure Test: Not included Special Cleaning: Not included Dye Penetration Test: Not included PMI Testing: Not included Material Certification: Not included X-Ray: Not included Internal Pressure Test: Internal hydrostatic pressure test & certificate of results Plug & Chain: Not included Flange Face: Only applicable with flanges Vent Hole: Not included Wrench Flats: Standard, two sides Surface Finish: Standard finish of T32 ?in CLA N6 (8 um ... or better Electropolish: Not included Wake Frequency Calculation: Not included Tip Shape: Standard flat Tip Thickness: 0.25in (6.4mm) Warranty Options: Standard manufacturer�s limited warranty Assembly Options: Process ready assembly of a sensor and thermowell 3144PD1A1NAM5XA ����������������������������������������������������������� ��������������� Qty - 2 Rosemount 3144P Temperature Transmitter SELECTED OPTIONS: Transmitter Housing Type: Aluminum - 1/2 -14 NPT Output: 4-20mA with Digital Signal Based on HARTR Protocol Measurement Configuration: Single-Sensor Input Hazardous Locations Certifications: None PlantWeb Control Functionality: None PlantWeb Advanced Diagnostic Functionality: Without Enhanced Performance: Without Mounting Bracket: None Display: LCD Display External Ground Lug: Not included Integral Transient Protector: Not included Software Configuration: None Line Voltage Filter: 60Hz NAMUR Compliant Alarm Failure: None Low Alarm: None Sensor Trim: None Five Point Calibration Data: None Calibration Certification: None Dual-Input Custom Configuration: None Custody Transfer: None Quality Certification for Safety: None Conduit Electrical Connector: None HART Revision: None Assemble to Options: Sensor (ordered separately) assembled to transmitter The award will be made based upon the Lowest Price Technically Acceptable and best lead time method. Marking of Proprietary/Confidential Information. Offerors shall properly mark and identify with a restrictive legend or information markings on pages of the proposal that contain Proprietary/confidential information. For Offeror to be eligible for a subcontract award with the University and the U.S. Department of Energy (DOE), Offeror shall be registered with the System for Award Management (SAM). Entities may register at no cost directly at the SAM website: https://www.sam.gov. The resulting purchase order shall be performed in accordance with SLAC National Accelerator Laboratory's Terms and Conditions for Fixed Price Commercial Supplies and Services dated December 2016 NOTE: The following documents are attached in this solicitation. Buy American Act Certificate Terms & Conditions for Fixed Price Commercial Supplies and Services, December 2016 Please provide quoted price, delivery, technical compliance statement and certification to the attention of Barbara Garcia. Payment Terms: Net 30 days Freight terms: FOB Destination Prepaid and Add
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/131ed0b44a3d4018adf6c4f0de7bd7e1/view)
- Place of Performance
- Address: Menlo Park, CA 94025, USA
- Zip Code: 94025
- Country: USA
- Zip Code: 94025
- Record
- SN06505864-F 20221102/221031230107 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)