SOURCES SOUGHT

65 -- IDIQ- 3 yr Binax NOW or Equal COVID Antigen Testing (VA-23-00007611) Brand Name ONLY

Notice Date
11/21/2022 9:39:14 AM
 
Notice Type
Sources Sought
 
NAICS
325413 — In-Vitro Diagnostic Substance Manufacturing
 
Contracting Office
NETWORK CONTRACT OFFICE 23 (36C263) Saint Paul MN 55101 USA
 
ZIP Code
55101
 
Solicitation Number
36C26323Q0133
 
Response Due
11/29/2022 9:00:00 AM
 
Archive Date
12/13/2022
 
Point of Contact
Wendy S Hoeschen, Wendy Hoeschen, Phone: 320-255-6307
 
E-Mail Address
Wendy.Hoeschen@va.gov
(Wendy.Hoeschen@va.gov)
 
Awardee
null
 
Description
Statement of Work- VISN 23 Binax NOW® SARS-CoV-2 Antigen Test Kit (BRAND NAME ONLY) 1. Introduction The purpose of this Statement of Work (SOW) is to detail salient characteristics for Binax NOW® SARS-CoV-2 Antigen Test Kit (BRAND NAME ONLY) and define the tasks and responsibilities of the successful offeror for the procurement of an FDA-approved or Emergency Use Authorization (EUA) Binax NOW® SARS-CoV-2 Antigen (BRAND NAME ONLY) Test Kit for thirteen (13) VA Midwest Health Care Network (VISN 23) laboratories. 3. Scope Network Contracting Office 23 (NCO23) intends to award a single agreement to the overall best-value contractor capable of meeting the requirements outlined herein for Binax NOW® SARS-CoV-2 Antigen Test Kit for clinical laboratories located at the following VA facilities: Black Hills Health Care System, Hot Springs, SD Black Hills Health Care System, Fort Meade, SD Black Hills Health Care System, Rapid City, SD Central Iowa Health Care System, Des Moines, IA VA Medical Center, Fargo, ND Royal C. Johnson VA Medical Center, Sioux Falls, SD VA Medical Center, Iowa City, IA VA Medical Center, Minneapolis, MN Twin Ports Community Based Outpatient Clinic, Superior, WI Nebraska-Western Iowa Health Care System, Omaha, NE Nebraska-Western Iowa Health Care System, Grand Island, NE Nebraska-Western Iowa Health Care System, Lincoln, NE VA Medical Center, St. Cloud, MN General Requirements: This section defines minimum requirements that must be met or exceeded by this acquisition. Narrative descriptions shall be provided of how these requirements will be met or exceeded: Technical The science of the Abbott Binax NOW® SARS-CoV-2 Antigen test shall be lateral flow immunoassay for the qualitative detection of the nucleocapsid protein antigen from SARS-CoV-2 in direct nasal swab collections. The Abbott Binax NOW® SARS-CoV-2 Antigen test kit and specimen type(s) must minimally have Emergency Use Authorization (EUA) issued by the Food and Drug Administration (FDA) pursuant to Section 564 of the Federal Food, Drug and Cosmetic Act for high complexity and moderate complexity designated laboratories. The Abbott Binax NOW® SARS-CoV-2 Antigen assay shall also be authorized for use at the Point of Care (POC), i.e., in patient care settings operating under a CLIA Certificate of Waiver, Certificate of Compliance, or Certificate of Accreditation. The analytical sensitivity of the Abbott Binax NOW® SARS-CoV-2 antigen test shall be 200 TCID50/ml or lower.     The Abbott Binax NOW® SARS-CoV-2 antigen test result must be available for result reporting within fifteen (15) minutes or less.     The Abbott Binax NOW® SARS-CoV-2 Antigen test system Reagents and collection swabs are included within the test kit.    The Abbott Binax NOW® SARS-CoV-2 collection sample shall be stable for 1 hour or longer at room temperature.   The Abbott Binax NOW® Antigen test system shall not require the use of a biosafety cabinet to process sample or perform testing.   Internal quality control material must be specific and proprietary to the Abbott Binax NOW® SARS-CoV-2 antigen test system offered and within the scope of the FDA EUA authorization. Abbott Binax NOW® SARS-CoV-2 External positive and negative quality control material must be compatible for use with the proprietary Abbott Binax NOW® reagent test system. The products in the Abbott Binax NOW® SARS-CoV-2 reagent test system must not require a storage temperature of less than 8 degrees centigrade. Room temperature storage is preferred.   Hardware and Software Equipment or instrumentation required for the performance of the testing or interpretation/reading of the test result of the proposed equal test system, shall be provided as part of the antigen test kit pricing.  If equipment or instrumentation is required for the performance of the testing or interpretation/reading of the test result of the proposed equal test system, an approved VA Enterprise Risk Assessment (ERA) for medical devices is required. The ERA number and a copy of the approved ERA report shall be provided, upon request.    If equipment or instrumentation is required for the performance of the testing or interpretation/reading of the test result of the proposed equal test system, a copy of a completed MDS2 and 6550 shall be submitted with proposal.   Network Security and Integration Requirements If equipment or instrumentation is required for the performance of the testing or interpretation/reading of the test result of the proposed equal test system, compliance of all hardware and software with VA network security, and Enterprise Risk Analysis requirements. The Contractor shall supply responses to required documents for connection of medical devices to the VA network including but not limited to the VA Form 6550, Access Control List (ACL) Communication ports and protocols, services and application inventory, network diagram, and MSD2. Contractor shall have a Memorandum of Understanding/Information Security Agreement (MOU/ISA) with the VA or the capability to obtain an MOU/ISA without creating significant implementation delays. https://vaww.portal2.va.gov/sites/infosecurity/FY15CRISPAudit/CRISPRemediationContract/WorkSite/SitePages/MOU-ISA_Version2.aspx The hardware must meet all VA minimum specifications and the software version must be approved for use on the VA network. termination. Troubleshooting Troubleshooting and assistance with the use of the Abbott Binax NOW® SARS-CoV-2 reagent test system must minimally be available through telephone hotline support. In accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following national holidays are observed and for the purpose of this contract are defined as Legal Federal official holidays . New Year s Day January 1st Martin Luther King s Birthday Third Monday in January President s Day Last Monday in January Memorial Day Last Monday in January Juneteenth June 19th Independence Day July 4th Labor Day First Monday in September Columbus Day Second Monday in October Veteran s Day November 11th Thanksgiving Day Fourth Thursday in November Christmas Day December 25th When a holiday falls on a Sunday, the following Monday will be observed as a National Holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a National Holiday by U.S. Government Agencies.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/3642b6d16abb40cab5e98ae3f7a8bb3a/view)
 
Place of Performance
Address: 4801 Veterans Drive, St Cloud, MN 56303, USA
Zip Code: 56303
Country: USA
 
Record
SN06523721-F 20221123/221122211833 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.