Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 01, 2022 SAM #7671
SOURCES SOUGHT

59 -- ATS Generator Switch - Building 19, IND

Notice Date
11/29/2022 7:51:53 AM
 
Notice Type
Sources Sought
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25023Q0147
 
Response Due
12/5/2022 9:00:00 AM
 
Archive Date
12/10/2022
 
Point of Contact
Rhonda L Fitzgerald, Rhonda L Fitzgerald, Phone: 317-988-1844
 
E-Mail Address
rhonda.fitzgerald@va.gov
(rhonda.fitzgerald@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
Page | 1 of 2 Statement of Work Remove Existing Switch, Provide, and Install A New Closed Transition Transfer Switch For Building 19 GENERAL: Contractor shall Remove Existing Switch, Provide, and Install An ASCO Closed Transition Transfer Switch for Building 19 at the Roudebush VA Medical Center, located at 1481 W 10th Street Indianapolis IN 46201 CONFORMANCE STANDARDS: All services provided under this contract must be performed in conformance with the Occupational Safety and Health Administration (OSHA), NFPA, NEC, and Original Equipment Manufacturer standards and specifications Delivery Requirements: Deliver to room AB144 at 1481 W 10th Street Indianapolis IN 46201. SERVICES REQUIRED: Remove existing ASCO 600-amp transfer switch. Provide and install new 600-amp ASCO closed transition transfer switch with a maintenance bypass. Provide factory startup and testing. Work shall be completed after normal business hours. Normal business hours are from 8am 4pm, Monday -Friday. Disposal of existing transfer switch if needed. All tools and parts necessary to complete the work. CONTRACTOR REQUIREMENTS: Contractor shall perform work in a professional manner and to the highest standards Contractor shall check in with VAMC at time of arrival and checkout as defined in service hours. Contractor to complete the VA Vendor Credentialing process and have all employees working on VA property badged with VA contractor badges through Police Services before beginning any work at the VA. All contractors shall wear VA Contractor Badges at all times during while onsite Contractor must be licensed/certified by the State of Indiana. Contractor shall be required to follow all ICRA requirements set forth by the infection control staff. Contractor to remove all trash and debris at the completion of job. The work area is to be kept clean at all times. The Contractor is to insure that all tools, equipment and material are kept and placed in an orderly fashion to have as little impact on daily operations of the hospital, staff and patients. Owner s manual will be supplied as part of the close out documentation. Contractor shall be required to complete a VAMC Indianapolis Service Ticket when the work is completed. Contractor shall perform a function test in the presence of a VA employee designated by the Electric Shop Supervisor shop. NOTE: All work is expected to encounter normal conditions. Contractor to Install equipment in accordance with the manufacturers installation instructions. If anything unusual is encountered the VA will be notified and pricing will adjust accordingly. PAYMENT FOR SERVICES: Invoices will be paid in arrears on a monthly basis upon completion of the services. Each invoice must include VA purchase order number, and invoice number and the month of the service being invoiced. The invoice should be mailed to the address identified herein. SECURITY REQUIREMENTS: The Contractor s employees shall wear visible identification and company uniforms approved by the COR at all times while on the premises of the VAMC. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police Section or from the COTR. The VAMC will not invalidate or make reimbursement for parking violations of the Contractor under any conditions. Smoking is prohibited inside any buildings at the VAMC. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court. Product 7000 Series Bypass Transfer Switches Catalog Number Service Voltage/ Hz 240V/60Hz Optional Accessories Bypass Isolation YES Product Description No. of Switched Poles 3 Neutral Configuration J7ACTBA30600F5XC,31BG 31BG 7000 Series, Automatic Closed Transition Bypass Switch Withstand Rating: See WCR table below Solid [A] No. of Cables & Lug 2, #2 AWG to 600 MCM Size Frame= J, Switch Rating= 0600, Series= 7000 Enclosure 1(C)-UL Type 1 Enclosure Service Three Phase, 4-wire
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/9674c1ad05eb49f3a67a068519519588/view)
 
Place of Performance
Address: Indianapolis Veterans Affairs 1481 W. 10TH, Indianapolis 46202
Zip Code: 46202
 
Record
SN06530239-F 20221201/221129230112 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.