SPECIAL NOTICE
53 -- NSTR-99 pertaining to N3904023R0004
- Notice Date
- 6/2/2023 9:36:14 AM
- Notice Type
- Special Notice
- NAICS
- 332722
— Bolt, Nut, Screw, Rivet, and Washer Manufacturing
- Contracting Office
- PORTSMOUTH NAVAL SHIPYARD GF PORTSMOUTH NH 03801-5000 USA
- ZIP Code
- 03801-5000
- Solicitation Number
- N3904023R0004-NSTR-99
- Response Due
- 6/20/2023 7:00:00 AM
- Archive Date
- 07/05/2023
- Point of Contact
- Tom Fuller, Phone: 2076901655, Jocelyn Cartier
- E-Mail Address
-
thomas.g.fuller17.civ@us.navy.mil, jocelyn.d.cartier.civ@us.navy.mil
(thomas.g.fuller17.civ@us.navy.mil, jocelyn.d.cartier.civ@us.navy.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- Portsmouth Naval Shipyard received the following question that it would like to publicly answer to benefit all parties interest in participating in solicitation N3904023R0004. Q: Is there any correlation between ASTM certs and MIL-STD-2132 certs? A: No, there is no reciprocity between ASTM certs and MIL-STD-2132 certs. The way we understand the process is: a vendor should submit an �Application for Nondestructive Test Examiner Examination (Appendix J)� for their method specific examiner by fax or mail to BPMI. BPMI should provide them a test date and a location where this would take place. Once the individual passes that exam, then they must devise their MIL-STD-2132 program for their company to meet the requirements of both NSTR-99 and MIL-STD-2132. MIL-STD-2132 provides the method specific requirements used to perform the inspections, create/qualify their procedures, and requirements for examination of the organization�s examiner and inspectors (enclosure 10). NSTR-99 provides specific requirements for the organization�s NDT program, such as examiner duties in respect to qualifying inspectors within the organization and maintenance of the program.� BPMI typically requires notification at least 6 weeks from the beginning of the month for which the organization hopes to test, but that does not include re-examinations, nor the amount of time it takes for that individual to create a written practice for the program, create test props if necessary, examination questions, etc. to meet the requirements of MIL-STD-2132 and NSTR-99, and then to test inspectors so they are certified to inspect the material.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/e19f7bde48ef4fba9bc34a214f9d1dd6/view)
- Place of Performance
- Address: Kittery, ME 03904, USA
- Zip Code: 03904
- Country: USA
- Zip Code: 03904
- Record
- SN06702425-F 20230604/230602230109 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |