SAMDAILY.US - ISSUE OF SEPTEMBER 16, 2023 SAM #7963
SOLICITATION NOTICE

Z -- Renovation for Welcome Center

Notice Date
9/14/2023 10:11:03 AM
 
Notice Type
Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
 
ZIP Code
23667
 
Solicitation Number
36C24623B0061
 
Response Due
10/11/2023 8:00:00 AM
 
Archive Date
12/10/2023
 
Point of Contact
Daniel L Dove, Contract Specialist
 
E-Mail Address
Daniel.Dove@va.gov
(Daniel.Dove@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
36C24623B0061 Renovation of Welcome Center Amendment 0002 - Responses to Follow-Up Vendor Questions (NOTE: Question Numbering continued from Amendment 0001) Follow up on Response for Questions 6 and 7 from Amendment 0001: Question #7 response states that 2 full time Supervisors are not allowed to serve the roles of Superintendent, SSHO, and QCM which would imply the project requires (3) full time people on site. If this is the intent, please make this clear so that all bidders include this cost as it is a significant amount to add a person to the staff full time for the duration of the project. Response: Site Superintendent can also be the Quality Control Manager, but the SSHO shall only have that one duty. If someone is a site superintendent whose qualifications meet requirements to be a SSHO, this would be acceptable for the SSHO position. Follow up on the response to Question 16 from Amendment 0001: The full hazmat report lists 512 SF of transite cement behind 32 radiators, but the table in the specifications is listing 256 SF at 32 radiators. Please confirm the amount we should figure for pricing. Response: Use 512 square feet quantity. Also, the full hazmat report lists approximately 680 LF of pipe insulation at exterior walls. Has this material already been removed or are we figuring this as well? Response: This has not been removed and is included in this project to be removed. Please confirm that the Flow Control Device shown on Detail 4 of P-002 is needed for the hot water recirculation line. Response: A flow control device should be anticipated for the hot water recirculation system. Also, for this project, assume one is currently installed balancing the system and an additional one is needed. Follow up on the response to Question 13 from Amendment 0001: Is it possible to get an approximate routing distance to the switchboard from the work area? Response: The switchboard referenced in Question 13 is located in Building #44. Building #44 is shown on the Electrical Partial Site Plan (EP-1-B-02) where the approximate routing distance can be determined by bidders. Follow up on the response to Question 14 from Amendment 0001: Thank you for confirming all interior partitions are to be addressed as key note DE1 [unless noted otherwise]. Assuming key note DE28 is to be addressed as shown on the drawings at the exterior walls, please confirm that we should figure that none of these metal studs at the exterior wall are structurally significant to the brick. Response: Metal Studs at the exterior wall are not Structurally Significant to the exterior wall system. For the response to Question 14 from Amendment 0001, we are confused as to why Brick was mentioned in the response. We want to make sure the demo of the exterior Metal Stud wall and finishes is only referring to demo of the furred-out section of the exterior wall and not the actual Metal framing that is between the exterior windows that may have exterior sheathing and brick ties tied to it. The demo drawings appear to show a wall directly in front of the exterior wall which we assume to be metal stud furring. Response: Interior furring is to be removed in its entirety. See the response to Question 29 above. Existing wall construction is a multi wythe brick, or stone wall system. Approximately sixty percent of the walls to be demolished must be assumed to be constructed of masonry floor to deck with metal stud/gypsum firring.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/a2357326e4524e29904be521209c3b86/view)
 
Place of Performance
Address: Fayetteville, NC 28301, USA
Zip Code: 28301
Country: USA
 
Record
SN06831656-F 20230916/230914230121 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.