SOLICITATION NOTICE

Z -- Replace Panic Hardware Bldg 1 Project 610A4-21-204

Notice Date
9/14/2023 9:19:42 AM
 
Notice Type
Presolicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25023B0079
 
Response Due
10/31/2023 11:00:00 AM
 
Archive Date
11/15/2023
 
Point of Contact
jeffery.hairston@va.gov, Phone: 3179881528
 
E-Mail Address
Jeffery.Hairston@va.gov
(Jeffery.Hairston@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Description
The contractor shall provide all labor, supervision, materials, and equipment to Replace Panic Hardware, doors, and frames in Building 1 at the VANIHCS-Ft Wayne campus per design drawings provided by Viridian, but not limited to the following: Replacement of old doors, closures, frames, and locksets per design drawings provided by Viridian.� All debris (construction & hazardous) weights must be reported to VA Contracting Officer Representative (COR).� VA has option to retain some or all removed doors, closures, and locksets for attic stock.� Coordinate with VA COR. Remove caulk and paint from door frames as applicable.� Scraping and sanding must occur within a moveable containment barrier.� Plastic taped to ceiling and zipper doors are not acceptable for containment. Removal of ACM & lead as required. Paint and seal door frames. Paint will be Sherwin Williams low odor and color will be specified by VA COR when project is awarded. Doors and frames may need to be modified to fit. Doors are to be birch, plain sliced, cocoa bean in color. Doors are to be modified by a licensed technician as to retain UL fire rating. Installation of new doors, closures, and locksets per design drawings provided by Viridian are to match existing equipment in use at VANIHCS-Ft Wayne. No continuous hinges. Closures to be LCN 4040XP. Panic hardware to be Dorma F9500B, satin chrome in color. Door hardware to be lever handle, satin chrome in color, 7-pin cylinder core. Temporary ICRA partition walls are to be used along with HEPA negative air machines.� See drawing GI003 for details.� Plastic taped from ceiling or zip walls is not acceptable. All walls, floors, and ceiling will be repaired if damaged during demolition and construction and returned to pre-construction conditions with matching colors and finishes.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/496d68500439487e99c69e35ea3b303e/view)
 
Place of Performance
Address: Fort Wayne, IN 46805, USA
Zip Code: 46805
Country: USA
 
Record
SN06831661-F 20230916/230914230121 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.