Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 05, 2024 SAM #8074
SOURCES SOUGHT

99 -- Building 10 Modernization and Chiller Replacement

Notice Date
1/3/2024 8:25:56 AM
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
CDC OFFICE OF ACQUISITION SERVICES ATLANTA GA 30333 USA
 
ZIP Code
30333
 
Solicitation Number
75D301-24-SS-72912
 
Response Due
1/18/2024 2:00:00 PM
 
Archive Date
02/02/2024
 
Point of Contact
Patrick Winders, Phone: 7704882669
 
E-Mail Address
vxx6@cdc.gov
(vxx6@cdc.gov)
 
Description
THIS IS A SOURCES SOUGHT NOTICE. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME. The Centers for Disease Control and Prevention (CDC) will likely issue a solicitation, as a Request for Proposal (RFP), for design build construction services for a central plant modernization and chiller replacement at the CDC Roybal campus located at 1600 Clifton Rd., Atlanta, GA 30333 in calendar year 2024. CDC requests letters of interest from qualified SMALL AND LARGE BUSINESS GENERAL CONSTRUCTION CONTRACTORS THAT CAN PERFORM AS A PRIME GENERAL CONTRACTOR on the planned central plant modernization and chiller replacement in Atlanta, Georgia. By way of this Sources Sought, CDC intends to determine the extent of capable firms that are engaged in providing the general construction services described hereunder. Responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract. It is the responsibility of the interested parties to monitor this site for additional information pertaining to this notice. Response to this Request for Information is not mandatory for consideration in any subsequent Request for Proposal. The Modernization will include design build mechanical work including replacement of four existing 1,450 ton chillers with 1,800 ton chillers, replacement of eight cooling towers and four chilled water pumps.� Electrical work includes installation of two new Motor Control Centers (MCC), replacing medium voltage (MV) starters and recircuiting.� The project also involves, building automation systems (BAS), fire protection, architectural and structural work.� The required work involves a General Contractor providing complete for construction design documents and construction services, including, but not limited to: management and inspection services, bonds, insurance, CPM schedules, health and safety plan, quality control plan, product submittal development and review, develop required coordination drawings, construction administration services, security and logistic control, furnish tools, materials, equipment, labor and incidentals, safety review/inspections, quality control, coordinate all construction related work, test and inspections, commissioning, operational manuals, facilities maintenance training, record documents, warranties, and other related professional services. This procurement is anticipated to be unrestricted regarding business size. Interested contractors must have an active registration, including completion of the annual representations and certifications, in the System for Award Management (SAM) at http://sam.gov at the time of proposal submission in order to be eligible for award. Only Contractor firms and their major consultants/joint venture partners having offices within the continental United States will be considered for this procurement. The proposed project is anticipated to be a competitive, firm-fixed-price, construction contract procured in accordance with FAR Part 15, Contracting by Negotiation, under a Best Value-Tradeoff Process. The estimated magnitude of construction is $20 million. The North American Industry Classification System (NAICS) for this requirement is 236220 (Commercial and Intuitional Building Construction) Business Size Standard of $45 Million. Submission Instructions: Narrative shall be no longer than 8 pages. Comments will be shared within the Government and the Integrated Project Team but will otherwise be held in strict confidence. Should you respond to this Request for Information, please submit the following information: 1. Firm�s name, address, point of contact, phone number, and e-mail address, and capabilities. 2. Firm�s level of interest in competing on the solicitation when it is issued. 3. Firm�s Business Size � Large, Small, Small Disadvantaged Business (SDB), Service Disabled Veteran Owned Small Business (SDVOSB), Historically Underutilized Business Zones (HubZone), Woman Owned Small Business (WOSB), certified 8(a) firms, and SBA approved Mentor-Prot�g� firms. 4. Firm�s experience in successfully completed central plant renovation projects of similar size and dollar value range over $5,000,000.00. 5. Firm�s bonding level. THIS NOTICE IS NOT A REQUEST FOR PROPOSAL, QUOTE OR BID. It is one market research tool being utilized to determine the availability of potential qualified contractors in acquisition planning. In addition, this Request for Information is not to be considered as a commitment by the Government, nor will the Government pay for any information solicited or delivered. Response is not required for eligibility to participate in any subsequent Request for Proposal. Interested parties who consider themselves qualified to perform the above-listed requirement are invited to submit a response to this Request for Information no later than 5:00 P.M. Eastern Standard Time (EST) January 18, 2024. All responses under this Sources Sought must be emailed to Patrick Winders, vxx6@cdc.gov referencing the SAM Publication number 75D301-24-SS-72912. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. If you have any questions concerning this opportunity, please contact: Patrick Winders via email at vxx6@cdc.gov.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/150acd46c0a04fe1a7a8b0806f61264c/view)
 
Place of Performance
Address: Atlanta, GA 30333, USA
Zip Code: 30333
Country: USA
 
Record
SN06926229-F 20240105/240103230047 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers