SOLICITATION NOTICE
65 -- 4000 SYRINGE PUMP Name Brand or Equal To CS: Tracy Heath
- Notice Date
- 2/12/2024 9:00:03 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
- ZIP Code
- 98662
- Solicitation Number
- 36C26024Q0234
- Response Due
- 2/13/2024 3:00:00 PM
- Archive Date
- 03/14/2024
- Point of Contact
- Tracy Heath, Contract Specialist, Phone: 253-888-4903, Fax: None
- E-Mail Address
-
tracy.heath@va.gov
(tracy.heath@va.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Awardee
- null
- Description
- 36C26024Q0234 0001 Description of Amendment: The purpose of this amendment is to: update the salient characteristics for the software component. The two (2) bolded characteristics listed under software are not required and can be excluded. The quote due date is extended by one day and quotes are now due 02/13/2024 @ 15:00 PT. All other terms and conditions remain unchanged. Salient Characteristics: Infusion Pump: Accuracy +/- 2% Must be customizable with a design to help prevent medication errors and allow health care providers to send and receive medication delivery information efficiently. Capable of auto-detecting various syringe types and see, from 1mL to 60mL. Dimensions: 6.2 H x 10.5 W x 5.7 D. Moisture protection or fluid resistant Tested to EMI/EMC testing per IEC 60601-2-24 Rechargeable battery: minimum 400 charge cycle counts, capable of 10 hour run time AC power: 100-240 VAC, 50/60 Hz, 42 VA; Safety Call II- Type CF with Functional Earth Conductor Warranty: one year factory warranty with a warranty extension available Operating conditions: Temperature: 5 to 40 C (40 to 104 F) Relative Humidity: 20 to 95% non-condensing Ambient Pressure: 70 kPa to 106 kPa (10.2 psia to 15 4 psia) Storage and Transportation Conditions: Temperature: -20 to 50 C (-4 to 122 F) Relative Humidity: 20% to 95% non-condensing Ambient Pressure: 70 kPa to 106 kPa (10.2 psia to 15.4 psia) Software: Pharmguard Medication Safety Software Comprehensize and versatile drug libraries Flexible workflows Designed to support the varying needs in specialized care areas. Reports highlighting important issues and allow for drill down in areas needing attention. Enhanced patient/clinician safety Streamlined clinical workflows with infusion data near real-time (auto transfer infusion data to EHR) Rotating Pole Clamp: Rotating Pole clamp (45 and 90 degree)
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/e28b9b1d400b4b999f983edcc1ad0210/view)
- Place of Performance
- Address: Department of Veterans Affairs Mann-Grandstaff VA Medical Center 4815 N. Assembly St. Warehouse, Bldg. 14, Spokane 99205, USA
- Zip Code: 99205
- Country: USA
- Zip Code: 99205
- Record
- SN06963392-F 20240214/240212230050 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)