Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 16, 2024 SAM #8116
SOLICITATION NOTICE

Z -- RA/SA Motor Controls Project

Notice Date
2/14/2024 7:02:33 AM
 
Notice Type
Presolicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
PBS R5 ACQUISITION MANAGEMENT DIVISION CHICAGO IL 60604 USA
 
ZIP Code
60604
 
Solicitation Number
47PF0024R0039
 
Response Due
3/1/2024 1:00:00 PM
 
Archive Date
12/31/2024
 
Point of Contact
Roger Schulte, Phone: 2166452280, Martin L. Harris, Phone: 2174925041, Fax: 2174925046
 
E-Mail Address
roger.schulte@gsa.gov, martin.harris@gsa.gov
(roger.schulte@gsa.gov, martin.harris@gsa.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
THIS PROCUREMENT IS A TOTAL SMALL BUSINESS SET ASIDE BUSINESS CONCERNS ONLY The synopsis is for a pre-solicitation notification only. NO SOLICITATION IS ATTACHED. A SOLICITATION WILL BE POSTED ON OR ABOUT March 10, 2024 The General Services Administration (GSA) has a need to hire a contractor for Peck RA SA Motor Controls Project at the J.W Peck Federal Building 550 Main Street Cincinnati, Ohio 45202.� The project consists of the following:� 1. Replace the existing heating hot water coils for 3 of the existing dedicated outdoor air units. Existing piping and valves to be re-used. Pipe insulation to be replaced as necessary for coil�installation. 2. Replace the existing chilled water coils for 3 of the existing dedicated outdoor air handling units. Existing piping and valves to be re-used. Pipe insulation to be replaced as necessary for coil�installation. 3. Provide additional outside air system sensors to better control the outside air system (Munters�units). The new sensors will be integrated with the existing building automation system (BAS) to�open the dual duct VAV boxes when the spaces are occupied. Additional programming of the�existing BAS will be required. Additional re-programming of the BAS system to be provided to�allowing dual duct boxes to utilize their outside air systems to heat areas that need heat as�necessary. 4. Provide new controllers to replace the factory-supplied controllers for the Munters dedicated�outdoor air units. New controllers will be integrated with the existing Munters units and the�existing BAS. 5. Replace main air handler supply fan motors 1 and 2. General fan maintenance is to be included. 6. Replace main air handler return fan motor 1. General fan maintenance is to be included. The performance period is 84 calendar days upon receipt to Notice to Proceed. The anticipated award is on or about May 2024. The estimated construction cost range is between $1,000,000 and $5,000,000. The NAICS code is 238220 with a small business size standard of $19 million
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/04cb0d90c1114820866b9f53a50abf63/view)
 
Place of Performance
Address: Cincinnati, OH 45202, USA
Zip Code: 45202
Country: USA
 
Record
SN06965810-F 20240216/240214230053 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.