Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 17, 2024 SAM #8117
SOURCES SOUGHT

59 -- Sources Sought for Schneider Electric PowerLogic ION8650B, 64MB Memory Meter

Notice Date
2/15/2024 2:07:17 PM
 
Notice Type
Sources Sought
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
NAVFACSYSCOM PACIFIC JBPHH HI 96860-3134 USA
 
ZIP Code
96860-3134
 
Solicitation Number
N6274224SEPLM53
 
Response Due
2/29/2024 4:00:00 PM
 
Archive Date
03/15/2024
 
Point of Contact
Shaun Bissen, Phone: 8084717130, Erik Torngren, Phone: 8084746476
 
E-Mail Address
shaun.m.bissen.civ@us.navy.mil, erik.s.torngren.civ@us.navy.mil
(shaun.m.bissen.civ@us.navy.mil, erik.s.torngren.civ@us.navy.mil)
 
Description
Sources Sought � Schneider Electric PowerLogic ION8650B, 64MB Memory Meter Notice of intent to use a brand name product.� The Naval Facilities Engineering Systems Command, Pacific (NAVFAC Pacific) is performing a market survey to determine if other potential sources of supply can provide meters that have equal performance and listing/approval requirements to the Schneider Electric PowerLogic ION8650B, 64MB Memory Meter.� FY24 MCON Project P-541, Missile Integration Test Facility, NAVBASE Guam, Joint Region Marianas, Guam requires 1 meter with the following characteristics: a.� Fully compatible with existing Schnieder Power Logics ION enterprise control system platform servers in Building 3190. b.� Application: Revenue metering, cogeneration and IPP monitoring, compliance monitoring, power quality analysis, demand and power factor control, load curtailment, equipment monitoring and control; energy pulsing and totalization, instrument transformer correction and outage notification. c.� Type of measurement:� True rms 1024 samples per cycle. Measurement accuracy 0.1% Reading for current and voltage 0.1% Power �0.001 Hz 0.1% Power factor 0.1% Energy d.� Date update rate: 0.5 cycle or 1 second e.� Input-voltage characteristics 57V to 277V V L-N rms nominal voltage 600 V L-L rms (9s) maximum voltage 5M?/Phase impedance Inputs: V1, V2, V3, VREF f.� Input-current characteristics 1A, 2A, 5A and 10A rated nominal current 0.01-20A accuracy range 0.001-24A measurement range 500A rms for 1 second, non-recurring permissible overload Socket, 3W, 8VA/Phase, 3 Phase g.� Standard Power Supply: 120-277V, L-N RMS (-15%/+20%) 47-63Hz or 120-480V, L-L RMS (-15%/+20%) 47-63Hz h.� Auxiliary powered low voltage: AC: 65-120 (+/- 15%) VLN RMS, 47-63Hz DC: 80-160 (+/- 20%) VDC i.� Auxiliary powered high voltage: AC: 160-277 (+/- 20%) VLN RMS, 47-63Hz DC: 200-300 (+/- 20%) VDC j.� Digital Outputs: 4 (Form C) solid state relays (130V AC/200V DC) 50mA AC/DC, 1 (Form A) output k.� Digital Inputs: up to 3 self-excited, dry contact sensing inputs l.� Environmental: Operating Temperature: -40 Degree Celsius to 85 Degree Celsius Display Operating Range: -40 Degree Celsius to 70 Degree Celsius Storage Temperature: -40 Degree Celsius to 85 Degree Celsius Humidity Rating: 5% to 95% RH non-condensing Dielectric withstand: 2.5kV m.� Communication: RS-232/RS-485 port (COM1): 300-115,200 baud (RS-485 to 57,600 bps); Protocols: ION, Modbus/RTU/Mastering, DLMS, DNP 3.0, GPSTRUETIME/DATUM Internal modem port (COM2): 300-57,600 bps ANSI 12.18 Type Optical Port (COM3): up to 57,600 bps RS-485 (COM4): up to 57,600 baud, Modbus, direct connection to a PC or Modem Ethernet port: 10/100BASE-T, RJ45 connector, protocols: DNP, ION, Modbus/TCP/Mastering, IEC 61850 Ed.2 or 100BASE-FX multimode, male ST connectors, DLMS EtherGate: Up to 31 Slave devices via serial ports ModemGate: Up to 31 slave devices n. Memory: 64MB This notification is for market research purposes only to identify if other potential sources of supply can meet the requirements of the Government. This is not a request for proposals, quotes, or an invitation for bid. The intent of this notice is to identify other potential sources of this product. To be considered, please submit detailed technical data in order for the Government to conduct a comprehensive evaluation of your product to ensure compatibility with the existing system. In accordance with FAR 15.201(e), a response to this notice is not an offer and cannot be accepted by the Government to form a binding contract. The responder is solely responsible for the information it submits and any associated costs. The Government reserves the right to disregard any submittal that is incomplete or vague. Please do not submit company brochures. Please submit complete information via email to Mr. Shaun Bissen via electronic mail at shaun.m.bissen.civ@us.navy.mil no later than 29 February 2024 at 2:00 p.m. H.S.T. �Information received after the due date/time will not be considered. Any information provided to the Government in response to this RFI will become U.S. Government property and will not be returned. All proprietary or classified information will be treated appropriately.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/313f17e899114418a87bbfd62ca5d3d8/view)
 
Place of Performance
Address: GU, USA
Country: USA
 
Record
SN06968350-F 20240217/240215230059 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.