Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 21, 2024 SAM #8150
SOLICITATION NOTICE

65 -- PHILIPS DigitalDiagnost SKYPLATE

Notice Date
3/19/2024 10:44:05 AM
 
Notice Type
Presolicitation
 
NAICS
334517 — Irradiation Apparatus Manufacturing
 
Contracting Office
246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
 
ZIP Code
23667
 
Solicitation Number
36C24624Q0600
 
Response Due
3/27/2024 10:00:00 AM
 
Archive Date
04/26/2024
 
Point of Contact
Ronnie Gregory, Contract Specialist, Phone: 757-315-3932
 
E-Mail Address
Ronnie.Gregory@va.gov
(Ronnie.Gregory@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
This solicitation is a request for quotations (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01. This solicitation is issued as an Open Market, Service Disable Veteran Owned Small Business (SDVOSB) SET_ASIDE. The associated North American Industrial Classification System (NAICS) code for this procurement is 334517, with a small business size standard of 1000 Employees. The Richmond VA Medical Center, located at 1201 Broad Rock Blvd, Richmond, VA 23249 has requested to purchase a Brand Name Only PHILIPS SKYPLATE GRID direct replacement part to upgrade their current Philips DD X-ray system SKYPLATE GRID. This is a Brand Name Only Requirement. Salient Characteristics Functions to be performed. Wireless portable Grid plate accessory for the Philips DD 2.x and 3.x EZD, EZDFR 4.x and 5.x. Utilized for Diagnostic imaging of Veterans Will provide Axillary view of shoulder per radiologist and orthopedics Suitable for difficult projections or anatomy such as shoulder. Skull, c-spine views, and patella views of the knee Performance required. Must be able to do multiple positioning for lateral or oblique projections without having to move patient. Must provide optimal image quality while keeping radiation dose low, reducing radiation scatter, and improving image contrast. Wireless transmission of image data to Philips DD 2.x and 3.x EZD, EZDFR 4.x and 5.x. Must have rechargeable batteries capable of powering unit for standard imaging examinations. Essential physical characteristics; Dimensions (if applicable) Must be compatible to fit current X-ray rooms Philips DD 2.x and 3.x EZD, EZDFR 4.x and 5.x. Software that connects grid to Philips DD 2.x and 3.x EZD, EZDFR 4.x and 5.x. unit and other compatible units, to use the detector on current diagnostic x-ray rooms Must dust proof and able to be cleaned with liquid-based solutions. Must be light weight (maximum of three pounds) for everyday clinical use and reduce user fatigue. Must be 1 depth as to not interfere with critical equipment, cable, tubes, and catheters. Easily change out batteries without needing special tools to maintain proper workflow. Grid size must be 10 x 12 ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 1.00 EA DigitalDiagnost 4.x / C90 Upgrades 712084 LOCAL STOCK NUMBER: 712084 0002 1.00 EA SkyPlate Infrastructure Kit NRDN215 LOCAL STOCK NUMBER: NRDN215 0003 1.00 EA Upgrade SkyPlate Set Small NRDN218 LOCAL STOCK NUMBER: NRDN218 0004 1.00 EA Grid Portrait SkyPlate Small NRDN404 LOCAL STOCK NUMBER: NRDN404 The vendor shall be an OEM, authorized dealer, authorized distributor, or authorized reseller for the proposed medical supplies, medical equipment, and/or services contracts for maintenance of medical equipment (i.e. replacement parts), verified by an authorization letter or other documents from the OEM, such that the OEM s warranty and service are provided and maintained by the OEM.  All software licensing, warranty and service associated with the medical supplies, medical equipment, and/or services contracts for maintenance of medical equipment shall be in accordance with the OEM terms and conditions. The Government will award a contract resulting from this RFQ to the responsible offeror whose quote represents the lowest price acceptable for the government. Quotations shall be received no later than 1PM EST on March 27, 2024. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f) and will not be evaluated. Quotations shall be submitted via email to Ronnie Gregory at Ronnie.Gregory@va.gov.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/dd583ca1abc94ad8a0809fa5ab8a6ead/view)
 
Place of Performance
Address: Department of Veterans Affairs Richmond VA Medical Center 1201 Broad Rock Blvd, Richmond, VA 23249, USA
Zip Code: 23249
Country: USA
 
Record
SN07002077-F 20240321/240319230051 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.