Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 30, 2024 SAM #8159
SOLICITATION NOTICE

36 -- Industrial Commercial Laundry Equipment Lake City, FL

Notice Date
3/28/2024 3:47:42 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333310 —
 
Contracting Office
NAC LAUNDRY AND PACS Hines IL 60141 USA
 
ZIP Code
60141
 
Solicitation Number
36L79724Q0004
 
Response Due
4/5/2024 1:00:00 PM
 
Archive Date
07/13/2024
 
Point of Contact
Monique.Lara@va.gov, Monique Lara, Contract Specialist
 
E-Mail Address
Monique.Lara@va.gov
(Monique.Lara@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
Combined Synopsis Solicitation is hereby amended as follows: Provide answers to questions submitted by interested parties, Update to Addendum to 52.212-1 Instructions to Offerors Commercial Products and Commercial Services, Factor 2 - Space Utilization (Layout) and Monorail Process Flow, Incorporate Attachment A Statement of Work, and Incorporate Attachment B Technical Specifications _________________________________________________________________ Question 1. Please validate if the atmospheric vents connected to the new washer/extractors can be connected to the atmospheric vent currently servicing the existing Braun washer/extractors and routed out as a common vent through the roof. Answer 1. Yes, the atmospheric vents to the new washer extractors may be connected to the atmospheric vent currently servicing the existing washer extractors and routed out a common vent through the roof. Refer to the updated Statement of Work section 4.7.7. Question 2. Typically, an Uninterrupted Power Supply is not required for washer extractors. The inclusion of this requirement could significantly increase cost and scope of the project and provide limited operational benefit. Please validate if in this instance an Uninterrupted Power Supply is only a requirement for the Washer Control System? Answer 2. The Uninterrupted Power Supply (UPS) shall be installed for the Wash Control System. Refer to the updated Statement of Work section 5.4.5. Question 3. The existing trench that will service the new washer/extractors does not have an existing diamond plate trench cover or the supporting angle iron framework installed over the existing trench. The diamond plate trench covers are not mentioned in the solicitation, but are a needed item to support the operation of the equipment. Please validate if new diamond plate trench covers and the angle iron framework are to be installed over the entire length of the existing trench? Answer 3. Yes, new diamond plate trench covers, and the angle iron framework shall be installed over the entire length of the existing trench. Diamond plate covers shall be easily removed for cleaning. The supplemental requirement is reflected in line items 0001 and 0002 of the updated Technical Specifications.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/c7bda562a13b4fe0a8931b2b7b622d7b/view)
 
Place of Performance
Address: Lake City VA Medical Center Building 74 619 South Marion Avenue Lake City, FL 32025-5808, USA
 
Record
SN07012686-F 20240330/240328230044 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.