SOURCES SOUGHT
54 -- Containerized Office Space and Gym
- Notice Date
- 5/20/2024 7:18:26 PM
- Notice Type
- Sources Sought
- NAICS
- 332312
— Fabricated Structural Metal Manufacturing
- Contracting Office
- 0413 AQ HQ CONTRACT AUG FORT SHAFTER HI 96858-5100 USA
- ZIP Code
- 96858-5100
- Solicitation Number
- W91QVP-24-Q-1199
- Response Due
- 5/28/2024 2:59:00 PM
- Archive Date
- 06/12/2024
- Point of Contact
- SSG Chia Chen, Phone: 8087875581, SFC Christiaan Lawes, Phone: 8087878863
- E-Mail Address
-
chia.h.chen.mil@army.mil, christiaan.d.lawes.mil@army.mil
(chia.h.chen.mil@army.mil, christiaan.d.lawes.mil@army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- 1.3 Scope: The Contractor shall provide non-personal service(s) encompassing the procurement, delivery, installation, setup and maintenance of the following facilities: Three (3) 16� by 40� office containers containing: - One (1) 25,000 BTU AC Unit per container. - Ensure all installations are compatible with Guam's electrical system. Voltage used will be 120/240 volts and frequency will be set at 60 hz. - No less than 6 ceiling mounted LEDS with a minimum lumen output of 75 watts Adequate lighting fixtures - Two (2) doors, situated at the front and back of each container. - Four (4) windows per container for natural illumination. - Ten (10) electrical outlets distributed across the container (2 ports each). - One (1) Ethernet Hub per container (8 ports each) for connectivity. - Typhoon-rated construction to withstand adverse weather conditions. - The structures must comply with the latest version of the International Building Code (IBC) for typhoon resistance and the local Guam Building Code requirements for wind loads Page 2 of 28 - All structures must be designed and constructed to withstand sustained wind speeds of up to 200 mph, equivalent to Category 5 typhoon conditions. - All fasteners, connectors, and bracing systems must be rated for high-wind applications and meet or exceed the ASTM standards for structural integrity. - The contractor shall perform structural leveling and stabilization for all office containers. To include, foundation and base preparation, precision leveling, and an anchoring system. Additionally, the Contractor shall provide routine maintenance services for each Office Container on a quarterly basis, including inspections, repairs, and replacements as necessary to ensure continued functionality and compliance with standards. The maintenance will be provided 48 months after the completion of the instillation of all four structures. One (1) Quonset hut gym at 30�x30�x10�containing: - 8 LED High Bay Lights . - Two (2) bay doors for accessibility measuring at 8�x10� on each end wall - Two (2) Industrial 7� ceiling fans - Typhoon-rated construction to ensure durability in harsh weather conditions. - The structures must comply with the latest version of the International Building Code (IBC) for typhoon resistance and the local Guam Building Code requirements for wind loads - All structures must be designed and constructed to withstand sustained wind speeds of up to 200 mph, equivalent to Category 5 typhoon conditions. - All fasteners, connectors, and bracing systems must be rated for high-wind applications and meet or exceed the ASTM standards for structural integrity. - The contractor shall perform structural leveling and stabilization for all office containers. To include, foundation and base preparation, precision leveling, and an anchoring system. - Twelve (12) electrical outlets distributed across the trailer (2 ports each). Furthermore, the Contractor shall conduct routine maintenance services for the Quonset hut gym trailer on a quarterly basis, encompassing inspections, repairs, and replacements to maintain optimal performance and compliance with requirements. The maintenance will be provided 48 months after the completion of the instillation of all four structures. 1.5.6 Place of Performance: The work to be performed under this contract will be performed at Site Excalibur.�Grid coordinates WGS 84 55P 02655 14991. Naval Base Guam in Santa Rita, Guam.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/ab1bdfaadcb94be2b5a6c4a6f5ea2127/view)
- Place of Performance
- Address: Santa Rita, GU, USA
- Country: USA
- Country: USA
- Record
- SN07070849-F 20240522/240520230057 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |