Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 06, 2024 SAM #8227
SOURCES SOUGHT

70 -- Network Equipment

Notice Date
6/4/2024 7:38:23 AM
 
Notice Type
Sources Sought
 
NAICS
334419 — Other Electronic Component Manufacturing
 
Contracting Office
NSWC PHILADELPHIA DIV PHILADELPHIA PA 19112-1403 USA
 
ZIP Code
19112-1403
 
Solicitation Number
PD-51-0026A
 
Response Due
6/14/2024 7:00:00 AM
 
Archive Date
06/29/2024
 
Point of Contact
Karen Morris, Phone: 4452270069
 
E-Mail Address
karen.morris@navy.mil
(karen.morris@navy.mil)
 
Description
SOURCES SOUGHT NOTICE FOR NAVAL SURFACE WARFARE CENTER PHILADELPHIA DIVISION (NSWCPD) SUBJECT:� Network Equipment THIS SOURCES SOUGHT IS NOT A REQUEST FOR PROPOSAL.� It is a market research tool being used to determine potential and eligible firms capable of providing the supplies/services described herein prior to determining the method of acquisition. SOURCES SOUGHT DATE: 4 June 2024 CONTRACTING OFFICE ADDRESS: N64498 NAICS CODE: 334419 CLASSIFICATION CODE (PSC/FSC): 7B20 INCUBMENT:� Not applicable PREVIOUS STRATEGY: Not Applicable TECHNICAL CODE:� Code 515 ANTICIPATED AWARD DATE:� 30 August 2024 RESPONSE DATE: 14 June 2024 ANTICIPATED SET-ASIDE:� Not Applicable CONTACT POINT(S):� Karen Morris Contract Type � A firm fixed priced contract is anticipated.� Period of Performance Delivery will be six months from the date of the award. Scope � The Naval Surface Warfare Center, Philadelphia Division (NSWC-PD) Division 515 is seeking sources for networking hardware is required to support LHD/A MCS Tech Refresh. Industrial Fiber Optic Ethernet Backbone Layer-3 Switch� Product Description:� Full gigabit ethernet backbone switch,� Internal redundant power supply,� advanced Layer 3 HiOS features,�� Multicast routing,� 52 Ports:� 4 fixed ports: 4x 1/2.5/10 GE SFP+� 48x FE/GE ports expandable with four(4) media module slots� 12x FE/GE ports per module, modular, field-replaceable� Hot-swappable fans� Power Supply:�� Modular, field-replaceable� Nominal power of voltage supply: 300 W� Operating Voltage: 100-240 V AC� Power consumption: 6 W� Dimensions:� WxHxD: 480 mm x 88 mm x 445 mm� Mounting: 19� control cabinet� Protection Class: IP20� Temperature:� Operating temperature: 0-+60 �C� Storage/transport temperature: -40-+70 �C� Relative humidity (non-condensing): 10-95 %� Power Requirements:� Operating Voltage: PSU unit input: 100 - 240 V AC� Power consumption: 80 W (incl. SFP transceivers + 1 PSU + Fan module)� Interface:� V.24 interface: 1 x RJ45 socket� SD-card slot: 1 x to connect auto-configuration adapter ACA31 (SD)� USB interface: 1 x USB to connect auto-configuration adapter ACA22-USB� Software:� Switching: Independent VLAN Learning, Fast Aging, Static Unicast/Multicast Address Entries, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, IP Ingress DiffServ Classification and Policing, IP Egress DiffServ Classification and Policing, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), Protocol-based VLAN, VLAN Unaware Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, MAC-based VLAN, IP subnet-based VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN, Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Layer 2 Loop Protection,� Redundancy: HIPER-Ring (Ring Switch), HIPER-Ring over Link Aggregation, Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), MRP over Link Aggregation, Redundant Network Coupling, Sub Ring Manager, RSTP 802.1D-2004 (IEC62439-1), MSTP (802.1Q), RSTP Guards, VRRP, VRRP Tracking, HiVRRP (VRRP enhancements),� Management: Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, V.24, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, DNS Client, OPC-UA Server,� Diagnostics: Management Address Conflict Detection, MAC Notification, Signal Contact, Device Status Indication, TCPDump, LEDs, Syslog, Persistent Logging on ACA, Email Notification, Port Monitoring with Auto-Disable, Link Flap Detection, Overload Detection, Duplex Mismatch Detection, Link Speed and Duplex Monitoring, RMON (1,2,3,9), Port Mirroring 1:1, Port Mirroring 8:1, Port Mirroring N:1, RSPAN, SFLOW, VLAN Mirroring, Port Mirroring N:2, System Information, Self-Tests on Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump, Snapshot Configuration Feature,� Configuration: Automatic Configuration Undo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), BOOTP/DHCP Client with Auto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN, AutoConfiguration Adapter ACA31 (SD card), AutoConfiguration Adapter ACA21/22 (USB), HiDiscovery, DHCP Relay with Option 82, Command Line Interface (CLI), CLI Scripting, Full-featured MIB Support, Web-based Management, Context-sensitive Help� Security: MAC-based Port Security, Port-based Access Control with 802.1X, Guest/unauthenticated VLAN, Integrated Authentication Server (IAS), RADIUS VLAN Assignment, RADIUS Policy Assignment, Multi-Client Authentication per Port, MAC Authentication Bypass, DHCP Snooping, IP Source Guard, Dynamic ARP Inspection, Denial-of-Service Prevention, LDAP, Ingress MAC-based ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, Time-based ACL, VLAN-based ACL, Ingress VLAN-based ACL, Egress VLAN-based ACL, ACL Flow-based Limiting, Access to Management restricted by VLAN, Device Security Indication, Audit Trail, CLI Logging, HTTPS Certificate Management, Restricted Management Access, Appropriate Use Banner, Configurable Password Policy, Configurable Number of Login Attempts, SNMP Logging, Multiple Privilege Levels, Local User Management, Remote Authentication via RADIUS, User Account Locking, Password change on first login� Time synchronization: PTPv2 Transparent Clock two-step, PTPv2 Boundary Clock, Buffered Real Time Clock, SNTP Client, SNTP Server� Miscellaneous: Manual Cable Crossing, Port Power Down� Routing: IP/UDP Helper, Full Wire-Speed Routing, Port-based Router Interfaces, VLAN-based Router Interfaces, Loopback Interface, ICMP Filter, Net-directed Broadcasts, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Equal Cost Multiple Path (ECMP), Static Unicast Routing, Proxy ARP, Static Route Tracking, IGMP v1/v2/v3, IGMP Proxy (Multicast Routing), DVMRP, PIM-DM (RFC3973), PIM-SM / SSM (RFC4601)� Multicast routing: DVMRP, PIM-DM (RFC3973), PIM-SM / SSM (RFC4601)� Managed Industrial Switch for DIN Rail� Product Description:� Managed Industrial Switch for DIN Rail, fanless design All Gigabit type� 12 Ports in total:�� 8x 10/100/1000BASE TX / RJ45,�� 4x 100/1000Mbit/s fiber ; � 1. Uplink: 2 x SFP Slot (100/1000 Mbit/s);�� 2. Uplink: 2 x SFP Slot (100/1000 Mbit/s)� Dimensions:� WxHxD: 73 mm x 138 mm x 115 mm� Mounting: DIN Rail� Protection Class: IP30� Weight: 570 g� Housing: PC-ABS� Temperature:� Operating temperature: 0-+60 �C� Storage/transport temperature: -40-+70 �C� Relative humidity (non-condensing): 1- 95 %� Power Requirements:� Operating Voltage: 2 x 12 VDC� Power consumption: 11 W� Power output in BTU (IT)/h 38� Interface:� Power supply/signaling contact: 1 x plug-in terminal block, 6-pin� Digital Input: 1 x plug-in terminal block, 2-pin� Local Management and Device Replacement: USB-C� Software:� Switching: Independent VLAN Learning, Fast Aging, Static Unicast/Multicast Address Entries, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), GARP VLAN Registration Protocol (GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP)� Redundancy: HIPER-Ring (Ring Switch), Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), Redundant Network Coupling, RSTP 802.1D-2004 (IEC62439-1), RSTP Guards,� Management: Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, IPv6 Management, OPC UA Server,� Diagnostics: Management Address Conflict Detection, MAC Notification, Signal Contact, Device Status Indication, TCPDump, LEDs, Syslog, Persistent Logging on ACA, Port Monitoring with Auto-Disable, Link Flap Detection, Overload Detection, Duplex Mismatch Detection, Link Speed and Duplex Monitoring, RMON (1,2,3,9), Port Mirroring 1:1, Port Mirroring 8:1, Port Mirroring N:1, Port Mirroring N:2, System Information, Self-Tests on Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump,� Configuration: Automatic Configuration Undo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), Backup config on a remote server when saving, Clear config but keep IP settings, BOOTP/DHCP Client with Auto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN, AutoConfiguration Adapter ACA21/22 (USB), HiDiscovery, USB-C Management support, Command Line Interface (CLI), CLI Scripting, CLI script handling over ENVM at boot, Full-featured MIB Support, Context-sensitive Help, HTML5 based Management,� Security: MAC-based Port Security, Port-based Access Control with 802.1X, Guest/unauthenticated VLAN, Integrated Authentication Server (IAS), RADIUS VLAN Assignment, Denial-of-Service Prevention, DoS Prevention Drop Counter, VLAN-based ACL, Ingress VLAN-based ACL, Basic ACL, Access to Management restricted by VLAN, Device Security Indication, Audit Trail, CLI Logging, HTTPS Certificate Management, Restricted Management Access, Appropriate Use Banner, Configurable Password Policy, Configurable Number of Login Attempts, SNMP Logging, Multiple Privilege Levels, Local User Management, Remote Authentication via RADIUS, User Account Locking, Password change on first login� Time synchronization: PTPv2 Transparent Clock two-step, PTPv2 Boundary Clock, BC with Up to 8 Sync / s, 802.1AS, Buffered Real Time Clock, SNTP Client, SNTP Server TSN 802.1Qbv Support� Industrial Profiles: EtherNet/IP Protocol, IEC61850 Protocol (MMS Server, Switch Model), Modbus TCP, PROFINET Protocol� Miscellaneous: Digital IO Management, Manual Cable Crossing, Port Power Down� Capability Statements: Interested businesses are invited to submit capability statements, not to exceed five double spaced, single-sided pages in length, demonstrating their ability to fulfill this requirement.� Capability Statements must address, at a minimum the following: Section 1: Introduction.� Identify the Sources Sought Number and Title Section 2: Corporate Description.� Name of Company and address Ownership, including whether:� Small, Small Disadvantaged Business (SDB), 8(a), Women-Owned Small Business (WOSB), HUBZone, or Service Disabled Veteran-Owned Small Business (SDVOSB) Points of contact, including: Name, title, phone, and e-mail address CAGE Code and DUNS Number �(1) A complete description of the offeror�s capabilities (including technical, program management, prototyping, etc.) related experience, facilities, techniques, or unique combination of factors that would directly relate to the Government�s objectives., (2) The qualifications, capabilities, and experiences of Contractor employees, who would be available to support this effort. Section 2. Past/Current Performance.� Provide one (1) example of prior/current corporate experience performing efforts of similar size and scope within the last three years, including contract number, organization supported, indication of whether as a prime or subcontractor, contract values, Government point of contact with current telephone number, and a brief description of how the referenced contract relates to requirement described. Note:� The requested information is for planning purposes and does not constitute a commitment, implied or otherwise, that a procurement action will be issued nor will the Government pay for the information solicited.� All information and data received in response to this sources sought marked or designated a corporate proprietary information will be fully protected and held in strict confidence. Note: No telephone responses will be accepted.� No contractor response received after the advertised due date and time will be accepted.� No exceptions to this receipt deadline will be granted under any circumstances.� Questions or comments must be submitted via email.� Responses must be received no later than 10AM EST on 14 June 2024 by e-mail to karen.l.morris49.civ@us.navy.mil. Milestones � It is anticipated that procurement milestones will occur on or around the following dates: Set Aside Determination/Synopsis Issued: 4 June 2024 Solicitation Issued:� 24 June 2024� Solicitation Closed:� 10 July 2024 Award Date:� 30 August 2024�
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/00449f3d9f9e4299b734f3f226a923ba/view)
 
Place of Performance
Address: Philadelphia, PA 19112, USA
Zip Code: 19112
Country: USA
 
Record
SN07086269-F 20240606/240604230123 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers