SOLICITATION NOTICE
Z -- Upgrade Fire Alarm System 583-26-221
- Notice Date
- 1/31/2025 8:15:49 AM
- Notice Type
- Solicitation
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- 250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
- ZIP Code
- 45428
- Solicitation Number
- 36C25025B0009
- Response Due
- 2/11/2025 7:00:00 AM
- Archive Date
- 03/13/2025
- Point of Contact
- Tiffany A Rausch, Contract Specialist
- E-Mail Address
-
Tiffany.Rausch@va.gov
(Tiffany.Rausch@va.gov)
- Awardee
- null
- Description
- RFI Questions and Responses In accordance with the VA's Technical Information Library, QUALIFICATIONS AND SCOPE OF SERVICES PROJECT FIRE PROTECTION ENGINEER, June 21, 2021, the services of a fire protection engineer is required for all projects that include the addition, reconfiguration, or elimination of a fire protection system. It is very unusual to see a VA construction project replacing an entire campus fire alarm system without a design prepared by, or with the involvement of, a fire protection engineer. Is there a design available for this project? If so, who is the fire protection engineer of record for the design of this project? If there is no design, is this a design-build construction project that will require the services of a fire protection engineer? This project focuses on replacing existing obsolete fire alarm system equipment in its original location with current industry standard equipment, and is not intended to add, eliminate, or even reconfigure the existing system in terms of moving components and devices from their location. Therefore, the services of a FPE are not required for this project. Knowledgeable fire protection contractors with the involvement of NICET certified technicians should be able to complete this project. Does the 19 page as-built set provided include all the buildings at 1481 West 10th Street (1,5,6,19,21,22,23,24)? The as-built drawings detail Building 1 only. Device counts for the other buildings at West 10th street can be obtained from the other included attachments such as the document FIRE ALARM DEVICE LOCATION LIST . Bid documents provided do not appear to show the parking garage. Can you provide? a. Drawings b. Device counts Parking garage drawings are provided, see attachment RLR VAMC Parking Garage. Part 2 Arch Struct MEP.Corrected F . Bid documents provided do not appear to show the Cold Springs Road buildings (7,9,42,43). Can you provide? a. Drawings b. Device counts c. Control panel brand and model. Fire protection drawing for Building 7 provided, see attachment Building 7-CSR-Fire Protection . Hand recorded fire alarm layout drawing provided as attachment Build. #43_Coumadin Clinic-Fire Alarm Layout . The Technical Requirements section references to project bid drawings, are there additional drawings that are missing? This section references all the attachments listed in Section VII: A-G of the SOW. The only additional drawings are those provided in response to RFI s. All known applicable drawings have been included with this solicitation.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/5609867d8b7a414bb91862a752c9942b/view)
- Record
- SN07329414-F 20250202/250131230110 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |