Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 09, 2025 SAM #8657
SOLICITATION NOTICE

66 -- FLUKE T5-1000

Notice Date
8/7/2025 10:48:07 AM
 
Notice Type
Presolicitation
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
DLA MARITIME - NORFOLK PORTSMOUTH VA 23709-5000 USA
 
ZIP Code
23709-5000
 
Solicitation Number
SPMYM125Q0137
 
Response Due
8/13/2025 9:00:00 AM
 
Archive Date
08/28/2025
 
Point of Contact
CURTIS DOUGLAS, Phone: 7572785058
 
E-Mail Address
curtis.douglas@dla.mil
(curtis.douglas@dla.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY) intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically Acceptable (LPTA) Evaluation Factors for the item listed below. The required item is for commercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart 12.6, as supplemented with the additional information included in this notice. The Contract Line Item (CLIN) is as follows: ITEM NO. DESCRIPTION QTY U/I UNIT PRICE TOTAL 0001 FLUKE T5-1000 ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER MODEL#: FLUKE T5-H5-1AC II KIT REF P/N 2PY98 100 EA Determined by vendors Determined by vendors T5-600/T5-1000 Electrical Tester Parts and Service The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the TS-600/TS-1000 Electrical Tester Instruction Sheet. To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com. Specifications Accuracy is specified for one year after calibration, at 18 �C to 28 �C (64 �F to 82 �F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows: ::!;([ % of reading] + [number of least significant digits]) Temperature coefficient of 0.1 x (specified accuracy)/ �C for 28 �C (82.4 �F) Serial Numbers 79560000 and Above General Specifications Calibration One-year calibration cycle. Maximum Voltage Between any Terminal and Earth Ground TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2 TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2 Maximum Voltage Between Current Fork and Earth Ground TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.) Temperature Operating: -10 �C to +50 �C (14 �F to 122 �F); Storage: -30 �C to +60 �C (-22 �F to +140 �F) Altitude Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft) Relative Humidity O o/o to 95 %, 5 �C to 30 �C (41 �F to 86�F); o o/o to 75 %, 30 �C to 40 �C (86 �F to 104 �F); O o/o to 45 %, 40 �C to 50 �C (104 �F to 122 �F) Battery Type and Life AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride Shock, Vibration 1 m drop at -10 �C to + 50 �C (14 �F to 122 �F) per ANSI/ISA-S82.0l-1994 and EN 61010-1 1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum) Surge Protection TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010 Enclosure Rating IP 52 per IEC 60529, no vacuum applied General Specifications (continued) RF Field Specification 0.5 % full scale + (specified accuracy) at 3 V/m Safety Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995. EMC EN 61326 Certifications CE <ti� ??S�IF,? C In accordance with IEC 61010-1 54CJ Resolution and Accuracy Function TS-600 Range TS-1000 Range Resolution Accuracy v 600 V rms 1000 V rms lV :!(1.5 % + 2 digits) v 600V 1000V lV :!(1% + 1 digit) ~A 100.0A 100.0A 0.lA :!(3 % + 3 digits) n 10000 1000 0 10 :!(1o/o + 2 digits) Input Characteristics Function Input Protection Input impedance (nomial T5-600 TS-1000 v 600 V rms 1000 V rms 1 MO, <100 pF ac-coupled v 600 V rms 1000 V rms 1 MO, <100 pF n 600 V rms 1000 V rms n Open Circuit Test Voltage Short Circuit Current 1.65 V de (nominal) <600 �A CAT Ill protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings. CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service. Serial Numbers 79559999 and Below General Specifications Calibration One-year calibration cycle. Maximum Voltage Between any Terminal and Earth Ground TS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill Temperature Operating: -10 �C to +50 �C (14 �F to 122 �F); Storage: -30 �C to +60 �C (-22 �F to +140 �F) Altitude Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft) Relative Humidity 0 o/o to 95 %, 5 �C to 30 �C (41 �F to 86�F); 0 o/o to 75 %, 30 �C to 40 �c (86 �F to 104 �F); 0 o/o to 45 %, 40 �c to 50 �C (104 �F to 122 �F) Battery Type and Life AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride T5-600/T5-1000 Electrical Tester General Specifications (continued) Shock, Vibration 1 m drop at 15 �C to 35 �c (59 �F to 95 �F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993. Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum) Surge Protection T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09 Enclosure Rating IP 52 per IEC 60529, no vacuum applied RF Field Specification 0.5 % full scale + (specified accuracy) at 3 V/m Safety Complies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993. EMC EN 50081-1, EN 50082-1 Certifications ( E c@us ct �� Resolution and Accuracy Function TS-600 Range TS-1000 Range Resolution Accuracy v 600 V rms 1000 V rms lV :!(1.5 % + 2 digits) v 600V 1000V lV :!(1% + 1 digit) A 100.0A 100.0A 0.lA :!(3 % + 3 digits) n 10000 10000 10 :!(1% + 2 digits) Input Characteristics Function Input Protection Input impedance (nomial T5-600 T5-1000 v 600 V rms 1000 V rms 1 MO, <100 pF ac-coupled v 600 V rms 1000 V rms 1 MO, <100 pF n 600 V rms 1000 V rms n Open Circuit Test Voltage Short Circuit Current 2.4 V de (nominal) <600 �A CAT 111 protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings. CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service. Cleaning the Tester ?Warning To avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester's case, never use solvents on the tester. If the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester. The requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025. The anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only. THE SOLICITATION IS NOT YET AVAILABLE. The solicitation number is SPMYM125Q0137, and it is expected to be available on or about 07 AUG 2025 and posted to SAM.gov, https://sam.gov/ Quotes will be due by 12:00 PM EST on 13 AUG 2025. Responses to the solicitation notice shall be emailed to the attention of Curtis Douglas at Curtis.douglas@dla.mil . Please make sure that the solicitation number (SPMYM125Q0137) is included in the subject line of any email correspondence. Emails without subject lines will not be read because of security issues. Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror's to access solicitation documents posted. Prospective Offeror's should also register on the interested vendor list under SPMYM125Q0137. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed. All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the solicitation, except for awards to foreign vendors for work to be performed outside the United States. Lack of registration in the SAM database will make an offeror ineligible for award. Offerors may obtain information on registration and annual confirmation requirements by calling 1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in accordance with the solicitation, dates and procedures. Please direct all questions regarding this requirement to Curtis Douglas at Curtis.douglas@dla.mil
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/af8a37e1bb004629aa1bd31efb5d32d1/view)
 
Place of Performance
Address: Portsmouth, VA 23709, USA
Zip Code: 23709
Country: USA
 
Record
SN07542448-F 20250809/250807230100 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.