Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 17, 2025 SAM #8665
SOLICITATION NOTICE

41 -- 692-25-3-1613-0016 EMPI Funded Portable Chiller

Notice Date
8/15/2025 3:43:42 PM
 
Notice Type
Solicitation
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98661 USA
 
ZIP Code
98661
 
Solicitation Number
36C26025Q0717
 
Response Due
8/22/2025 12:00:00 PM
 
Archive Date
09/21/2025
 
Point of Contact
Meredith F Valentine, Contract Specialist
 
E-Mail Address
Meredith.Valentine@va.gov
(Meredith.Valentine@va.gov)
 
Awardee
null
 
Description
Page 1 of 2 SF30 BLOCK 14 CONTINUATION PAGE Amendment 0001 for RFQ 36C26025Q0717 is being issued for the following:� Disseminate the following questions and answers submitted by interested parties. What is the application being cooled? The application is building chilled water systems of various sizes. The portable chiller (RFQ ed at a certain tonnage) may be used at various locations on our facility, with varying loads, depending on need. The idea is that when one of our permanent building chillers goes off-line, we can pull this trailer up to it and use our in situ chilled water taps and by-pass valves to transfer the building s chilled water system to the portable. The portable needs to be 55-60 nominal tons to cover our chillers in that size range. We have a smaller one that we use for smaller needs. Will this be a mobile-mounted chiller, and how often will the system be moved? The answer to this question is contained in the SOW (which mentions portable, and the trailer size required; the trailer is also provided by the responder of this RFQ, as the trailer contains all the contents.) As far as the question how often will the system be moved , that depends on when we need it. But an annual guestimate is about 5-10 moves annually. What flow rate and pressure are required for the process, and what leaving fluid temperature should be maintained? The chiller needs to meet all of the following: Flow rate, 2.6 GPM per ton minimum ( so 143- 160 GPM), pressure is 30 psi, chilled water leaving temp = 55 degrees F (+/-) All other terms and conditions remain unchanged.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/0ea0edbe55b74ac3a964b40e0bb0d2f0/view)
 
Record
SN07553328-F 20250817/250815230047 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.