Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 17, 2025 SAM #8665
SOURCES SOUGHT

J -- Repair Boilers #2 and #3

Notice Date
8/15/2025 9:12:59 AM
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98661 USA
 
ZIP Code
98661
 
Solicitation Number
36C26025Q0851
 
Response Due
9/8/2025 12:00:00 PM
 
Archive Date
09/18/2025
 
Point of Contact
Meredith Valentine, Contract Specialist
 
E-Mail Address
meredith.valentine@va.gov
(meredith.valentine@va.gov)
 
Awardee
null
 
Description
This is a SOURCES SOUGHT NOTICE only in support of the Veterans Affairs (VA) s Southern Oregon Rehabilitation Center and Clinics (VA SORCC) located in White City, OR. This sources sought is for market research purposes only to determine the availability of potential businesses who are interested and capable of meeting the requirements for the project summarized below. Responses may be used to determine acquisition strategy for a potential future acquisition but will not be the sole market research method used. Interested parties are invited to provide a response that includes the following information by email only to Meredith.valentine@va.gov and Helen.Woods@va.gov by no later than 1200 Pacific on 08 September 2025. Response shall include: Company Name, address, point of contact, and SAM UEI. Note- companies are not required to be SAM registered to respond to this notice but are highly encouraged to do so as SAM registration is mandatory to submit a response if a solicitation is issued for this requirement to be considered for an award. List of any additional information your firm would need to be able to submit an accurate and complete offer if a solicitation were issued for this project. A capability statement of no more than two (2) pages succinctly describing how your company is capable of completing this specific project s requirements. Generalized statements that do not show specific capability to meet requirements will not be used to determine a set-aside. List any concerns your company has with providing domestic end-products/made in USA items to meet requirements to comply with Buy American and/or Trade Agreement Act requirements or awareness of any challenges to meeting these requirements. If your company is a SDVOSB and/or VOSB, indicate if your company anticipates any challenges complying with the limitations on subcontracting for general construction outlined on VA.gov under VAAR 852.219-75(JAN 2023)(DEVIATION). NAICS code is currently anticipated as 238220. The product service code will be J045. If you disagree, please include your recommendation in your response. Project Summary: The consultant shall supply all labor, material and equipment to: Remove Burner from Burner Mounting Ring, Remove Burner Blast Tube from Burner, Remove Windbox Cover from right hand side of Blast Tube, Replace any Broken Stripped or damaged studs, Replace Windbox cover with new Fender and Lock Washers and install Brass Nuts, Remove Burner Mounting Ring from Boiler, Replace broken and stripped studs on the mounting ring of the Morrison Tube for #2 Boiler. Re-install Burner Mounting Ring with new finder washers and lock washers and install new brass nuts. Repair refractory damaged in Burner Mounting ring removal. Re-install Burner Mounting Ring with new Gaskets, replace Refractory seal for Burner Mounting ring. Re-install Burner Blast Tube with new gaskets, reattach burner and re-install all piping and electrical connections removed during disassembly. Ensure Burner fires on both Natural Gas and #2 Fuel Oil. Provide any refractory curing requirements. Additional Studs to be Replaced on #3 Boiler windbox access cover while onsite. Work to be performed at the Southern Oregon Rehabilitation Center and Clinics White City Oregon VAMC Boiler Plant. The work shall be documented in a full report of findings and recommendations. All Welding must be performed by or Supervised by a Licensed Boiler Maker. All Electrical work to be performed by a Licensed Electrician. Copies of licensing and factory training will be required prior to starting work. Work will be done on the Equipment listed below. #2 Boiler Superior Model 7-X-1250 National Board # 19030 Year Built 2019 #2 Burner Webster Cyclonetic Model # JBEX5C-75-K-(****).M.(**)-MA-NFPS-85 Serial # 130478A-01 #3 Burner Webster Cyclonetic Model # JBEX5C-75-K-(****).M.(**)-MA-NFPS-85 Serial # 130478A-02 The period of performance is estimated at 30-45 days, but a final period of performance will be provided in a solicitation if one is issued.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/3be18505f6b14696ab66596e9be59230/view)
 
Place of Performance
Address: White City SORCC 8495 Crater Lake Hwy, White City, OR 97503
 
Record
SN07553725-F 20250817/250815230050 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |