Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 06, 2025 SAM #8746
SOURCES SOUGHT

J -- Altoona VAMC | PM&R - Reverse Osmosis

Notice Date
11/4/2025 12:20:34 PM
 
Notice Type
Sources Sought
 
NAICS
811210 —
 
Contracting Office
244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
 
ZIP Code
15215
 
Solicitation Number
36C24426Q0079
 
Response Due
11/14/2025 7:00:00 AM
 
Archive Date
01/13/2026
 
Point of Contact
Emily Hall, Contract Specialist, Phone: 412-791-3009
 
E-Mail Address
emily.hall5@va.gov
(emily.hall5@va.gov)
 
Awardee
null
 
Description
This is a SOURCES SOUGHT NOTICE only. Responses to this notice will be used for information and planning purposes. No quotes are being requested or accepted at this time with this notice. The Department of Veteran s Affairs, Altoona Medical Center, Altoona, PA 16602, has a requirement for Preventative Maintenance and Repair (PM&R) for Ameriwater brand SPD Reverse Osmosis equipment. The North American Industry Classification System (NAICS) code being considered for this procurement is 811210, Electronic Precision and Equipment Repair and Maintenance, and the Product Service Code (PSC) is J064 Maintenance, Repair, and Rebuilding Equipment-Water Purification and Sewage Treatment Equipment. The Small Business Size Standard is $34 million. Responses to this notice should include the following: Company name SAM UEI Company s address Point of Contact Information (i.e., title, phone number, and email address) Company s capability to meet this requirement and any pertinent information which demonstrates the company s ability to meet the above requirement. GSA Federal Supply Schedule contract number or other applicable contract vehicle contract number, if within scope of this effort (if applicable). Company s type of business (small or large) Socio-economic status If applicable, Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Business (VOSB) must be verified in www.VetBiz.gov. Responses should provide enough information to determine if the vendor can comply with the limitations on subcontracting as defined in VAAR 852.219-74 and all applicable CFR references where applicable. All responses shall be in writing via email no later than 10:00 am (ET) November 14, 2025, to Emily Hall at emily.hall5@va.gov. Facsimile or telephone responses will not be accepted. There will be no question-and-answer period for this sources sought. Simply responding as an interested party does constitute your company as a source. Offeror must provide the above requested information. After reviewing the responses to this sources sought notice, a solicitation announcement may be published on the SAM or GSA website in the near future. Responses to this sources sought announcement are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the forthcoming solicitation announcement, in addition to responding to this sources sought notice. All interested parties must be registered with System for Award Management (SAM) at https://www.sam.gov in order to be eligible for award of Government contracts. Statement of Need Background: The Altoona VA Medical Center wishes to procure a PM&R service contractor for SPD Reverse Osmosis equipment. All necessary labor must be performed by an authorized Ameriwater Service Provider capable of providing materials, equipment, parts and travel to perform inspections on the AMERIWATER ROS 800 GPD REVERSE OSMOSIS SYSTEM with Deionozer and Storage Tank (00HC-2050) at the James E. Van Xandt VA Medical Center, 2907 Pleasant Valley Boulevard, Altoona, PA 16602. PERIOD OF PERFORMANCE: Base Plus 4 one-year option periods Base Year: 12/03/2025-12/02/2026 Option Year 1: 12/03/2026-12/02/2027 Option Year 2: 12/03/2027-12/02/2028 Option Year 3: 12/03/2028-12/02/2029 Option Year 4: 12/03/2029 12/02/2030 QUARTERLY SERVICE: -Inspect System for Leaks -Verify Proper Functioning of RO Gauges &Instrumentation -Monitor RO Membrane Performance -Verify Proper Functioning of Storage Tank System/ Level Controls -Verify Proper Functioning of Distribution Pump System -Verify Proper Functioning of Anti-Scalant Feed System -Replace two Ameriwater Carbon Block Filter Cartridges 2.5"" x 20""10 micron -Check and Fill Antiscalant. Use customer stock to refill. -RO Cleaning/Disinfection SEMI-ANNUAL SERVICE TO INCLUDE: -Minncare disinfection of the silex unit prior to replacement of (2) DI Sacks -Disinfect the silex housings before installing the new sacks -Replace DI Packs (send out exhausted sacks to be regenerated for the next service. Includes replacement certificates) *To be completed alongside a quarterly service* ANNUAL SERVICE TO INCLUDE: -Disinfection of Storage Tank -Disinfection of 55 gallon storage tank *To be completed alongside a quarterly service* PARTS INCLUDED: -AMERIWATER CHLOR PLUS CARBON CARTRIDGES- CASE OF 6 (PN: 124009) - AMERIWATER, PT-401, ANTI-SCALANT, 4 X 1 GALLON (PN: 153796) - (TWO) AMERIWATER DI-2101S, STARTUP STANDARD RECIRC. RESIN PACK, .5 CU.FT. - (TWO) AMERIWATER DI-2101C, REGENERATION CERTIFICATE, STANDARD DI, .5 CU.FT.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/ece65c7259174b488f724f6001797be6/view)
 
Place of Performance
Address: Department of Veterans Affairs Altoona VA Medcial Center 2907 Pleasant Valley Boulevard, Altoona 16602-4305, USA
Zip Code: 16602-4305
Country: USA
 
Record
SN07635111-F 20251106/251104230036 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.