Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 10, 2026 SAM #8901
SOLICITATION NOTICE

J -- AMENDMENT 0001 TO RFQ 36C24526Q0401 UPLOADED ANSWERS TO RFIS AND GENERATOR DESCRIPTIONS LOUIS A JOHNSON VAMC

Notice Date
4/8/2026 4:44:20 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
245-NETWORK CONTRACT OFFICE 5 (36C245) LINTHICUM MD 21090 USA
 
ZIP Code
21090
 
Solicitation Number
36C24526Q0401
 
Response Due
4/14/2026 7:00:00 AM
 
Archive Date
05/14/2026
 
Point of Contact
Bill Pratt, Contracting Officer, Phone: 410-642-2411
 
E-Mail Address
Billie.Pratt@va.gov
(Billie.Pratt@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business Set Aside
 
Awardee
null
 
Description
GENSET #1 GENSET #2 GENSET #3 Manufacturer/Make/Year: Caterpillar Caterpillar Kato Model No: SR-4 C32 500SS9D Serial/Order No: 6NA01031 G1G00044 7319 Load Rating: (Emergency/Standby/Prime) 1000 kva 1250 kva 625KVA Power Factor: .8 .8 .8 Frequency: 60 Hertz 60 Hertz 60 hertz Load in Amperage: 1000 amps 1000 amps 87 Output Voltage: 480 480 volts 4160 volts Phase: 3-phase 3-phase 3-phase Building: Bld 17 Bld 17 Bld 17 Location (Area/Room): Generator room Generator Rm Generator Rm GENSET #4 GENSET #5 (portable) Manufacturer/Make/Year: Kohler Baldor Model No: 100RE0ZJF TS225-3J Serial/Order No: 3346GMJL0001 P1205240012 Load Rating: (Emergency/Standby/Prime) 128 kva 225 kva Power Factor: .8 .8 Frequency: 60 Hertz 60 Hertz Load in Amperage: 153 amps 625 amps Output Voltage: 480 480 volts Phase: 3-phase 3-phase Building: Parking Garage Grounds Location (Area/Room): Parking Garage Grounds (portable) Who will be responsible for the generator maintenance (monthly, quarterly, semi, annual, & triennial) an when was the last time the annual maintenance was completed? Mountaineer Generator. When was the last annual load bank testing conducted? � � � � � � � � � � � � � 3/28/26. Does the KATO 500kW (625KVA) 4160v generator have an integrated load bank? NO
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/d6429cb7f6494e21ae4d88bdfd8a735b/view)
 
Place of Performance
Address: Department of Veterans Affairs Louis A Johnson VA Medical Center 1 Medical Ctr Dr, Clarksburg, WV 26301, USA
Zip Code: 26301
Country: USA
 
Record
SN07771583-F 20260410/260408230041 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.