Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 30, 2026 SAM #8951
SOURCES SOUGHT

58 -- Sources Sought, High-Precision Mechanical Positioning Pan/Tilt Systems for Edwards Air Force Base (AFB)

Notice Date
5/28/2026 10:48:13 AM
 
Notice Type
Sources Sought
 
NAICS
334220 — Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
 
Contracting Office
FA9302 AFTC PZZ EDWARDS AFB CA 93524-1185 USA
 
ZIP Code
93524-1185
 
Solicitation Number
F1S0AY6134A001
 
Response Due
6/6/2026 1:00:00 PM
 
Archive Date
06/21/2026
 
Point of Contact
Josiah Broadway, Terence Vickers, Phone: 6612772232
 
E-Mail Address
josiah.broadway@us.af.mil, terence.vickers@us.af.mil
(josiah.broadway@us.af.mil, terence.vickers@us.af.mil)
 
Description
Request for Information (RFI) Subject: High-Precision Mechanical Positioning Pan/Tilt Systems for Edwards Air Force Base (AFB) 1. Introduction & Purpose (BLUF) The purpose of this Request for Information (RFI) is to conduct market research to identify potential sources capable of providing heavy-duty, high-precision Pan/Tilt units and associated integrated components. This RFI is for planning purposes only and does not constitute a Request for Proposal (RFP) or a promise to issue an RFP in the future. 2. Background The 420th Combined Test Force at Edwards AFB requires high-precision mechanical positioning units (pan/tilts) to support various sensor payloads while maintaining full data and command-link integrity with the established network. This equipment serves as a critical node within the current Telemetry infrastructure. The Government requires solutions that not only meet strict physical and environmental performance specifications but also satisfy stringent cybersecurity protocols to avoid unacceptable mission delays associated with new baseline First Article Testing and Risk Management Framework (RMF) certifications. 3. Scope & Requirements The Government is seeking industry input on Commercial-Off-The-Shelf (COTS) solutions capable of meeting the following baseline requirements: Requirement CategoryDescription of Required CapabilityCybersecurity & ATO IntegrationMANDATORY: Must be capable of immediate integration into the installation�s existing NGDATS Authority to Operate (ATO). The solution must not trigger new baseline First Article Testing or a new Risk Management Framework (RMF) cycle.Wireless ProhibitionThe system CANNOT have any wireless technology embedded or active. This is critical for Range security and ATO compliance.Data TransmissionMust provide video and control over a simplex fiber (single-mode) network utilizing standard IP and Pelco D protocols.Mechanical & EnvironmentalMust support inverted mounting (upside down) with a specific design that prevents water pooling and internal seepage. All components must be weatherproof and withstand extreme harsh range environments (up to 131�F, wind, rain, freezing) and shock/vibration events (e.g., sonic booms).Speed & PrecisionMust be capable of movement speeds of at least 30�/second with a position resolution of 0.05� or better, ensuring smooth and precise control. 4. Information Requested from Industry Interested parties are requested to submit a capability statement addressing their ability to meet the stringent requirements outlined above. Responses should specifically address the following: Company Overview: Name, CAGE code, UEI, and business size/socioeconomic status. Technical Approach: A description of the proposed COTS equipment and how it meets the specific mechanical and environmental constraints (specifically addressing the inverted mounting and extreme temperature requirements). Compliance Verification: Confirmation that the proposed system strictly operates without wireless technology and can immediately integrate into the existing NGDATS ATO without triggering a 12-month delay for new RMF testing. Scalability & Control: Details on how the system manages multi-node control using multiple conventional joysticks simultaneously on the same network. 5. Submission Instructions Responses to this RFI should be submitted via email to the Primary Point of Contact (POC) no later than 4:00 PM EST on June 6, 2026. Primary Point of Contact: Name: Josiah Broadway Title: Contract Specialist Email: josiah.broadway@us.af.mil Secondary Point of Contact: Name: Terence Vickers Title: Contracting Officer Email: terence.vickers@us.af.mil
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/c0cffbd2055647b79e147b6e46b4bcb1/view)
 
Place of Performance
Address: Edwards, CA 93524, USA
Zip Code: 93524
Country: USA
 
Record
SN07833467-F 20260530/260528230058 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.