COMMERCE BUSINESS DAILY ISSUE OF JUNE 9,1995 PSA#1364Westinghouse Hanford Company, 2355 Stevens Drive, Post Office Box 1970,
Attn: MSIN R2-71, Richland, Washington 99352 46 -- WATER DECONTAMINATION FOR WASTE ENCAPSULATION AND STORAGE
FACILITY POC J.B. Calhoun (509) 373-0656. Westinghouse Hanford Company
(WHC) is seeking interested sources to provide technical support and
services for water decontamination of Hanford's Waste Encapsulation and
Storage Facility (WESF) capsule storage pools. These temporary services
must be available for the unlikely possibility of an event resulting
from failure of one cesium137 or strontium 90 capsule or the
catastrophic failure of all 1300 cesium and 600 strontium capsules.
Sources must demonstrate their technical ability to design and develop
a portable emergency response Ion Exchange system which is capable to
the structural requirements of the Hanford site WESF, previous
demonstrations of decontaminating water contaminated with radioactive
materials, the ability to develop recovery procedures meeting State and
Federal requirements and the expertise to train facility personnel to
follow these procedures during required annual live testing
demonstrations of the equipment, provided services must include the
capability to recover and remove contaminated materials for disposal
away from the Hanford site. Possible failure parameters must provide
for a range from single capsule of 40,000 curies to catastrophic
failure of 75,000,000 curies. Expressions of interest with statements
of capabilities, including requests for possible FY 96 RFP packages may
be sent via facsimile on (509) 373-2280, Attention J.B. Calhoun. No
compensation will be provided for efforts associated with preparing
submittals and interested sources may not be notified of the results of
the information submitted. (157) Loren Data Corp. http://www.ld.com (SYN# 0351 19950608\46-0001.SOL)
46 - Water Purification and Sewage Treatment Equipment Index Page
|
|