COMMERCE BUSINESS DAILY ISSUE OF AUGUST 18,1995 PSA#1413US Army Armament And Chemical Acquisition And Logistics Activity,
(ACALA) Attn: AMSTA-AC-PCC (WW9), Rock Island, IL 61299-7630 41 -- FAN, VANE AXIAL SOL DAAE20-95R0248 DUE 100695 POC Contact the
Contract Specialist: Mary Robbins (309)782-4372, procuring Contracting
Officer is: DRU Johnson (309)782-3575. 4140-01-325-6972, part number
12553839. Fan, vane axial, 16 curved blades, single width. 10.000 in.
Nominal. Diameter: 6.100 in. Nominal. Material: Steel overall. Drive
type: Direct. Rotation direction for which designed: Counterclockwise.
Air flow rate:4000.0 cubic feet per minute nominal. Static pressure at
specified air flow rate: 2.5 in. Of water. Flow direction: Inward.
Mounting facility type and quantity: 2 slot and 2 unthreaded hole. III
end item identification: Goes 2350-01-305-0028 M109a6. Mfr source
con-trolling reference: 12553839. Rate: 2.5 in. Of water. Flow
direc-tion: Inward. Mounting facility type and quantity: 2 slot and 2
UN threaded hole. III end item identification: Goes 2350-01-305-0028
M109a6. Requirements are 50 EA fan, vane axial. For use on them109a6
Paladin SPH. FOB is destination. MIL-I-45208 inspection criteria
required. First article test is required. Estimated issue date of this
Solicitation is 090695. Effective 1 Oct 94 AMCCOM Sep arated into two
new commands; the Industrial Operation Command (IOC) and the
Acquisition Chemical Armament Logistics Activity (ACALA). It is
imperative that special attention be Given when AD-dressing requests
for solicitations and BIDS/O ffers. Failure to properly address
requests for solicitations in accordance with this CBD notice will
result in non-receipt of the Solicitation P ackage. Failure to properly
address BIDS/offers in accordance with Sol icitation instructions may
result in a late bid which cannot be consider Ed. Written, FAX or
electronic requests for Solicitation packages are accepted. NO
telephone requests will be honored. Re quests for copies of this
Solicitation should include your commer cial and Government Entity
(CAGE) (if a CAGE Code has been assigned to you) along with your name,
address, datafax number, and solic-itation number. The FAX number for
requests is (309) 782-4728. Electronic requests may be accepted
through the AMCCOM Acquisition Information System (AAIS). All AMCCOM
solicitations are available for viewing/downloading, in addition to
procurement history, via the AAIS. The AAIS can be accessed
electronically, 24 hours a Day, utilizing a MODEM set to dial (309)
782-7648. Terminal emulation should be VT100, NO parity, 8 data bits
and 1 stop bit. Once con-nected, enter ''AAIS'' at the ''login''
prompt. At the ''password'' prompt depress the ''enter'' key. If
electronic means is not possible, procurement history will be provided
telephonically at (309)782-8094 on a limited basis. (0228) Loren Data Corp. http://www.ld.com (SYN# 0257 19950817\41-0001.SOL)
41 - Refrigeration, Air Condition and Air Circulating Equipment Index Page
|
|