COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 12,1996 PSA#1529Commander, Naval Air Warfare Center Weapons Division, Code 220000D, 1
Administration Circle, China Lake, CA 93555-6001 49 -- FORCE MEASUREMENT SYSTEM (FMS) SOL N68936-96-R-0111 DUE 032996
POC Erica Freeman, Contract Specialist, (619) 939-5427. 1 each,
including associated hardware and calibration system. The contractor
shall supply installation procedures, and shall align and certify the
system at the Plume Measurement Capability Facility (PMCF) site at the
Skytop Test Complex at the Naval Air Warfare Center Weapons Division,
China Lake, CA. The FMS shall not exceed 9 feet by 9 feet by 3 feet
tall and shall be capable of withstanding the following loads produced
by the static firing of a solid rocket motor: 80,000 pound force
maximum in the axial direction (x-axis), the side (horizontal)
direction (y-axis), the vertical direction (z-axis), and 450,000
foot-pound moment maximum in the x-z plane, y-z plane and any position
of rotation about the z-axis. The FMS shall measure a 30,000 pound
force thrust rocket motor mounted 15 feet above the orthogonal axis
anywhere in an axial-vertical plane with the following accuracy: axial
thrust, 3000-30,000 pound force plus or minus 0.15% of Full Scale;
vertical thrust, 3000-30,000 pound force plus or minus 0.25% of Full
Scale; side thrust, 3000-30,000 pound force plus or minus 0.25% of Full
Scale; vector magnitude 3000-30,000 pound force plus or minus 0.25% of
full scale; vector angle, plus or minus .25 degrees; pitch moment,
1000-5,000 foot-pound plus or minus 0.5% of Full Scale. The FMS shall
provide for the upgrade possibility to a range of 1000-80,000 pound
force at a distance such that the moment at the orthogonal axis of the
stand does not exceed 450,000 foot-pounds. The calibration system
shall be built-in with no set-up required to perform an In-frame
calibration and shall be able to calibrate within one hour prior and
within one hour after each test firing. Delivered FOB destination,
calibrated, and aligned at the Skytop Test Complex, 365 days after
contract award. All responsible sources may submit an offer which shall
be considered by the agency. (0039) Loren Data Corp. http://www.ld.com (SYN# 0158 19960209\49-0003.SOL)