Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MAY 14,1996 PSA#1594

56 Contracting Squadron, 14100 W Eagle Street, Luke AFB AZ, 85309- 1217

65 -- NURSE CALL SYSTEM SOL F02604-96Q1313 DUE 053096 POC Contact Julia Schmitz, Buyer, (602) 856-6348 X237 or John Castle, Contracting Officer, (602) 856-7168. System, Nurse Call, Provide and install a complete and operation- al Nurse Call System in Ward 3B, Medical Surgical Unit (MSU) of the hospital. The system shall match and interface with the ex- isting Executone Care/Com II-E nurse call system located in Ward 3A, Special Care Unit (SCU). Nurse Call System shall be a micro- processor controlled desk type station with audio-visual call re- gistration. Have the capability for direct access of up to six- ty stations providing immediate two-way communication. A hand- set shall provide confidential conversations. The nurse control station shall have a reset button to permit termination of a call originating at the Nurse Control Station without hanging up the handset. The unit shall be Executone, Care/Com II-E or Approved or equal. Nurse call station shall have sixty station keys with with call indicators, six zone page keys, one in-use indicator, one patient call indicator, one talk/listen key, one incoming vol- ume control and one reset key, a solid state amplifier with an output power of 3 to 5 watts, input and output impedance shall be for 45 ohm lines. Frequency response shall be peaked for maximum voice articulation. Nurse call single patient stations shall be installed in Stryker cabinet style headwall units that will be installed simultaneously. Nurse call work shall be coordinated with headwall project. Units will be installed in center cabinet but will have remote patient stations to enable patient communic- ation with cabinet doors closed. The station units shall be con- trolled by the system microprocessor and shall have excellent voice pickup sensitivity. Removal of the cordset shall trigger staff assist call or normal call with a selectable switch. The patient station shall have staff assist functions. The speaker microphone shall havean impedance of 45 ohms to match the system. Nurse call single patient stations shall be provided with patient bedside controls. Patient controls (pillow speakers) shall inter- face with nurse call system and overhead patient light. Overhead light switch shall also be installed in the center of the patient location. Provide and install new cable from Nurse Call Station to each patient station. Provide all conduit, cable, pull boxes, fire stops, hardware and connecting devices for a complete and functional connection. Equipment will come with two copies of operators and technical service manuals, to include electrical schematics and parts list, full warranty equal to that of manu- facturer or supplier, but not less than standard One Year for for government equipment. Code Blue Stations: Shall be installed as shown on the drawings and shall be part of the nurse call sta- tion. Code blue alarm activation at each patient bed location shall activate the code blue alarm at the Central Nurse Call Sta- tion and the Emergency Room on the first floor. The contractor may use existing cable to interface the nurse station with the Emergency Room annuciation panel. Provide any additional wire, conduit, pull boxes, fire stops, hardware and connective devices for a complete functional system. Storage and Protection of Mat- erials: The contractor is responsible for storage and safekeeping of all materials to be used in this work. Workmanship: Work will be performed by a licensed bonded contractor. Systems: All new equipment systems shall come with two copies of operator and tech- nical services manuals to include electrical schematics, wiring diagrams and repair parts listing. Guarantee: The equipment furnished under this award to be shall be of hospital grade and guaranteed against defective materials, design and workmanship for the full warranty time which is standard with the manufacturer and supplier, but in no case, less than one year from the date of acceptance. Upon receipt of notice from the Government of failure of any part of the guaranteed equipment, during the guarantee period, the affected part of parts shall be replaced promptly with new parts at the expense of, and by the contractor. The work will be located at Luke AFB, Bldg 1130, Main Hospital, Ward 3B MSU. A site visit is required by vendor for awareness of general and local conditions that may affect the cost of contract performance to the extent that the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award.Normal work hours are between 0700 and 1630, Monday through Friday, excluding federal holidays. The nature of the hospital mission may require the contractor to work evenings and weekends at no additional cost to the Government. Clean up: The contractor will remove all debris, scrap, and other foreign matter from the job site daily and dispose of it off the military installation in accordance with federal, state and local standards. Government dumpsters will not be used for contractor disposal. Special Working Conditions: During the project, the government will occupy existing facilities. The contractor shall not restric access to the facility and shall coordinate work with the govern- ment representative to minimize conflict and to facilitate usage. The contractor shall perform the work so as to minimize conflicts and not interfere with ongoing operations. The contractor will coordinate all work and power outages through the Facility Manage- ment Office. The contractor will comply with regulations govern- ing the operation of the facility, Occupational Safety and Health Association (OSHA), National Electric Code (NEC) and National Fire Protection Association (NFPA). The contractor will confine cont- ract materials, equipment and personnel to the building and section currently affected by the contract. All combustible waste accumu- lated during the working day shall be disposed of daily and under no circumstances will it be allowed to accumulate into a dangerous situation. Protection of Owners Property and Personnel: Damage of any nature caused by this work shall be repaired or damaged proper- ty will be replaced at no expense to the government. If the contr- actor has not satisfactorily repaired or replaced the damaged pro- perty, the government reserves the right to make necessary correc- tions. The contractor shall reimburse the owner for consequential damages and for all materials and labor used for the corrections. Contractor will keep access, drives, fire lanes and doors clear at all times. All individuals for site visit are required to contact the Facility Management, Bldg 1130, Room R-03, Luke AFB, AZ 85309, (602) 856-7550. (This is a request for quote, not a solicitation). All quotes must be faxed in no later than 30 May 96, 4:30PM Mount- ain Standard Time. Arizona does not observe daylight savings time (0131)

Loren Data Corp. http://www.ld.com (SYN# 0361 19960513\65-0002.SOL)


65 - Medical, Dental and Veterinary Equipment and Supplies Index Page