COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 26,1996 PSA#1749Directorate Of Contracting/Oo-Alc Pko, 6038 Aspen Avenue Bldg 1289 Ne,
Hill air Force Base, Ut 84056-5000 C -- A&E ENVIROMENTAL SERVICES SOL F42650-97-R-A056 POC For copy,
Solicitation packages not available,,, For additional information
contact Sharon Price/Pkoe/[801]777-4799 A&E Environmental Services at
US Air Force facilities to include Hill AFB UT, Little Mountain Test
Annex UT, Utah Training Range and other facilities associated with the
Air Force mission. For additional information, contact Sharon K. Price
at 801-777-4799 or FAX 801-777-0632. 1. CONTRACT INFORMATION.
Indefinite Delivery/Indefinite Quantity Contracts for A&E environmental
services. The basic award period for the contract will be for one year
from the date of contract award and will contain four one year
options. The SIC code is 8744 (Size Standard 500). The award of six
contracts is contemplated. Up to four contracts will be unrestricted,
one contract will be set-aside for 8(a) firms, one contract will be
set-aside for small business firms. If technically qualified firms for
the set-aside portions of this acquisition cannot be identified, the
set-aside portions may revert to unrestricted acquisitions. The
anticipated amount of this requirement for all contracts awarded for
the basic period plus all options is estimated at $48,000,000. 2.
PROJECT INFORMATION. Firms shall be multi-disciplined in the
environmental engineering field. All contract work must comply with
federal, state, and local environmental laws and regulations. Typical
services required include but are not limited to: (1) remedial designs
for environmental remedies including site visits and investigations,
construction drawings, technical specifications cost estimates and
design analysis; (2) construction supervision and inspection of
environmental design projects; (3) treatability studies and field
investigations; (4) preliminary assessments, site investigations,
remedial investigations, feasibility studies; (5) technical
environmental assessments for proposed actions; (6) technical studies
and designs for air pollution control, water pollution control,
pollution prevention, etc. 3. SELECTION CRITERIA. The selection
criteria are listed below in descending order of importance. (1)
Professional qualifications, certifications, and specialized experience
of team members (including first tier subcontractors/consultants)
necessary for satisfactory performance of each type of service listed.
(2) Specialized experience and competence, recent experience (within
the last three years), and anticipated future capabilities of the firm
(including first tier subcontractors/consultants) in performing the
types of services listyed. The staff shall be familiar with
environmental laws, regulations, and issues. The firm shall have
professionals that are registered in the State of Utah. The
professional classifications required include but are not limited to:
engineers, geologists, hydrologists, hydrogeologists, chemists,
toxicologists, and industrial hygienists. The firm shall also have on
staff professional, technical, and support staff necessary to
accomplish the services listed. (3) Capacity and availability of key
staff to accomplish the work in the required time and the ability of
them to work on several projects simultaneously. (4) Past performance
on similar environmental contracts with government agencies and public
industry in terms of cost control, quality of work and compliance with
performance schedules. The contractor shall include appropriate
contract numbers and points of contact. (5) Location in the general
geographical area of the project and knowledge of the locality of the
project, availability of A&E staff to meet frequently with Air Force
personnel, regulatory agencies, and others in the Environmental
Management Directorate at Hill AFB. The firm shall have the ability to
mobilize staff to project sites on relatively short notice. Volume of
DoD contracts awarded in the last 12 months. 4. SUBMISSION
REQUIREMENTS: See Note 24 for general submission requirements.
Interested firms having the capabilities to perform this work must
submit four copies of SF 254, and four two copies of SF 255 to
OO-ALC/EMX, ATTN: Dr. Bob James, 7274 Wardleigh Road, Hill AFB UT
84056-5137. To be considered, all submittals must be receivednot later
than 2:00PM. MST, 21 Jan 97. Solicitation number is for identification
purposes only. Solicitation packages (specifications, plans, bidders'
list, etc.) are not available. This is not a Request for Proposal. See
Notes 2, 24. (0355) Loren Data Corp. http://www.ld.com (SYN# 0024 19961226\C-0007.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|