COMMERCE BUSINESS DAILY ISSUE OF MARCH 11,1998 PSA#2049Directorate of Contracting, Uniformed Services University of the Health
Sciences, Rm A1040c, 4301 Jones Bridge Road, Bethesda, MD 20814-4799 N -- INSTALLATION OF A BARRIER TO PREVENT CONTAMINATION OF TRANSGENIC
ANIMALS. SOL MDA905-98-R-0009 DUE 032098 POC Sally Ward, Contract
Specialist, 301-295-3067; James Geiser, CO, 301-295-3845 The Uniformed
Services University of the Health Sciences, Department of Defense
Medical School, in Bethesda, MD requires the installation of a barrier
within the central animal facility to prevent contamination of
transgenic animals. Award will be made on a brand-name (BioBubble,
Inc.) or equal basis. The acquisition will be made as a Small Business
set aside and will be commercial off-the-shelf. Specifications will
include the following: 1) airlock -- Skin: 16-20 mil, optically clear,
hospital grade vinyl; Filtration: UL Class 1, High Efficiency
Particulate Air Filters, Frame: 1-1/4 inch diameter aircraft-grade
aluminum tubing; Air Changes: 100 or more per hour; Dual inlet blower
3-6 amp/60 Hz/ w/pre-filter; 600-800 CFM air flow; Unit shall have
vinyl strip doors; Power Unit will sit off to one side and will pump
HEPA filtered air; Airlock will make aproximately 100 air changes per
hour; System must be capable of running 24 hours per day; Must be
capable of positive or negative air pressure; 2) airshowers -- Skin:
16-20 mil, optically clear, hospital grade vinyl; Filtration: UL Class
1, High Efficiency Particulate Air filters; Frame: 1-1/4 inch diameter
aircraft-grade aluminum tubing; air changes: 100 or more per hour; Dual
inlet blower 3-6 amp/60 Hz/ w/pre-filter; 600-800 CFM air flow; Size:
2 feet 5 inches wide, 18 inches deep x 54 inches to top of HEPA filter,
to be made flush with ceiling; 1 each protective tubing; will include:
aluminum framework, constructed of aircraft grade aluminum tubing; 3)
Air Curtain -- Skin: 16-20 mil, optically clear, hospital grade vinyl,
Filtration: UL Class 1, High Efficiency Particulate Air filters; Frame:
1-1/4 inch diameter aircraft-grade aluminum tubing; Air Changes: 100 or
more per hour; Dual inlet blower 3-6 amp/60 Hz/ w/pre-filter; 600-800
CFM air flow; unit shall have vinyl sidewalls and vinyl strip doors;
Power unit will sit off to one side and will pump HEPA filtered air;
Airlock will make approximately 100 air changes per hour; System must
be capableof running 24 hours per day. All responsible sources may
request a copy of the request for proposal in writing or by facsimile
(301) 295-1716. RFP will be released approximately 3/10/98. (0068) Loren Data Corp. http://www.ld.com (SYN# 0064 19980311\N-0001.SOL)